Abstract Background Point-of-care testing (POCT) has expanded rapidly across healthcare systems, increasing both program scale and operational complexity. However, quantitative benchmarking data describing how POCT programs are structured and supported across institutions remain limited. Methods We conducted a cross-sectional survey to characterize POCT program support, including program scope, staffing, operational practices, governance, and challenges. The survey was distributed electronically through professional networks, and 93 institutional responses were analyzed. Descriptive analyses were performed, and derived metrics, including sites per point-of-care testing coordinator (POCC), were used to evaluate the relationship between program scale and staffing. Results POCT programs demonstrated substantial variability in scale, with wide ranges in the number of testing sites and operator populations. Adoption spanned multiple test categories, and many institutions reported use of multiple platforms for the same assays. Training, competency assessment, and quality management activities were primarily supported by laboratory staff and POCCs, with documentation frequently partially electronic. Median POCC staffing increased with program size; however, sites per POCC also increased significantly across program scale tiers (Kruskal–Wallis P < 0.001). Governance structures and operational responsibilities varied across institutions, and common challenges included staffing limitations, training and compliance burden, multisite coordination, and IT/connectivity constraints. Conclusions POCT programs are expanding in scale and complexity, but workforce capacity and governance structures have not scaled proportionally. This mismatch creates a cumulative and multiplicative operational burden. These findings provide benchmarking data to inform scalable staffing models, governance strategies, and infrastructure development for sustainable POCT program management.
Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
Multicenter Evaluation of a New Strip-Based Blood Glucose System for Point-of-Care Testing in Critical and Non-Critical Care Settings
Background: Evaluation of the performance of Cobas ® Pulse (Roche Diagnostics GmbH, Mannheim, Germany), a new blood glucose (BG) monitoring system (BGMS; referred to here as BGMSA) intended for point-of-care testing using samples from patients in diverse clinical settings by intended point-of-care test operators. Methods: Arterial, capillary, venous, or heel stick whole blood (WB) samples from patients in non-critical and critical care settings were collected and analyzed using BGMSA and the Nova StatStrip ® BGMS (Nova Biomedical, Waltham, MA; referred to here as BGMSB), and a hexokinase comparator (Cobas 6000 Analyzer Series; Roche Diagnostics GmbH). The blood glucose measurement accuracy was assessed by the Food and Drug Administration guidance criteria. Results: Two studies are presented. In the first, 2678 samples (622 arterial, 706 capillary, 1203 venous, 147 heel stick) were collected from 1577 patients in 14 US and three European sites. All accuracy criteria were met for arterial and venous samples considering all data combined. BGMSA showed better accuracy than BGMSB for arterial, venous, and heel stick, and similar results to BGMSB for capillary WB vs venous comparator. No endogenous interference from pO 2 , hematocrit, and sodium was identified. BGMSA was also accurate when analyzing contrived samples used to show accuracy over a wide range of glucose concentrations, alone and when combined with extreme hematocrit. In the second study, 117 capillary fingerstick samples collected at one US site were measured on both BGMSA and the comparator, and all accuracy criteria were met. No clinically significant medical risks were observed via Diabetes Technology Society Error Grids. Conclusions: BGMSA was effective for determining blood glucose in venous, arterial, neonatal arterial, neonatal heel stick, and capillary WB samples.
511 Point-of-care 3-dimensional Body Mapping for Determining Total Body Surface Area in Severely Burned Patients
Abstract Introduction With severe burn injury, there is systemic fluid loss due to inflammatory responses in damaged tissue, leading to disruption of cellular processes. Patient fluid levels are restored with the calculation of total body surface area (TBSA). Clinically used TBSA equations are often outdated and inaccurate with error up to 20%, resulting in misinformed treatment and subsequent sequelae including prolonged hospital length of stay and increased mortality. Our objective, therefore, was to create a point-of-care (POC) system employing 3D imaging technology to accurately calculate TBSA for all patient population varieties. Methods Our team employed an iPad attachable, infrared scanner to create 3D models of the human body. From these models, TBSA can be extrapolated using scan processing software. Subject scans were collected on our device and on a gold standard scanner for comparison of TBSA output. Clinical testing on burn patients is occurring at present to establish scanning precision of TBSA in the burn care environment. Results Non-clinical verification tests of the 3D scanned TBSA revealed a 4.05% error when compared to the gold standard, and precision error of 3.8%. Additionally, we introduced the device into the burn unit for preliminary testing with a physician user and non-patient subjects. The subjects were scanned in a prone position to mimic burn care workflow. Clinician scanning error was 1.41% when compared to the gold standard scan of the same subject. Clinical precision study results are on-going in collection. Conclusions Our device introduces an improved method of TBSA estimation to assist clinicians in making accurate burn care decisions and further precision medicine with greater anthropomteric data, notably for children. This device is one of the first POC-3D scanning technologies to be used in a burn setting and may also be employed at outlying medical facilities. Destructive wildfires and combat burn injuries highlight the need for such a device to standardize the triage of burn victims with and away from experienced medical staff. Applicability of Research to Practice 3D body mapping points to an enhanced method of TBSA calculation and minimally disruptive to the burn workflow. Future developments of 3D scanning include deep learning algorithms to identify and better assess burned surface area. Additionally, further automation of TBSA scan processing to reduce user error in calculation and improve burn injury outcomes.
Point-of-care 3D body-mapping for determining total body surface area of severely burned patients
2019 IEEE Healthcare Innovations and Point of Care Technologies, (HI-POCT) | January 21, 2020 | Volume: No volume available | Issue: No issue available | Pages: 111-114