Back to Authors

Mueller, Christian

0000-0002-1120-6405

Mayo Clinic

University of Basel

Citations 11

Undetected Heart Failure in Cardiology: Prevalence, Characteristics, and Outcome
Chollet, Laurève , Rumora, Klara, Durak, Koray , Strebel, Ivo , Huré, Gabrielle , Wussler, Desirée , Belkin, Maria , López‐Ayala, Pedro , Gualandro, Danielle M, Kaplan, Emel, Good, Manuel, Leibundgut, Gregor , Frey, Simon, Zellweger, Michael J. , Müller, Christian , Haaf, Philip , Kühne, Michael , Sticherling, Christian , Mahfoud, Felix , Pfister, Otmar , Zellweger, Michael J , Mueller, Christian , Gualandro, Danielle Menosi , Kaplan, Emel , Frey, Simon , Haaf, Philip

European Journal of Preventive Cardiology | August 17, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/eurjpc/zwag420 Get It

Abstract Aim To confirm or refute recent pilot studies showing unexpectedly high rates of undetected heart failure (HF) in cardiology patients. Methods We assessed the prevalence, characteristics, and outcome of undetected HF in a large prospective cohort study of patients referred for non-invasive coronary artery disease (CAD) work-up with cardiac positron emission tomography computed tomography. HF presence and phenotype were centrally adjudicated by an independent cardiologist according to clinical practice guidelines requiring three mandatory criteria: symptoms, elevated natriuretic peptides, and structural/functional cardiac abnormalities. The endpoint was a composite of cardiovascular death and acute HF (AHF) hospitalization through 2-year of follow-up. Results Among 1738 eligible patients (median age 67 years, 30% women), 138 patients (7.9%) had known HF, and 534 of 1600 patients (33.4%) without known HF had adjudicated undetected HF, resulting in a ratio of undetected HF to known HF of 3.9 (95%CI, 3.2–4.7)-to-1 and a number needed to screen to detect one patient with undetected HF of 3.0 (95%CI, 2.9-3.1). In undetected HF, left ventricular ejection fraction (LVEF) was preserved in 72.3%, mildly reduced in 16%, and reduced in 11.7%. Older age, known CAD, atrial fibrillation, previous pacemaker implantation, and ECG abnormalities were associated with a higher likelihood for undetected HF. Undetected HF was associated with an increased cumulative incidence of the composite endpoint (adjusted subdistribution hazard ratio 7.37 [95%CI, 3.87-14.06], p<0.001, versus no HF). Conclusion One-out-of three patients referred for CAD work-up had undetected HF, which was associated with cardiovascular death and AHF hospitalization.
Digital biomarkers in cardiovascular medicine: a scientific statement of the ESC Working Group on e-Cardiology, the ESC Working Group on Cardiovascular Pharmacotherapy, the European Heart Rhythm Association (EHRA) of the ESC, the Association for Acute Card
Corredoira, Pablo Manuel Fernández, Kaski, Juan Carlos, Duncker, David , Tubaro, Marco , Schuuring, Mark J. , Mamas, Mamas, Petersen, Steffen E, Kemps, Hareld M C, Locati, Emanuela T, Hill, Loreena, Keser, Nurgül , Verstrael, Axel , Friedman, P A, Casado-Arroyo, Rubén , Corredoira, Pablo M , Dörr, Marcus , Wilhelm, Matthias , Schuuring, Mark J , Mueller, Christian , Dilaveris, Polychronis E , Casado-Arroyo, Rubén , Duncker, David , Kaski, Juan Carlos , Wilhelm, Matthias , Petersen, Steffen E. , Vidal-Pérez, Rafael , Jensen, Magnus Thorsten , LUCIA, RAFFAELE DE , Hill, Loreena , Ramírez, Julia , Cluitmans, Matthijs J M , Friedman, Paul A.

European Heart Journal - Digital Health | July 14, 2026 | Volume: 7 | Issue: 6 | Pages: No page available

10.1093/ehjdh/ztag074 Get It

Abstract Cardiovascular disease is the leading cause of morbidity and mortality globally, imposing a substantial patient burden. Digital biomarkers derived from digital health technologies enable quantifiable, near-continuous, real-world capture of pathophysiological signals and are increasingly used across cardiovascular medicine. Their growth is often supported by big data analytics, artificial intelligence and connected sensors within the Internet of Things. This scientific statement systematically reviews digital biomarkers, their clinical utility across the cardiovascular care continuum, and summarizes major methodological and implementation challenges. We searched PubMed/MEDLINE, Embase and Scopus for phase III–IV cardiovascular trials published between 1 January 2019 and 1 August 2024 that collected digital biomarkers. We identified 541 records and included 32 trials (40 reports) enrolling 32 246 participants (44.71% women; mean age 66.2 ± 11.0 years). Heart failure was the most frequent target condition (16 trials, 50%), followed by cardiac implantable electronic devices trials (12 trials, 38%). Digital biomarkers included cardiac rhythm and heart rate, blood pressure, body weight, impedance-based measures, haemodynamic pressures, and physical activity and sleep patterns captured using diverse sensor technologies. Methodological quality was good (modal quality score 5; range 3–7), although most trials were unblinded. Current studies suggest potential clinical utility in selected cardiovascular conditions. Implementation remains challenging because of measurement variability, privacy and regulatory requirements, affordability and reimbursement barriers and inequities in access. Robust validation and outcome- and cost-effectiveness evidence are still needed. Registration number: CRD42024573879.
Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomized trial
Than, Martin , Pickering, John W. , Buchan, Vanessa A, Florkowski, Christopher M , Mills, Nicholas L. , Hamill, Laura , Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika L., Kavsak, Peter, Jaffe, Allan S. , Apple, Fred S. , Cullen, L, Aldous, Sally, Frampton, Christopher MA, Body, Richard, Lord, Sarah Jane, George, Peter Myles, Devlin, Gerard, Kavsak, Peter A. , Mills, Nicholas L , Than, Martin , Pickering, John W , Joyce, Laura R, Buchan, Vanessa, Florkowski, Christopher M , Hamill, Laura, Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika, Kavsak, Peter , Jaffe, Allan S. , Apple, Fred S. , Peacock, William Frank , Cullen, Louise , Aldous, Sally, Richards, Arthur M , Lacey, Cameron, Troughton, Richard W , Frampton, Christopher, Body, Rick , Mueller, Christian , Lord, Sarah, George, Peter M, Devlin, Gerard

No container title available | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.21.26351433 Get It

ABSTRACT BACKGROUND Point-of-care (POC) high-sensitivity cardiac troponin (hs-cTn) testing has the potential to expedite decision-making and reduce emergency department (ED) length of stay for patients presenting with possible myocardial infarction (MI) by ensuring that results are consistently available when looked for by clinicians. We assessed the real-life effectiveness and safety of implementing POC hs-cTn testing in the ED. METHODS We conducted a pragmatic, stepped-wedge cluster randomized trial. The control arm was usual care with an accelerated diagnostic pathway utilizing a single-sample rule-out step with a central laboratory hs-cTn assay. The intervention arm used the same pathway with a POC hs-cTnI. The primary effectiveness outcome was ED length of stay assessed using a generalized linear mixed model, and the safety outcome was 30-day MI or cardiac death. RESULTS Six sites participated with 59,980 ED presentations (44,747 individuals, 61±19 years, 49.5% female) from February 2023 to January 2025, in which 31,392 presentations were during the intervention arm. After adjustment for co-variates associated with length of stay, the intervention reduced length of stay by 13% (95% confidence intervals [CI], 9 to 16%. P<0.001), corresponding to a reduction of 47 minutes (95%CI, 33 to 61 minutes) from a mean length of stay in the control arm of 376 minutes. The 30-day MI or cardiac death rate was similar in the control and intervention arms (0.39% and 0.39% respectively, P=0.54). CONCLUSIONS Implementation of whole-blood hs-cTnI testing at the POC into an accelerated diagnostic pathway was safe and reduced length of stay in the ED compared with laboratory testing. (Australia New Zealand Clinical Trials Registry ACTRN12619001189112) Clinical Perspective What is new? Point-of-care troponin assays with good precision have become available and received regulatory approval as high-sensitivity assays. A pragmatic stepped-wedge cluster randomized trial implementing the validated Siemens VTLi high-sensitivity point-of-care assay into 6 emergency departments investigating ∼60,000 patients, was conducted to ascertain if the rapid turnaround time reduced lengths of stay. Introduction of the VTLi high-sensitivity point-of-care assay into clinical pathways reduced emergency department lengths of stay by an average 13% (47 minutes) without compromising safety. What are the clinical implications? Early decision-making using a point-of-care high-sensitivity troponin assay within a structured clinical pathway was safe. Faster turnaround means troponin results are consistently available when clinicians first seek them. This can facilitate earlier decisions and reduce patient length of stay.
Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 Assay
Knoll, Marko, Daniels, Lori B. , Mueller, Christian, Mills, Nicholas L, Giannitsis, Evangelos, Rösser, Alisa F A, Kurtoic, Dunja, Wahl, Annika , BODY, R. A. F., Christenson, R H, Cobbaert, Christa, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A. S., McCarthy, C. F., McCord, James, Neumann, Johannes T, Omland, Torbjørn, Papendick, Cynthia , Sandoval, Yader, Than, Martin P, Twerenbold, Raphael, Peacock, W Frank, Meex, Steven J. R., Giannitsis, Evangelos , Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mills, Nicholas L. , Mueller, Christian , Mills, Nicholas L , Giannitsis, Evangelos , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Daniels, Lori B , Cobbaert, Christa M. , deFilippi, Christopher R. , McCarthy, Cian P, McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Meex, Steven J.R.

The Journal of Applied Laboratory Medicine | March 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag031 Get It

Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Daniels, Lori B. , Mueller, Christian, Giannitsis, Evangelos, Meex, Steven J. R., Buehlmann, David, Dilba, Peter, Bendig, Garnet, Cole, Mette, Body, Richard, Christenson, Robert H, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A S, McCarthy, Cian P. , McCord, J., Neumann, Johannes T, Omland, T., Papendick, Cynthia , Sandoval, Yader, Twerenbold, Raphael, Peacock, W Frank, Mills, Nicholas L, investigators, the TSIX, Jacobs, Michael B., Lucksinger, Gregg, Powell, Richard, Johnson, Daniel, Coleman, Hugh, Fein, M, Surber, Joseph, Vu, Jack B., Hassman, Michael, Hernandez, John, Kirstein, Judith, Tomaszewski, Christian, Runyon, Michael S. , Gong, Jonathan , Wein, D., Andrabi, Sara , Kopin, David , Larrain, Germain, Tahirkheli, Naheem, Clemency, Brian, Abdullah, Shuaib, Hira, Ravi S. , Klausner, H A, Mahler, Simon A. , Crystal, Chad, Headden, Gary, Chaille, Peter, Cannon, Chad Aaron, Limkakeng, Alexander, Tolia, Vaishal , Knapp, Barry J., Massoomi, Mohammad, Sandoval, Yader, Ko, Emily, Luzzi, Verónica, Christenson, Robert, Carson, Jennifer Powers , Cacioppo, F , Kolev, E., Petrov, Andrey, Hazarbasanov, Dobri , Simova, lana, Magimaiseelan, Luci Suganthi, Kosch, Christine, Klein, G, Mehltretter, Kai, Sauter, Joachim, Baumann, Sybille, Moeckel, Martin, Twerenbold, Raphael, Muller-Hennessen, Matthias, Biener, Moritz , Findeisen, P., Omland, Torbjøm, Wilczek-Kosowska, Urszula, Zimmer-Satora, Ewa, Krecipro-Nizińska, Ewa, Miró, O, Díaz, Víctor Jiménez , Mueller, C, Christ, Michael, Lynch, Stephen, BODY, R. A. F., Matsuki, Shunji, Eto, Takashi, Tanaka, Takanori, Hanada, Ryuzo, Nakagami, Takuo, Nakama, T, Kadota, K., Jing, Shan, Yu, Shuwen, Zhang, Hongxuan, Zhang, Jun, Huo, Yong, Zhang, Yan, Yan, Li, Jiang, Longyuan, Chen, Weiqiang, Huang, Jianying, Zhao, Yan, Guan, Ling, Yang, Yanhua, Zhang, Qin, Qiu, Zhaohui, Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mueller, Christian , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Mills, Nicholas L , Daniels, Lori B , Giannitsis, Evangelos , Meex, Steven J.R. , Christenson, Robert H. , Cobbaert, Christa M. , deFilippi, Christopher R. , McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Surber, Joseph, Tomaszewski, Christian, Clemency, Brian, Headden, Gary , Cannon, Chad, Knapp, Barry , Tran, Nam K , Niederdöckl, Jan Daniel , Kolev, Emil, Popov, Todor, Sauter, Joachim, Baumann, Sybille , Möeckel, Martin , Müller‐Hennessen, Matthias, Findeisen, Peter, Scharnhorst, Volkher , Omland, T, Krecipro-Nizińska, Ewa, Christ, Michael , Nakagami, Takuo, Huo, Yong

Clinical Chemistry | January 18, 2026 | Volume: 72 | Issue: 4 | Pages: 488-502

10.1093/clinchem/hvag011 Get It

Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
Peri-procedural myocardial infarction/injury after percutaneous coronary intervention
Jaffe, Allan S. , Mills, Nicholas L. , Mueller, Christian, Müller, Christian , Mueller, Christian , Mills, Nicholas L , Jaffe, Allan S.

European Heart Journal: Acute Cardiovascular Care | November 20, 2023 | Volume: 12 | Issue: 12 | Pages: 878-880

10.1093/ehjacc/zuad141 Get It

High-sensitivity Troponin I Predicts Major Cardiovascular Events after Non-Cardiac Surgery: A Vascular Events in Non-Cardiac Surgery Patients Cohort Evaluation (VISION) Substudy
Borges, Flávia K. , Duceppe, Emmanuelle , Heels‐Ansdell, Diane , Tandon, Vikas , Pearse, Rupert M. , Srinathan, Sadeesh, Garg, Amit X. , Sapsford, Robert J., Marcucci, Maura , Kavsak, Peter A. , Pettit, Shirley , McGillion, Michael , Conen, David , Thomas, Sabu , Mueller, Christian, Jaffe, Allan S. , Whitlock, Richard , Mueller, Christian , Jaffe, Allan S. , Borges, Flavia , Patel, Ameen , Sessler, Daniel I. , Chan, Matthew T.V. , Ofori, Sandra , Spence, Jessica , Belley‐Côté, Emilie P. , Whitlock, Richard , Lamy, Andre L. , Devereaux, P.J.

Clinical Chemistry | February 10, 2023 | Volume: 69 | Issue: 5 | Pages: 492-499

10.1093/clinchem/hvad005 Get It

Abstract Background Myocardial injury after non-cardiac surgery (MINS), based on measurement of troponin T, is associated with perioperative major adverse cardiovascular events (MACE). We therefore determined the high-sensitivity troponin I (hsTnI) thresholds associated with 30 day MACE after non-cardiac surgery. Methods We performed a nested biobank cohort study of 4553 patients from the Vascular Events in Non-Cardiac Surgery Patients Cohort Evaluation (VISION) Study. We measured hsTnI (ADVIA Centaur® hsTnI assay) on postoperative days 1 to 3 in patients ≥45 years undergoing non-cardiac surgery. An iterative Cox proportional hazard model determined peak postoperative hsTnI thresholds independently associated with MACE (i.e., death, myocardial infarction occurring on postoperative day 4 or after, non-fatal cardiac arrest, or congestive heart failure) within 30 days after surgery. Results MACE occurred in 89/4545 (2.0%) patients. Peak hsTnI values of &lt;75 ng/L, 75 ng/L to &lt;1000 ng/L, and ≥1000 ng/L were associated with 1.2% (95% CI, 0.9–1.6), 7.1% (95% CI, 4.8–10.5), and 25.9% (95% CI, 16.3–38.4) MACE, respectively. Compared to peak hsTnI &lt;75 ng/L, values 75 ng/L to &lt;1000 ng/L and ≥1000 ng/L were associated with adjusted hazard ratios (aHR) of 4.53 (95% CI, 2.75–7.48) and 16.17 (95% CI, 8.70–30.07), respectively. MACE was observed in 9% of patients with peak hsTnI ≥75 ng/L vs 1% in patients with peak hsTnI &lt;75 ng/L (aHR 5.76; 95% CI, 3.64–9.11). A peak hsTnI ≥75 ng/L was associated with MACE in the presence (aHR 9.35; 95% CI, 5.28–16.55) or absence (aHR 3.99; 95% CI, 2.19–7.25) of ischemic features of myocardial injury. Conclusion A peak postoperative hsTnI ≥75 ng/L was associated with &gt;5-fold increase in the risk of 30 days MACE compared to levels &lt;75 ng/L. This threshold could be used for MINS diagnosis when the ADVIA Centaur hsTnI assay is used. Clinicaltrials.gov Registration Number: NCT00512109.
Cardiovascular biomarkers in patients with COVID-19
Mueller, Christian, Jaffe, Allan S. , Huber, Kurt , Mair, Johannes , Cullen, Louise , Hammarsten, Ola , Mills, Nicholas L. , Möckel, Martin , Thygesen, Kristian , Müller, Christian , Mueller, Christian , Huber, Kurt , Mair, Johannes , Cullen, Louise , Mills, Nicholas L , Krychtiuk, Konstantin A , Thygesen, Kristian , Lindahl, Bertil , Mockel, Martin , Giannitsis, Evangelos , Jaffe, Allan S. , Lindahl, Bertil

European Heart Journal. Acute Cardiovascular Care | February 12, 2021 | Volume: 10 | Issue: 3 | Pages: 310-319

10.1093/ehjacc/zuab009 Get It

Abstract The coronavirus disease 2019 (COVID-19) pandemic has increased awareness that severe acute respiratory distress syndrome coronavirus-2 (SARS-CoV-2) may have profound effects on the cardiovascular system. COVID-19 often affects patients with pre-existing cardiac disease, and may trigger acute respiratory distress syndrome (ARDS), venous thromboembolism (VTE), acute myocardial infarction (AMI), and acute heart failure (AHF). However, as COVID-19 is primarily a respiratory infectious disease, there remain substantial uncertainty and controversy whether and how cardiovascular biomarkers should be used in patients with suspected COVID-19. To help clinicians understand the possible value as well as the most appropriate interpretation of cardiovascular biomarkers in COVID-19, it is important to highlight that recent findings regarding the prognostic role of cardiovascular biomarkers in patients hospitalized with COVID-19 are similar to those obtained in studies for pneumonia and ARDS in general. Cardiovascular biomarkers reflecting pathophysiological processes involved in COVID-19/pneumonia and its complications have a role evaluating disease severity, cardiac involvement, and risk of death in COVID-19 as well as in pneumonias caused by other pathogens. First, cardiomyocyte injury, as quantified by cardiac troponin concentrations, and haemodynamic cardiac stress, as quantified by natriuretic peptide concentrations, may occur in COVID-19 as in other pneumonias. The level of those biomarkers correlates with disease severity and mortality. Interpretation of cardiac troponin and natriuretic peptide concentrations as quantitative variables may aid in risk stratification in COVID-19/pneumonia and also will ensure that these biomarkers maintain high diagnostic accuracy for AMI and AHF. Second, activated coagulation as quantified by D-dimers seems more prominent in COVID-19 as in other pneumonias. Due to the central role of endothelitis and VTE in COVID-19, serial measurements of D-dimers may help physicians in the selection of patients for VTE imaging and the intensification of the level of anticoagulation from prophylactic to slightly higher or even therapeutic doses.
ESC Study Group on Cardiac Biomarkers of the Association for Acute CardioVascular Care: A fond farewell at the retirement of CKMB
Jaffe, Allan S. , Lindahl, Bertil , Mueller, Christian, Cullen, Louise , Hammarsten, Ola , Möckel, Martin , Mair, Johannes , Huber, Kurt , Mills, Nicholas L. , Thygesen, Kristian , Müller, Christian , Mueller, Christian , Cullen, Louise , Mockel, Martin , Mair, Johannes , Krychtiuk, Konstantin A , Huber, Kurt , Mills, Nicholas L , Thygesen, Kristian , Lindahl, Bertil , Jaffe, Allan S. , Giannitsis, Evangelos

European Heart Journal | January 14, 2021 | Volume: 42 | Issue: 23 | Pages: 2260-2264

10.1093/eurheartj/ehaa1079 Get It