Department of Cardiovascular Surgery and Cardiology, Houston Methodist DeBakey Heart and Vascular Center, Houston, TX, USA.
Citations 13
Seven-year outcomes after surgical aortic valve replacement with a stented bovine pericardial bioprosthesis in over 1100 patients: a prospective multicentre analysis
Abstract OBJECTIVES Safety, efficacy and durability are important considerations when selecting a bioprosthesis for aortic valve replacement (AVR). This study assessed 7-year clinical outcomes and haemodynamic performance of the Avalus bioprosthesis. METHODS Patients indicated for surgical AVR were enrolled in this prospective, nonrandomized trial, conducted across 39 sites globally. The primary end-point of this analysis was freedom from surgical explant or percutaneous valve-in-valve reintervention due to structural valve deterioration (SVD) at 7 years of follow-up, determined using Kaplan–Meier (KM) analysis. We also evaluated a composite end-point of SVD and/or severe haemodynamic dysfunction requiring reintervention. Survival, valve-related safety events and haemodynamic performance were assessed. Deaths and safety events were adjudicated by an independent clinical events committee. RESULTS A total of 1132 patients underwent surgical AVR. Mean age was 70 years; 854 patients (75%) were men. The mean STS risk of mortality was 2.0 ± 1.4%, and 659 patients (58%) had a New York Heart Association classification of I/II. One or more concomitant procedures were performed in 577 patients (51%). At 7 years, the Kaplan–Meier rate of freedom from SVD/severe haemodynamic dysfunction requiring reintervention was 1.2% (0.5–2.5%) with no cases adjudicated as SVD. The survival rate was 82.6% (79.5–85.0%). The KM event rate was 5.7% (4.3–7.7%) for reintervention, 6.3% (4.9–8.3%) for endocarditis and 0.4% (0.1–1.1%) for valve thrombosis. Mean aortic gradient, dimensionless velocity index and effective orifice area were 13.8 ± 5.9 mmHg, 0.42 ± 0.09 and 1.99 ± 0.53 cm2, respectively. CONCLUSIONS This analysis demonstrated excellent durability of the Avalus valve with good clinical outcomes and stable haemodynamic performance through 7 years of follow-up.
Myocardial Blood Flow Reserve, Microvascular Coronary Health, and Myocardial Remodeling in Patients With Aortic Stenosis
Background Coronary microvascular function and hemodynamics may play a role in coronary circulation and myocardial remodeling in patients with aortic stenosis (AS). We aimed to evaluate the relationship between myocardial blood flow and myocardial function in patients with AS, no AS, and aortic valve sclerosis. Methods and Results We included consecutive patients who had resting transthoracic echocardiography and clinically indicated positron emission tomography myocardial perfusion imaging to capture their left ventricular ejection fraction, global longitudinal strain (GLS), and myocardial flow reserve (MFR). The primary outcome was major adverse cardiovascular event (all‐cause mortality, myocardial infarction, or late revascularization). There were 2778 patients (208 with aortic sclerosis, 39 with prosthetic aortic valve, 2406 with no AS, and 54, 49, and 22 with mild, moderate, and severe AS, respectively). Increasing AS severity was associated with impaired MFR ( P <0.001) and GLS ( P <0.001), even when perfusion was normal. Statistically significant associations were noted between MFR and GLS, MFR and left ventricular ejection fraction, and MFR and left ventricular ejection fraction reserve. After a median follow‐up of 349 (interquartile range, 116–662) days, 4 (7.4%), 5 (10.2%), and 6 (27.3%) patients experienced a major adverse cardiovascular event in the mild, moderate, and severe AS groups, respectively. In a matched‐control analysis, patients with mild‐to‐moderate AS had higher rates of impaired MFR (52.9% versus 39.9%; P =0.048) and major adverse cardiovascular event (11.8% versus 3.0%; P =0.002). Conclusions Despite lack of ischemia, as severity of AS increased, MFR decreased and GLS worsened, reflecting worse coronary microvascular health and myocardial remodeling. Positron emission tomography–derived MFR showed a significant independent correlation with left ventricular ejection fraction and GLS. Patients with prosthetic aortic valve showed a high prevalence of impaired MFR.
Impact of aortic valve replacement in symptomatic low-risk patients with less than severe aortic stenosis
Objective To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). Methods Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0<aortic valve area (AVA)<1.5 cm2, 3.0<peak velocity<4.0 m/s and 20≤mean gradient (MG) <40 mm Hg). Clinical outcomes were reported through 2 years. Results Moderately-severe AS was identified in 113 out of 1414 patients (8%). Baseline AVA was 1.1±0.1 cm2, peak velocity 3.7±0.2 m/s, MG 32.7±4.8 mm Hg and aortic valve calcium volume 588 (364, 815) mm3. Valve haemodynamics improved following TAVR (AVA 2.5±0.7 cm2, peak velocity 1.9±0.5 m/s and MG 8.4±4.8 mm Hg; p<0.001 for all) and SAVR (AVA 2.0±0.6 cm2, peak velocity 2.1±0.4 m/s and MG 10.0±3.4 mm Hg; p<0.001 for all). At 24 months, the rates of death or disabling stroke were similar (TAVR 7.7% vs SAVR 6.5%; p=0.82). Kansas City Cardiomyopathy Questionnaire overall summary score assessing quality of life improved from baseline to 30 days after TAVR (67.0±20.6 to 89.3±13.4; p<0.001) and SAVR (67.5±19.6 to 78.3±22.3; p=0.001). Conclusions In symptomatic patients with moderately-severe AS, AVR appears to be beneficial. Determination of the clinical and haemodynamic profile of patients who can benefit from earlier isolated AVR needs further investigation in randomised clinical trials.
Perioperative care differences of surgical aortic valve replacement between North America and Europe
Objective To describe differences between North America and Europe in the perioperative management of patients undergoing surgical aortic valve replacement (SAVR). Methods Patients with moderate or greater aortic stenosis or regurgitation requiring SAVR were enrolled in a prospective observational cohort evaluating the safety and efficacy of a new stented bioprosthesis at 25 centres in North America (Canada and the USA) and 13 centres in Europe (Germany, the Netherlands, France, the UK, Switzerland and Italy). While all patients underwent implantation with the same bioprosthetic model, perioperative management was left to the discretion of participating centres. Perioperative care was described in detail including outcomes up to 1-year follow-up. Results Among 1118 patients, 643 (58%) were implanted in North America, and 475 (42%) were implanted in Europe. Patients in Europe were older, had a lower body mass index, less bicuspid disease and worse degree of aortic stenosis at baseline. In Europe, anticoagulant therapy at discharge was more aggressive, whereas length of stay was longer, and discharges directly to home were less common. Rehospitalisation risk was lower in Europe at 30 days (8.5% vs 15.9%) but converged at 1-year follow-up (26.5% vs 28.1%). Within continents, there were major differences between individual countries concerning perioperative management. Conclusion Contemporary perioperative management of SAVR patients varies between North America and Europe in patient selection, procedural techniques, antithrombotic regimen and discharge management. Furthermore, rehospitalisation differed largely between continents and countries. Hence, geographical setting must be considered during design and interpretation of trials on SAVR. Trial registration number NCT02088554.
Structural Valve Deterioration After Self-Expanding Transcatheter or Surgical Aortic Valve Implantation in Patients at Intermediate or High Risk
ImportanceThe frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood.ObjectiveTo evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery.Design, Setting, and ParticipantsThis post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022.InterventionsPatients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies.Main Outcomes and MeasuresThe primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more.ResultsOf 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P &lt; .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis.Conclusions and RelevanceThis study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes.Trial RegistrationClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P &lt; .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P &lt; .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P &lt; .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis
Background: Hemodynamic performance of prostheses after transcatheter aortic valve replacement (TAVR) is generally better than after surgical aortic valve replacement (SAVR), especially in patients with a small native annulus size. However, it remains unclear whether differences are consistent for patients with a different propensity for developing prosthesis-patient mismatch (PPM), considering annulus size and body size of patients. Methods and Results: The SURTAVI trial (Surgical Replacement and Transcatheter Aortic Implantation) compared TAVR using a self-expandable valve with SAVR in intermediate-risk patients. Multidetector computed tomography–based aortic annulus size consisted of the perimeter-derived diameter, which was divided by body surface area to produce an indexed annulus size. Patients were categorized into a small (9–12 mm/m 2 ), medium (>12–14 mm/m 2 ), and large (>14–18 mm/m 2 ) group according to indexed annulus size. We compared TAVR and SAVR for PPM, hemodynamics, and clinical, and functional outcomes through 1-year follow-up within the size groups. Patients who underwent TAVR received a larger prosthesis with increasing indexed annulus size ( P <0.001), while there was no difference in prosthesis size in patients who underwent SAVR ( P =0.74). Patients in all size groups had significantly larger indexed effective orifice area and lower mean gradients at discharge after TAVR versus SAVR. Rates of PPM were significantly lower with TAVR versus SAVR in all groups ( P <0.001) and declined with larger indexed annulus sizes with both TAVR ( P =0.04) and SAVR ( P =0.03). Indexed annulus size was an independent predictor of PPM after TAVR and SAVR. Clinical outcomes were comparable between TAVR and SAVR across all groups, apart from a significantly higher rate of reintervention after TAVR versus SAVR in the large indexed annulus size group (2.5% versus 0%; P =0.01) but without significant interaction ( P int =0.81). Conclusions: Rates of PPM were significantly lower after TAVR than after SAVR across all groups of indexed annulus size, reflecting better hemodynamic performance of transcatheter versus surgical valves, irrespective of the propensity to develop PPM. More attention should be directed to prevention of PPM after SAVR. This information should be considered by the Heart Team to recommend a specific procedure or valve. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01586910.
Frailty and Clinical Outcomes in Chronic Obstructive Pulmonary Disease
Abstract Rationale Frailty represents an increased vulnerability to adverse health outcomes. The frailty phenotype conceptual model (three or more patient attributes of wasting, exhaustion, low activity, slowness, and weakness) is associated with increased morbidity and mortality in geriatric populations. Objectives Our objective was to describe the risks associated with frailty in patients with chronic obstructive pulmonary disease. Methods Data from the National Emphysema Treatment Trial (NETT) were retrospectively analyzed. The frailty phenotype conceptual model was operationalized as three or more frailty parameters (a body mass index decrease of ≥5% over 12 months, self-reported exhaustion, low 6-minute walk distance, or physical activity or respiratory muscle strength in the lowest quartile). Frail participants were compared with participants with two or fewer frailty parameters. Participants were followed starting 12 months after NETT randomization (to minimize surgical effect) for 24 months. Univariate, multivariate, Kaplan-Meier, and Cox proportional hazard analyses were performed, adjusting for treatment arm, age, modified Medical Research Council dyspnea scale, sex, and baseline forced expiratory volume in 1 second (FEV1). Multiple imputation was used for missing values. Results The participants (N = 902) were predominantly white (94.5%) males (59.5%), with a median age of 67 years (interquartile range, 63–70 yr) and a median FEV1% predicted of 26 (interquartile range, 20–33). Six percent of the participants (95% confidence interval [CI], 4.5 to 7.6) were frail. The incidence rate of frailty was 6.4 per 100 person-years. Frail participants reported significantly worse disease-specific and overall quality of life by St. George’s Respiratory Questionnaire total score (mean difference of 11.6; 95% CI, 7.6 to 15.6; P < 0.001), mental composite on Medical Outcomes Survey Short Form-36 (mean difference −6.8; 95% CI, −10.0 to −3.6; P < 0.001), and physical composite scores on Medical Outcomes Survey Short Form-36 (mean difference −16.7; 95% CI, −21.3 to −12.1; P = 0.001). Frail participants had an increased rate of hospitalization (adjusted hazard ratio, 1.6; 95% CI, 1.1 to 2.5; P = 0.02) and an adjusted increase in hospital use of 8.0 days (95% CI, 4.4 to 11.6; P < 0.001) compared with nonfrail participants. Frail participants had a higher mortality rate (adjusted hazard ratio, 1.4; 95% CI, 0.97 to 2.0; P = 0.07). Conclusions Among adults with chronic obstructive pulmonary disease, our measure of frailty (modified from the Fried frailty phenotype) was associated with incident and longer-duration hospitalization, and with poor quality of life.
Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves
Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.