Back to Authors

McCarthy, Cian P.

https://orcid.org/0000-0003-4944-0034

Mayo Clinic

Mass General Brigham

Citations 4

Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Daniels, Lori B. , Mueller, Christian, Giannitsis, Evangelos, Meex, Steven J. R., Buehlmann, David, Dilba, Peter, Bendig, Garnet, Cole, Mette, Body, Richard, Christenson, Robert H, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A S, McCarthy, Cian P. , McCord, J., Neumann, Johannes T, Omland, T., Papendick, Cynthia , Sandoval, Yader, Twerenbold, Raphael, Peacock, W Frank, Mills, Nicholas L, investigators, the TSIX, Jacobs, Michael B., Lucksinger, Gregg, Powell, Richard, Johnson, Daniel, Coleman, Hugh, Fein, M, Surber, Joseph, Vu, Jack B., Hassman, Michael, Hernandez, John, Kirstein, Judith, Tomaszewski, Christian, Runyon, Michael S. , Gong, Jonathan , Wein, D., Andrabi, Sara , Kopin, David , Larrain, Germain, Tahirkheli, Naheem, Clemency, Brian, Abdullah, Shuaib, Hira, Ravi S. , Klausner, H A, Mahler, Simon A. , Crystal, Chad, Headden, Gary, Chaille, Peter, Cannon, Chad Aaron, Limkakeng, Alexander, Tolia, Vaishal , Knapp, Barry J., Massoomi, Mohammad, Sandoval, Yader, Ko, Emily, Luzzi, Verónica, Christenson, Robert, Carson, Jennifer Powers , Cacioppo, F , Kolev, E., Petrov, Andrey, Hazarbasanov, Dobri , Simova, lana, Magimaiseelan, Luci Suganthi, Kosch, Christine, Klein, G, Mehltretter, Kai, Sauter, Joachim, Baumann, Sybille, Moeckel, Martin, Twerenbold, Raphael, Muller-Hennessen, Matthias, Biener, Moritz , Findeisen, P., Omland, Torbjøm, Wilczek-Kosowska, Urszula, Zimmer-Satora, Ewa, Krecipro-Nizińska, Ewa, Miró, O, Díaz, Víctor Jiménez , Mueller, C, Christ, Michael, Lynch, Stephen, BODY, R. A. F., Matsuki, Shunji, Eto, Takashi, Tanaka, Takanori, Hanada, Ryuzo, Nakagami, Takuo, Nakama, T, Kadota, K., Jing, Shan, Yu, Shuwen, Zhang, Hongxuan, Zhang, Jun, Huo, Yong, Zhang, Yan, Yan, Li, Jiang, Longyuan, Chen, Weiqiang, Huang, Jianying, Zhao, Yan, Guan, Ling, Yang, Yanhua, Zhang, Qin, Qiu, Zhaohui, Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mueller, Christian , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Mills, Nicholas L , Daniels, Lori B , Giannitsis, Evangelos , Meex, Steven J.R. , Christenson, Robert H. , Cobbaert, Christa M. , deFilippi, Christopher R. , McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Surber, Joseph, Tomaszewski, Christian, Clemency, Brian, Headden, Gary , Cannon, Chad, Knapp, Barry , Tran, Nam K , Niederdöckl, Jan Daniel , Kolev, Emil, Popov, Todor, Sauter, Joachim, Baumann, Sybille , Möeckel, Martin , Müller‐Hennessen, Matthias, Findeisen, Peter, Scharnhorst, Volkher , Omland, T, Krecipro-Nizińska, Ewa, Christ, Michael , Nakagami, Takuo, Huo, Yong

Clinical Chemistry | January 18, 2026 | Volume: 72 | Issue: 4 | Pages: 488-502

10.1093/clinchem/hvag011 Get It

Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
High-Sensitivity Cardiac Troponin Assays: From Implementation to Resource Utilization and Cost Effectiveness
Lee, Hong Kee , McCarthy, Cian P. , Jaffe, Allan S. , Body, Richard , Alotaibi, Ahmed , Sandoval, Yader , Januzzi, James L. , Januzzi, James Louis , Body, Rick , Lee, Hong-Kee, Jaffe, Allan S.

The Journal of Applied Laboratory Medicine | January 26, 2025 | Volume: 10 | Issue: 3 | Pages: 710-730

10.1093/jalm/jfae161 Get It

Abstract Background Cardiac troponin is the gold-standard biomarker for the evaluation of patients with suspected acute myocardial infarction (MI). Improvements in assay technology have led to high-sensitivity cardiac troponin assays that, when incorporated into accelerated diagnostic pathways, may rapidly diagnose or exclude acute MI more efficiently than conventional troponin assays. Content In this narrative review, we provide practical suggestions for implementing high-sensitivity cardiac troponin assays, review accelerated diagnostic pathways incorporating these assays, and review the impact of these assays on resource utilization and cost-effectiveness in relation to the evaluation of individuals with possible acute MI. Summary An increasing number of hospitals are transitioning to high-sensitivity cardiac troponin assays. This narrative review provides an overview of the potential benefits of this transition.
Abstract 11108: Implementation of High-Sensitivity Cardiac Troponin Assays in the United States: A Report From the NCDR Chest Pain - MI Registry
McCarthy, Cian P. , Li, Shuang , Wang, Tracy Y , Raber, Inbar , Sandoval, Yader , Smilowitz, Nathaniel R. , Kontos, Michael C. , Apple, Fred S. , Daniels, Lori B. , Newby, L. Kristin , Jaffe, Allan S. , Daniels, Lori B , Wasfy, Jason H. , Pandey, Ambarish , Lemos, James A. de , Jaffe, Allan S. , Januzzi, James Louis

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.11108 Get It

Introduction: High-sensitivity cardiac troponin (hs-cTn) assays were first approved for use in the U.S. in 2017. They are the guideline preferred biomarker to evaluate patients with acute chest pain. Few data exist regarding implementation of hs-cTn assays in the U.S. Hypothesis: We hypothesize that use of hs-cTn assays has increased over time and that patients assessed with hs-cTn have a shorter length of stay (LOS) and similar use of cardiac testing. Methods: We examined trends in implementation of hs-cTn assays among participating hospitals in the NCDR Chest Pain MI Registry from 1/1/2019 through 9/30/2021. Excluding STEMI patients, associations between hs-cTn use, in-hospital diagnostic imaging, and patient outcomes were assessed using logistic or negative binomial regression models. Results: Among 550 participating hospitals with 251,000 patients in the registry, implementation of hs-cTn assays increased from 3.3% in Q1, 2019 to 32.6% in Q3, 2021 (P trend <0.0001; Figure ). Implementation was similar by hospital size, type, and geographic location. hs-cTn use was associated with more echocardiography among patients with NSTE-ACS (82% vs. 75%; aOR: 1.43, 95% CI, 1.19-1.73) but not in low-risk chest pain. hs-cTn use was associated with decreased odds of invasive coronary angiography in low-risk patients (3.7% vs. 4.5%; aOR: 0.73, 95% CI, 0.58-0.92) but similar use in NSTE-ACS. There was no association between hs-cTn use and non-invasive stress/CTCA testing. Among NSTE-ACS patients, hs-cTn use was not associated with PCI, CABG, or in-hospital mortality. Use of hs-cTn was associated with shorter LOS (47.6 hours vs. 48 hours; IRR: 0.96, 95% CI, 0.93-0.98). Conclusions: Although implementation of hs-cTn among U.S. hospitals is increasing, most U.S hospitals continue to use less-sensitive troponin assays. hs-cTn use was associated with shorter LOS overall, greater use of echocardiography in NSTE-ACS, and lower use of invasive angiograms in low-risk patients.
Myocardial Injury in the Era of High-Sensitivity Cardiac Troponin Assays
McCarthy, Cian P. , Raber, Inbar , Chapman, Andrew R. , Sandoval, Yader , Apple, Fred S. , Mills, Nicholas L. , Mills, Nicholas L , Januzzi, James Louis

JAMA Cardiology | August 7, 2019 | Volume: 4 | Issue: 10 | Pages: 1034

10.1001/jamacardio.2019.2724 Get It