Back to Authors

Mills, Nicholas L.

https://orcid.org/0000-0003-0533-7991

Mayo Clinic

University of Edinburgh

Citations 18

Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomized trial
Than, Martin , Pickering, John W. , Buchan, Vanessa A, Florkowski, Christopher M , Mills, Nicholas L. , Hamill, Laura , Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika L., Kavsak, Peter, Jaffe, Allan S. , Apple, Fred S. , Cullen, L, Aldous, Sally, Frampton, Christopher MA, Body, Richard, Lord, Sarah Jane, George, Peter Myles, Devlin, Gerard, Kavsak, Peter A. , Mills, Nicholas L , Than, Martin , Pickering, John W , Joyce, Laura R, Buchan, Vanessa, Florkowski, Christopher M , Hamill, Laura, Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika, Kavsak, Peter , Jaffe, Allan S. , Apple, Fred S. , Peacock, William Frank , Cullen, Louise , Aldous, Sally, Richards, Arthur M , Lacey, Cameron, Troughton, Richard W , Frampton, Christopher, Body, Rick , Mueller, Christian , Lord, Sarah, George, Peter M, Devlin, Gerard

No container title available | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.21.26351433 Get It

ABSTRACT BACKGROUND Point-of-care (POC) high-sensitivity cardiac troponin (hs-cTn) testing has the potential to expedite decision-making and reduce emergency department (ED) length of stay for patients presenting with possible myocardial infarction (MI) by ensuring that results are consistently available when looked for by clinicians. We assessed the real-life effectiveness and safety of implementing POC hs-cTn testing in the ED. METHODS We conducted a pragmatic, stepped-wedge cluster randomized trial. The control arm was usual care with an accelerated diagnostic pathway utilizing a single-sample rule-out step with a central laboratory hs-cTn assay. The intervention arm used the same pathway with a POC hs-cTnI. The primary effectiveness outcome was ED length of stay assessed using a generalized linear mixed model, and the safety outcome was 30-day MI or cardiac death. RESULTS Six sites participated with 59,980 ED presentations (44,747 individuals, 61±19 years, 49.5% female) from February 2023 to January 2025, in which 31,392 presentations were during the intervention arm. After adjustment for co-variates associated with length of stay, the intervention reduced length of stay by 13% (95% confidence intervals [CI], 9 to 16%. P<0.001), corresponding to a reduction of 47 minutes (95%CI, 33 to 61 minutes) from a mean length of stay in the control arm of 376 minutes. The 30-day MI or cardiac death rate was similar in the control and intervention arms (0.39% and 0.39% respectively, P=0.54). CONCLUSIONS Implementation of whole-blood hs-cTnI testing at the POC into an accelerated diagnostic pathway was safe and reduced length of stay in the ED compared with laboratory testing. (Australia New Zealand Clinical Trials Registry ACTRN12619001189112) Clinical Perspective What is new? Point-of-care troponin assays with good precision have become available and received regulatory approval as high-sensitivity assays. A pragmatic stepped-wedge cluster randomized trial implementing the validated Siemens VTLi high-sensitivity point-of-care assay into 6 emergency departments investigating ∼60,000 patients, was conducted to ascertain if the rapid turnaround time reduced lengths of stay. Introduction of the VTLi high-sensitivity point-of-care assay into clinical pathways reduced emergency department lengths of stay by an average 13% (47 minutes) without compromising safety. What are the clinical implications? Early decision-making using a point-of-care high-sensitivity troponin assay within a structured clinical pathway was safe. Faster turnaround means troponin results are consistently available when clinicians first seek them. This can facilitate earlier decisions and reduce patient length of stay.
Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 Assay
Knoll, Marko, Daniels, Lori B. , Mueller, Christian, Mills, Nicholas L, Giannitsis, Evangelos, Rösser, Alisa F A, Kurtoic, Dunja, Wahl, Annika , BODY, R. A. F., Christenson, R H, Cobbaert, Christa, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A. S., McCarthy, C. F., McCord, James, Neumann, Johannes T, Omland, Torbjørn, Papendick, Cynthia , Sandoval, Yader, Than, Martin P, Twerenbold, Raphael, Peacock, W Frank, Meex, Steven J. R., Giannitsis, Evangelos , Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mills, Nicholas L. , Mueller, Christian , Mills, Nicholas L , Giannitsis, Evangelos , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Daniels, Lori B , Cobbaert, Christa M. , deFilippi, Christopher R. , McCarthy, Cian P, McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Meex, Steven J.R.

The Journal of Applied Laboratory Medicine | March 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag031 Get It

Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Analytical Error of Cardiac Troponin and Impact on the Performance of Accelerated Diagnostic Protocols in Patients with Acute Chest Pain
Saeed, Nasir , Restan, Ingar Ziad , Steiro, Ole‐Thomas , Tjora, Hilde L , Langørgen, Jørund , Skadberg, Øyvind , Mjelva, Øistein R, Bonarjee, Vernon , Bjørneklett, Rune , Steinsvik, Trude , Vikenes, Kjell , Omland, Torbjørn , Apple, Fred S. , Jaffe, Allan S. , Mills, Nicholas L. , Kavsak, Peter A. , Collinson, Paul O , Aakre, Kristin M , Mills, Nicholas L , Saeed, Nasir , Jaffe, Allan S. , Collinson, Paul , Aakre, Kristin M.

Clinical Chemistry | September 10, 2025 | Volume: 71 | Issue: 12 | Pages: 1243-1256

10.1093/clinchem/hvaf116 Get It

Abstract Background This study simulates how assay-specific bias influences the diagnostic performance of 0/1-h accelerated diagnostic protocols (ADPs) for 3 different high-sensitivity cardiac troponin (hs-cTn) assays. Methods We included 1493 patients presenting with chest pain. hs-cTnT (Roche Diagnostics), hs-cTnI from Abbott Diagnostics (hs-cTnI-A), and Siemens Healthineers (hs-cTnI-S) were measured at admission. The absolute total error observed in a state-of-the-art EQA study were added to the admission concentrations, producing 6 new variables being adjusted for maximum possible bias (if analytical variation is 0) (+biasmean, +biasmax95%CI, +biasmin95%CI, −biasmean, −biasmax95%CI, −biasmin95%CI). The influence of this “worst-case scenario” bias was compared after calculating sensitivity, specificity, negative and positive predictive values, and rule-out proportion for 30-day myocardial infarction or death for the observed and bias-adjusted hs-cTn concentrations. Results For 0-h rule-out, hs-cTnI-S and hs-cTnT had a sensitivity of &gt;99.0%, compared to 97.7% for hs-cTnI-A. After adding the bias, sensitivity was unchanged for hs-cTnI-S (99.5%), but lower for hs-cTnT (95.5%), and hs-cTnI-A (96.2%). For the 0-/1-h algorithm, adding bias reduced sensitivity to 95.5% for hs-cTnT, while both hs-cTnI algorithms were unchanged (100.0%). Rule-out proportions for 0 h ranged from 0% to 60.0% for hs-cTnT, 28.2%–62.7% for hs-cTnI-A, and 3.5%–35.5% for hs-cTnI-S. For the 0-/1-h algorithm, ranges were 57.7%–75.8% (hs-cTnT), 52.8%–67.5% (hs-cTnI-A), and 45.7%–61.2% (hs-cTnI-S), Conclusion Analytical bias of hs-cTn assays affects the clinical rule-out rate of the 0/1-h ADPs more than the diagnostic sensitivity. Bias may have a greater influence on the proportion of patients requiring hospital admission and may contribute to the heterogeneity of the reported rule-out rates of current ADPs. ClinicalTrials.gov Registration Number: NCT02620202
The assessment and management of patients with type 2 myocardial infarction: an international Delphi study
Taggart, Caelan , Ferry, Amy V. , Chapman, Andrew , Schulberg, Stacey D. , Bularga, Anda , Wereski, Ryan, Boeddinghaus, Jasper, Kimenai, Dorien M , Lowry, Matthew T.H. , Daniels, Lori B. , French, J. , Gaggin, Hanna K. , Huynh, T. , Jacquin, Laurent , Jaffe, A S, Jernberg, Tomas , Koronowski, Ran, McCarthy, Cian P. , McCord, James , Mickley, Hans , Mueller, Christian , Newby, L. Kristin , Parsonage, William , Smith, Stephen W., Sandoval, Yader, Smilowitz, Nathaniel R. , Thygesen, Kristian , Mills, Nicholas L. , Boeddinghaus, Jasper , Cullen, Louise , Jernberg, Tomas , Mamas, Mamas , Mueller, Christian , Raphael, Claire , White, Harvey Douglas , Lindahl, Bertil , Thygesen, Kristian , Mills, Nicholas L , Daniels, Lori B , Boeddinghaus, Jasper , Chew, Derek P. , Cullen, Louise , Devereaux, P.J. , Mamas, Mamas A. , Morrow, David A. , Raphael, Claire E. , Smer, Aiman Miloud , Sandoval, Yader , Eggers, Kai M. , Lindahl, Bertil

European Heart Journal - Quality of Care and Clinical Outcomes | September 2, 2025 | Volume: 11 | Issue: 8 | Pages: 1421-1430

10.1093/ehjqcco/qcaf069 Get It

Abstract Aims Type 2 myocardial infarction due to myocardial oxygen supply–demand imbalance is associated with poor outcomes. There are no guidelines to inform care for these patients. The consensus on the assessment and management of type 2 myocardial infarction is gained. Methods and results An international e-Delphi study including experts in type 2 myocardial infarction identified through systematic review was conducted. Participants were asked to describe their approach to (i) definition and diagnosis, (ii) risk stratification, (iii) assessment of coronary artery disease and cardiac function, (iv) specialty management, (v) treatment and secondary prevention, and (vi) communication and rehabilitation. Statements generated in round one were circulated, with consensus defined a priori as ≥70% agreement on a 5-point Likert scale. Where no consensus was reached, statements were amended and recirculated for a final round. The response rate was 56% (38/68), 54% (37/68), and 72% (49/68) in the first, second, and third rounds, respectively. Following the first round, 67 unique statements were generated across six domains. Overall, consensus was achieved on 64% (43/67) of statements. Consensus was achieved for 42% (5/12) of statements on the diagnosis of type 2 myocardial infarction, 75% (3/4) on risk stratification, 50% (9/18) on the assessment of coronary artery disease and cardiac function, 60% (6/10), on specialty management, 100% (9/9) on treatment and secondary prevention, and 79% (11/15) on communication and rehabilitation. Conclusion Consensus was obtained across a number of domains for the assessment and management of patients with type 2 myocardial infarction. However, there was limited agreement amongst experts on the diagnostic criteria, which may benefit from refinement.
Challenges of using natriuretic peptides to screen for the risk of developing heart failure in patients with diabetes: a report from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee on Clinical Applications of Car
Jaffe, Allan S. , Sandoval, Yader, Mills, Nicholas L. , Omland, Torbjørn , Aakre, Kristin M. , Mills, Nicholas L , Aakre, Kristin M , Jaffe, Allan S. , Sandoval, Yader

Clinical Chemistry and Laboratory Medicine (CCLM) | August 11, 2025 | Volume: 63 | Issue: 11 | Pages: 2130-2139

10.1515/cclm-2025-0863 Get It

Abstract Background Several guidelines groups have made recommendations about how to use natriuretic peptides (NPs) to screen patients with diabetes for incipient heart failure. This group is at risk for undetected and stage B heart failure, where structural heart disease is present despite the absence of clinical signs and symptoms. These recommendations are based on trial data that suggest there are therapeutic options to benefit these patients. Content These guidelines do not adequately account for the marked analytic differences between NP assays nor their high degree of biological and analytical variability. Thus, without additional data and guidance, these recommendations could lead to excessive testing for some groups but might disadvantage others. In addition, these issues could lead to difficulties in the interpretation of values. Accordingly, the Committee on Clinical Applications of Cardiac Bio Markers of the International Federation of Clinical Chemistry has developed a consensus educational document to describe these difficulties and define areas where additional data are needed. Clinicians should be cognizant of differences in the assays for NPs, the high degree of variability of values, differences in sex and ethnicity and the need to factor in a variety of clinical and treatment variables in interpreting NP values. Summary These suggestions for diabetes eventually will include others at high risk. They will require close attention to the issues involved in measuring and interpreting NP values.
High-sensitivity point-of-care measurement of cardiac troponin
Cullen, Louise , Mair, Johannes , Hammarsten, Ola , Boeddinghaus, Jasper , Daniels, Lori B. , Huber, Kurt , Giannitsis, Evangelos , Jaffe, Allan S. , Kimenai, Dorien M , Möckel, Martin , Mueller, Christian, Thielmann, Matthias , Thygesen, Kristian , Mills, Nicholas L. , Boeddinghaus, Jasper , Daniels, Lori B , Giannitsis, Evangelos , Kimenai, Dorien M , Lindahl, Bertil , Mockel, Martin , Thielmann, Matthias , Thygesen, Kristian , Mills, Nicholas L , Cullen, Louise , Stengaard, Carsten , Jaffe, Allan S. , Krychtiuk, Konstantin A , Lindahl, Bertil

European Heart Journal | June 4, 2025 | Volume: 47 | Issue: 12 | Pages: 1392-1402

10.1093/eurheartj/ehaf407 Get It

Abstract New technologies enabling access to high-sensitivity cardiac troponin (hs-cTn) assays at the point of care (POC) are available for routine use. POC technology can accelerate cardiac troponin testing within the hospital setting and support testing in other healthcare environments. Pre-analytical and analytical issues unique to POC testing are discussed. The opportunities and the evidence needed to support the routine use of hs-cTn POC assays in clinical care are outlined. Based on recent developments, the potential impact of hs-cTn at the POC in multiple clinical settings is described, and a roadmap of the steps required for successful implementation is provided.
Impact of high-sensitivity cardiac troponin I assay imprecision on the safety of a single-sample rule-out approach for myocardial infarction
Li, Ziwen , Tew, Yong Yong , Kavsak, Peter A. , Aakre, Kristin M. , Jaffe, Allan S. , Apple, Fred S. , Collinson, Paul , Mills, Nicholas L. , Chapman, Andrew R. , Collinson, Paul O , Mills, Nicholas L , Aakre, Kristin M , Jaffe, Allan S.

Clinical Chemistry and Laboratory Medicine (CCLM) | September 19, 2024 | Volume: 63 | Issue: 3 | Pages: e59-e62

10.1515/cclm-2024-1011 Get It

Peri-procedural myocardial infarction/injury after percutaneous coronary intervention
Jaffe, Allan S. , Mills, Nicholas L. , Mueller, Christian, Müller, Christian , Mueller, Christian , Mills, Nicholas L , Jaffe, Allan S.

European Heart Journal: Acute Cardiovascular Care | November 20, 2023 | Volume: 12 | Issue: 12 | Pages: 878-880

10.1093/ehjacc/zuad141 Get It

Antibody-mediated interferences affecting cardiac troponin assays: recommendations from the IFCC Committee on Clinical Applications of Cardiac Biomarkers
Hammarsten, Ola , Warner, Janet , Lam, Leo , Kavsak, Peter A. , Aakre, Kristin M. , Collinson, Paul , Jaffe, Allan S. , Saenger, Amy K., Mills, Nicholas L. , Omland, Torbjørn , Ordóñez‐Llanos, Jordi , Apple, Fred S. , Aakre, Kristin M , Collinson, Paul O , Mills, Nicholas L , Lindahl, Bertil , Jaffe, Allan S. , Body, Richard

Clinical Chemistry and Laboratory Medicine (CCLM) | March 23, 2023 | Volume: 61 | Issue: 8 | Pages: 1411-1419

10.1515/cclm-2023-0028 Get It

Abstract The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.