Back to Authors

Saenger, Amy K.

Mayo Clinic

Mayo Clinic

Citations 41

Abstract 19365: Serial Changes in ST2 are Superior to Other Biomarkers in the Prediction of Adverse Events in a Cohort of Ambulatory Chronic Heart Failure Patients
Saenger, Amy K., Lueke, Alan J., Grill, Diane E. , Jaffe, Allan S. , Miller, Wayne L. , Jaffe, Allan S.

Circulation | April 23, 2024 | Volume: 126 | Issue: suppl_21 | Pages: No page available

10.1161/circ.126.suppl_21.a19365 Get It

Background: Disease progression in heart failure (HF) reflects multiple neurohormonal derangements resulting in adverse prognosis in the absence of overt clinical events. ST2 is up-regulated in response to cardiac injury/hemodynamic stress while modulating cardiac remodeling via inflammatory and apoptotic pathways. Accordingly, we evaluated changes in ST2 over time in conjunction with troponin T (cTnT) and BNP in ambulatory patients with chronic HF. Methods: A cohort of 191 NYHA class III-IV HF patients was prospectively evaluated with serial specimens collected every 3 months over a 2-year period. Primary end points were death or cardiac transplantation; secondary end points were combined death/transplantation and HF-related hospitalization. Plasma ST2 (Critical Diagnostics) was evaluated against contemporary cTnT (Roche 4th generation) and BNP (Shinogi) assays. Gender specific cut-points (>49.3 and >33.5 ng/mL for males and females, respectively) and a clinically defined optimal cut-point for ST2 (>35 ng/mL) were evaluated. Results: Time-dependent analyses (dichotomous and continuous variable) demonstrated ST2 gender specific cut-points were superior to a single ST2 cut-point and associated with an increased risk of death or transplantation (HR 4.8, 95% CI 2.8 to 8.3, p<0.0001) and combined death/transplantation/HF-hospitalization (HR 2.1, 95% CI 1.7 to 2.5, p<0.0001). Although cTnT remained the strongest predictor of death/transplantation (HR 3.2, 95% CI 1.6 to 5.4, p<0.0001) in multivariate analyses adjusted for cTnT and BNP, ST2 (HR 3.0, 95% CI 1.6 to 5.4, p=0.0003) added significantly to predictive accuracy. Furthermore, elevated ST2 was the only independent predictor of HF-hospitalization (HR 1.7, 95% CI 1.4 to 2.1, p<0.0001). In these models BNP was no longer significantly predictive (HR 1.2, 95% CI 0.7 to 2.2, p=0.58). Conclusions: Serial monitoring of changes in ST2 using gender specific cut-points adds to the diagnostic ability of cTnT in predicting mortality and/or transplantation in outpatients with chronic HF. ST2 uniquely predicts HF-hospitalization/death/transplantation, suggesting a serial monitoring strategy with cTnT and ST2 will optimize identification of HF patients at increased risk for events.
Antibody-mediated interferences affecting cardiac troponin assays: recommendations from the IFCC Committee on Clinical Applications of Cardiac Biomarkers
Hammarsten, Ola , Warner, Janet , Lam, Leo , Kavsak, Peter A. , Aakre, Kristin M. , Collinson, Paul , Jaffe, Allan S. , Saenger, Amy K., Mills, Nicholas L. , Omland, Torbjørn , Ordóñez‐Llanos, Jordi , Apple, Fred S. , Aakre, Kristin M , Collinson, Paul O , Mills, Nicholas L , Lindahl, Bertil , Jaffe, Allan S. , Body, Richard

Clinical Chemistry and Laboratory Medicine (CCLM) | March 23, 2023 | Volume: 61 | Issue: 8 | Pages: 1411-1419

10.1515/cclm-2023-0028 Get It

Abstract The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.
Cardiac troponin measurement at the point of care: educational recommendations on analytical and clinical aspects by the IFCC Committee on Clinical Applications of Cardiac Bio-Markers (IFCC C-CB)
Aakre, Kristin M. , Saenger, Amy K., Body, Rick, Hammarsten, Ole, Jaffe, Allan S. , Kavsak, Peter A. , Omland, Torbjørn , Ordonez-Lianos, Jordi, Karon, Brad S. , Apple, Fred S. , Aakre, Kristin M , Karon, Brad, Collinson, Paul , Body, Rick, Jaffe, Allan S.

Clinical Chemistry and Laboratory Medicine (CCLM) | January 13, 2023 | Volume: 61 | Issue: 6 | Pages: 989-998

10.1515/cclm-2022-1270 Get It

Abstract The International Federation of Clinical Chemistry and Laboarator Medicine (IFCC) Committee on Clinical Applications of Cardiac Bio-Markers (C-CB) has provided evidence-based educational resources to aid and improve the understanding of important analytical and clinical aspects of cardiac biomarkers. The present IFCC C-CB educational report focuses on recommendations for appropriate use, analytical performance, and gaps in clinical studies related to the use of cardiac troponin (cTn) by point of care (POC) measurement, often referred to as a point of care testing (POCT). The use of high-sensitivity (hs)-cTn POC devices in accelerated diagnostic protocols used in emergency departments or outpatient clinics investigating acute coronary syndrome has the potential for improved efficacy, reduction of length of stay and reduced costs in the health care system. POCT workflow integration includes location of the instrument, assignment of collection and testing responsibility to (non-lab) staff, instrument maintenance, in-service and recurrent training, quality control, proficiency assessments, discrepant result trapping, and troubleshooting and inventory management.
Analytical Considerations in Deriving 99th Percentile Upper Reference Limits for High-Sensitivity Cardiac Troponin Assays: Educational Recommendations from the IFCC Committee on Clinical Application of Cardiac Bio-Markers
Aakre, Kristin M. , Saenger, Amy K., Body, Richard , Collinson, Paul , Hammarsten, Ola , Jaffe, Allan S. , Kavsak, Peter A. , Omland, Torbjørn , Ordonez-Lianos, Jordi, Apple, Fred S. , Body, Rick , Collinson, Paul O , Aakre, Kristin M , Jaffe, Allan S.

Clinical Chemistry | June 18, 2022 | Volume: 68 | Issue: 8 | Pages: 1022-1030

10.1093/clinchem/hvac092 Get It

Abstract The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers provides evidence-based educational documents to facilitate uniform interpretation and utilization of cardiac biomarkers in clinical laboratories and practice. The committee’s goals are to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay in clinical practice. Measurement of high-sensitivity cardiac troponin (hs-cTn) assays is a cornerstone in the clinical evaluation of patients with symptoms and/or signs of acute cardiac ischemia. To define myocardial infarction, the Universal Definition of Myocardial Infarction requires patients who manifest with features suggestive of acute myocardial ischemia to have at least one cTn concentration above the sex-specific 99th percentile upper reference limit (URL) for hs-cTn assays and a dynamic pattern of cTn concentrations to fulfill the diagnostic criteria for MI. This special report provides an overview of how hs-cTn 99th percentile URLs should be established, including recommendations about prescreening and the number of individuals required in the reference cohort, how statistical analysis should be conducted, optimal preanalytical and analytical protocols, and analytical/biological interferences or confounds that can affect accurate determination of the 99th percentile URLs. This document also provides guidance and solutions to many of the issues posed.
Short- and Long-Term Biological Variability of Small Dense LDL, HDL3, and Triglyceride-Rich Lipoprotein Cholesterol
Fatica, Erica M. , Jenkins, Sarah M. , Scott, Renee, Block, Darci R , Meeusen, Jeffrey W. , Baumann, N, Saenger, Amy K., Scott, Renee’ J, Baumann, Nikola A, Donato, Leslie J.

The Journal of Applied Laboratory Medicine | May 11, 2022 | Volume: 7 | Issue: 5 | Pages: 1047-1061

10.1093/jalm/jfac039 Get It

Abstract Background Measurement of cholesterol within lipoprotein subfractions may aid in cardiovascular disease prediction. Simple, homogenous enzymatic assays for the direct measurement of lipoprotein subfractions have been developed to measure small dense low-density lipoprotein cholesterol (sdLDL-C), high-density lipoprotein-3 cholesterol (HDL3-C), and triglyceride-rich lipoprotein (TRL-C) cholesterol. The objective of this study was to determine biological variability for sdLDL-C, HDL3-C, and TRL-C in a healthy reference population to facilitate interpretation of these analytes. Methods Serum samples were collected from 24 healthy subjects (n = 14 female/10 male) daily for 3 days while non-fasting, and daily for 5 days, weekly for 4 weeks, and monthly for 6 months after overnight fasting. sdLDL-C, HDL3-C, and TRL-C cholesterol were measured by homogenous enzymatic assays. Sources of variability (between-subject, within-subject, and analytical) were calculated using random-effects regression models. Reference change value (RCV) and index of individuality (II) for each time period were determined from the variance components. Results Analytic variability (daily, weekly, and monthly CVA) was &lt;3% for each analyte. Monthly within-subject variability (CVI) was 17.1% for sdLDL-C, 7.4% for HDL3-C, and 25.7% for TRL-C. Most of the monthly variation was attributed to between-subject variation for all 3 analytes. Overall RCVs for monthly measurements were 18.1 mg/dL for sdLDL-C, 6.1 mg/dL for HDL3-C, and 16.0 mg/dL for TRL-C. IIs were &lt;0.6 for sdLDL-C and HDL3-C, and 0.81 for TRL-C. Conclusions sdLDL-C, HDL3-C, and TRL-C showed moderate within-subject variability, but high between-subject variability, in a healthy reference population. Given the high individuality of each analyte, population-based reference intervals may be inadequate to detect clinically significant changes.
The Need to Develop Clinical Guidance for the Use of High-Sensitivity Cardiac Troponin in Pediatric and Neonatal Patients
Wang, Alan , Sandoval, Yader , Apple, Fred S. , Homme, James L. , Jaffe, Allan S. , Apple, Fred S., Saenger, Amy K., Kavsak, Peter A. , Omland, Torbjørn , Hammarsten, Ola , Homme, James, Jaffe, Allan S. , Ordóñez‐Llanos, Jordi , Collinson, Paul , Body, Richard , Aakre, Kristin M.

Clinical Chemistry | April 21, 2022 | Volume: 68 | Issue: 7 | Pages: 884-886

10.1093/clinchem/hvac072 Get It

The Biological Variability of Plasma Ceramides in Healthy Subjects
Ramos, Paola , Jenkins, Sarah M. , Hartman, Stacy, Saenger, Amy K., Baumann, N, Block, Darci R , Jaffe, Allan S. , Meeusen, Jeffrey W. , Donato, Leslie J. , Hartman, Stacy J, Baumann, Nikola A, Block, Darci R , Jaffe, Allan S.

The Journal of Applied Laboratory Medicine | January 6, 2022 | Volume: 7 | Issue: 4 | Pages: 863-870

10.1093/jalm/jfac002 Get It

AbstractBackgroundCeramides are bioactive lipid species that mediate numerous cell-signaling events. Elevated plasma ceramides concentration constitutes a risk factor for several pathologies. Multiple studies have affirmed the plasma concentrations of 4 specific ceramides (Cer16:0, Cer18:0, Cer24:0, and Cer24:1) can predict cardiovascular disease risk. Furthermore, these ceramides can be altered by many lipid-lowering therapies. Understanding the biological variability within an individual, and within a population, will further inform the clinical use of plasma ceramides as a biomarker. In this study, we aimed to define the intra- and interbiological variability of ceramides in a healthy reference population in a weekly and monthly manner.MethodsFasting plasma from 24 healthy adults was collected daily (5 days), weekly (4 weeks), and monthly (7 months). Ceramide concentrations were measured with liquid chromatography–mass spectrometry (LC–MS). For analysis, we used random-effects regression models to estimate variance components.ResultsThe analytical variability was smaller compared to the biological variability overall. The greatest variation reported was between-subject variation for all ceramide species. The critical difference-reference change value (RCV) for within-subject variations monthly were 0.07 mcmol/L (Cer16:0), 0.04 mcmol/L (Cer18:0), 1.09 mcmol/L (Cer24:0), and 0.27 mcmol/L (Cer24:1). The index of individuality (IOI) of ceramides were 0.82 (Cer16:0), 0.96 (Cer18:0), 1.06 (Cer24:0), and 0.89 (Cer24:1). The most consistent ceramide species was Cer18:0 with the lowest within- and between-subject critical differences in weekly and monthly measurements.ConclusionsOverall, this study demonstrates that the variability of ceramide concentrations at different time points is minimal within individuals, allowing a single draw to be sufficient at least in a yearly time frame.
Biological Variability of Small Dense LDL, HDL3, and Triglyceride-Rich Lipoprotein Cholesterol
Fatica, Erica M. , Jenkins, Sarah Howard, Scott, Renee, Block, Darci R , Meeusen, Jeffrey W. , Baumann, N, Saenger, Amy K., Donato, Leslie J.

American Journal of Clinical Pathology | October 31, 2021 | Volume: 156 | Issue: Supplement_1 | Pages: S4-S4

10.1093/ajcp/aqab189.006 Get It

Abstract The guideline-recommended lipid panel for cardiovascular disease (CVD) risk assessment measures total cholesterol, high-density lipoprotein (HDL) cholesterol, triglycerides, and calculated low-density lipoprotein (LDL) cholesterol. Measured cholesterol in subfractions of HDL and LDL purportedly improve CVD risk prediction. Homogenous enzymatic methods are now available for measurement of the cholesterol within small dense LDL (sLDL), small dense HDL (HDL3), and triglyceride-rich lipoproteins (TRL). For meaningful interpretation of these measurements, an understanding of the potential sources and extent of result variability is needed. The smallest difference between serial measurements within a patient that likely reflects a change in clinical status is called the reference change value (RCV). Biological variability and reference change values (RCV) are well-characterized for basic lipids but there is limited information for sLDL, HDL3 or TRL. The objective of this study was to determine intra- and inter-individual variability for sLDL, HDL3, and TRL in a healthy reference population. Serum samples were collected from 24 healthy subjects (n=14 female/10 male) daily for three days (non-fasting), daily for five days (fasting), weekly for four weeks (fasting), and monthly for 7 months (fasting). sLDL, HDL3, and TRL cholesterol were measured in duplicate by enzymatic colorimetric assays (Denka, Japan) on a Roche Cobas c501. Each source of variability (between subject, within subject, and analytical) was calculated using random-effects regression models to estimate each variance component including the overall variation, standard deviation (SD), coefficient of variation (CV), and proportion of total variance (between-subject, within-subject, and analytical). Using these analytical and biological variances, the reference change value (RCV), index of individuality (IoI), and intraclass correlation coefficient (ICC) were determined. Analytic variability (CVa) from monthly testing was 1.2%, 1.1%, and 1.5% for sLDL, HDL3, and TRL, respectively. Monthly within-subject variability (CVw) was 17.1% for sLDL, 7.4% for HDL3 and 25.7% for TRL. Monthly between-subject variability (CVb) was 32.2%, 13.93%, and 33.4% for sLDL, HDL3, and TRL, respectively. Most of the monthly variation was attributed to between-subject variation for all three tests. Within-subject variation accounted for 37% of TRL variation and 22% for both sLDL and HLD3. Within-subject RCVs for monthly measurements were 16.9mg/dL for sLDL, 5.3mg/dL for HDL3, and 15.1mg/dL for TRL. IoIs for monthly testing were 0.81 for TRL, 0.57 for sLDL, and 0.61 for HDL3. Our data demonstrate that sLDL, HDL3, and TRL show low analytical variability, moderate within-subject variability, but high between-subject variability when measured by homogenous assays in a healthy population. The IoI value (&gt;0.6) for TRL suggests use of a reference interval is appropriate for result interpretation. Conversely, clinical cut-points may be more useful than reference intervals for sLDL and HDL3 which had IoIs ~0.6. These findings may be useful for clinical interpretation, particularly when comparing successive measurements of these analytes.
Sex-specific cut-off values for soluble suppression of tumorigenicity 2 (ST2) biomarker increase its cardiovascular prognostic value in the community
AbouEzzeddine, Omar F. , Saenger, Amy K., Jaffe, Allan S. , Harmon, David M , McKie, Paul M. , AbouEzzeddine, Omar F , Harmon, David , Scott, Christopher G. , Jaffe, Allan S.

Biomarkers | July 16, 2021 | Volume: 26 | Issue: 7 | Pages: 639-646

10.1080/1354750x.2021.1956590 Get It

Getting Cardiac Troponin Right: Appraisal of the 2020 European Society of Cardiology Guidelines for the Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation by the International Federation of Clinical Chemis
Apple, Fred S. , Kavsak, Peter A. , Body, Richard , Saenger, Amy K., Omland, Torbjørn , Hammarsten, Ola , Jaffe, Allan S. , Body, Rick , Collinson, Paul , Ordóñez‐Llanos, Jordi , Jaffe, Allan S.

Clinical Chemistry | December 29, 2020 | Volume: 67 | Issue: 5 | Pages: 730-735

10.1093/clinchem/hvaa337 Get It