Back to Authors

Kavsak, Peter A.

https://orcid.org/0000-0003-4576-4744

Mayo Clinic

McMaster University

Citations 31

Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomized trial
Than, Martin , Pickering, John W. , Buchan, Vanessa A, Florkowski, Christopher M , Mills, Nicholas L. , Hamill, Laura , Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika L., Kavsak, Peter, Jaffe, Allan S. , Apple, Fred S. , Cullen, L, Aldous, Sally, Frampton, Christopher MA, Body, Richard, Lord, Sarah Jane, George, Peter Myles, Devlin, Gerard, Kavsak, Peter A. , Mills, Nicholas L , Than, Martin , Pickering, John W , Joyce, Laura R, Buchan, Vanessa, Florkowski, Christopher M , Hamill, Laura, Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika, Kavsak, Peter , Jaffe, Allan S. , Apple, Fred S. , Peacock, William Frank , Cullen, Louise , Aldous, Sally, Richards, Arthur M , Lacey, Cameron, Troughton, Richard W , Frampton, Christopher, Body, Rick , Mueller, Christian , Lord, Sarah, George, Peter M, Devlin, Gerard

No container title available | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.21.26351433 Get It

ABSTRACT BACKGROUND Point-of-care (POC) high-sensitivity cardiac troponin (hs-cTn) testing has the potential to expedite decision-making and reduce emergency department (ED) length of stay for patients presenting with possible myocardial infarction (MI) by ensuring that results are consistently available when looked for by clinicians. We assessed the real-life effectiveness and safety of implementing POC hs-cTn testing in the ED. METHODS We conducted a pragmatic, stepped-wedge cluster randomized trial. The control arm was usual care with an accelerated diagnostic pathway utilizing a single-sample rule-out step with a central laboratory hs-cTn assay. The intervention arm used the same pathway with a POC hs-cTnI. The primary effectiveness outcome was ED length of stay assessed using a generalized linear mixed model, and the safety outcome was 30-day MI or cardiac death. RESULTS Six sites participated with 59,980 ED presentations (44,747 individuals, 61±19 years, 49.5% female) from February 2023 to January 2025, in which 31,392 presentations were during the intervention arm. After adjustment for co-variates associated with length of stay, the intervention reduced length of stay by 13% (95% confidence intervals [CI], 9 to 16%. P<0.001), corresponding to a reduction of 47 minutes (95%CI, 33 to 61 minutes) from a mean length of stay in the control arm of 376 minutes. The 30-day MI or cardiac death rate was similar in the control and intervention arms (0.39% and 0.39% respectively, P=0.54). CONCLUSIONS Implementation of whole-blood hs-cTnI testing at the POC into an accelerated diagnostic pathway was safe and reduced length of stay in the ED compared with laboratory testing. (Australia New Zealand Clinical Trials Registry ACTRN12619001189112) Clinical Perspective What is new? Point-of-care troponin assays with good precision have become available and received regulatory approval as high-sensitivity assays. A pragmatic stepped-wedge cluster randomized trial implementing the validated Siemens VTLi high-sensitivity point-of-care assay into 6 emergency departments investigating ∼60,000 patients, was conducted to ascertain if the rapid turnaround time reduced lengths of stay. Introduction of the VTLi high-sensitivity point-of-care assay into clinical pathways reduced emergency department lengths of stay by an average 13% (47 minutes) without compromising safety. What are the clinical implications? Early decision-making using a point-of-care high-sensitivity troponin assay within a structured clinical pathway was safe. Faster turnaround means troponin results are consistently available when clinicians first seek them. This can facilitate earlier decisions and reduce patient length of stay.
Analytical Error of Cardiac Troponin and Impact on the Performance of Accelerated Diagnostic Protocols in Patients with Acute Chest Pain
Saeed, Nasir , Restan, Ingar Ziad , Steiro, Ole‐Thomas , Tjora, Hilde L , Langørgen, Jørund , Skadberg, Øyvind , Mjelva, Øistein R, Bonarjee, Vernon , Bjørneklett, Rune , Steinsvik, Trude , Vikenes, Kjell , Omland, Torbjørn , Apple, Fred S. , Jaffe, Allan S. , Mills, Nicholas L. , Kavsak, Peter A. , Collinson, Paul O , Aakre, Kristin M , Mills, Nicholas L , Saeed, Nasir , Jaffe, Allan S. , Collinson, Paul , Aakre, Kristin M.

Clinical Chemistry | September 10, 2025 | Volume: 71 | Issue: 12 | Pages: 1243-1256

10.1093/clinchem/hvaf116 Get It

Abstract Background This study simulates how assay-specific bias influences the diagnostic performance of 0/1-h accelerated diagnostic protocols (ADPs) for 3 different high-sensitivity cardiac troponin (hs-cTn) assays. Methods We included 1493 patients presenting with chest pain. hs-cTnT (Roche Diagnostics), hs-cTnI from Abbott Diagnostics (hs-cTnI-A), and Siemens Healthineers (hs-cTnI-S) were measured at admission. The absolute total error observed in a state-of-the-art EQA study were added to the admission concentrations, producing 6 new variables being adjusted for maximum possible bias (if analytical variation is 0) (+biasmean, +biasmax95%CI, +biasmin95%CI, −biasmean, −biasmax95%CI, −biasmin95%CI). The influence of this “worst-case scenario” bias was compared after calculating sensitivity, specificity, negative and positive predictive values, and rule-out proportion for 30-day myocardial infarction or death for the observed and bias-adjusted hs-cTn concentrations. Results For 0-h rule-out, hs-cTnI-S and hs-cTnT had a sensitivity of &gt;99.0%, compared to 97.7% for hs-cTnI-A. After adding the bias, sensitivity was unchanged for hs-cTnI-S (99.5%), but lower for hs-cTnT (95.5%), and hs-cTnI-A (96.2%). For the 0-/1-h algorithm, adding bias reduced sensitivity to 95.5% for hs-cTnT, while both hs-cTnI algorithms were unchanged (100.0%). Rule-out proportions for 0 h ranged from 0% to 60.0% for hs-cTnT, 28.2%–62.7% for hs-cTnI-A, and 3.5%–35.5% for hs-cTnI-S. For the 0-/1-h algorithm, ranges were 57.7%–75.8% (hs-cTnT), 52.8%–67.5% (hs-cTnI-A), and 45.7%–61.2% (hs-cTnI-S), Conclusion Analytical bias of hs-cTn assays affects the clinical rule-out rate of the 0/1-h ADPs more than the diagnostic sensitivity. Bias may have a greater influence on the proportion of patients requiring hospital admission and may contribute to the heterogeneity of the reported rule-out rates of current ADPs. ClinicalTrials.gov Registration Number: NCT02620202
Assessing Analytical Performance and Correct Classification for Cardiac Troponin Deltas Across Diagnostic Pathways Used for Myocardial Infarction
Kavsak, Peter A. , Sharif, Sameer , Demian, Wael L. L., Belley‐Côté, Emilie P. , Blank, David , Knauer, Michael J. , Thorlacius, Laurel , Raizman, Joshua E., Huang, Yun , Beriault, Daniel R. , Fung, Angela W.S. , Yip, Paul S. F. , Clark, L., Abramson, Beth L. , Friedman, Steven , Atkinson, Paul , Suskin, Neville , Scheuermeyer, Frank , Humphries, Karin H. , Mondoux, Shawn , Ainsworth, Craig , Borges, Flávia K. , Worster, Andrew , McRae, Andrew D. , Jaffe, Allan S. , Belley-Cote, Emilie P , Knauer, Michael , Thorlacius, Laurel , Fung, Angela W S , Yip, Paul M , Friedman, Steven M , Suskin, Neville , Ainsworth, Craig , Borges, Flavia , McRae, Andrew , Jaffe, Allan S. , Beriault, Daniel R , Choi, Won-Shik, Taher, Jennifer , Shea, Jennifer L. , McLaren, Jesse T. T. , Chen‐Tournoux, Annabel , Sivilotti, Marco L.A. , Thiruganasambandamoorthy, Venkatesh , Aakre, Kristin M.

Diagnostics | June 30, 2025 | Volume: 15 | Issue: 13 | Pages: 1652

10.3390/diagnostics15131652 Get It

Background: In the emergency setting, many diagnostic pathways incorporate change in high-sensitivity cardiac troponin (hs-cTn) concentrations (i.e., the delta) to classify patients as low-risk (rule-out) or high-risk (rule-in) for possible myocardial infarction (MI). However, the impact of analytical variation on the delta for correct classification is unknown, especially at concentrations below and around the 99th percentile. Our objective was to assess the impact of delta variation for correct risk classification across the European Society of Cardiology (ESC 0/1 h and 0/2 h), the High-STEACS, and the common change criteria (3C) pathways. Methods: A yearlong accuracy study for hs-cTnT was performed where laboratories across Canada tested three patient-based samples (level 1 target value = 6 ng/L, level 2 target value = 9 ng/L, level 3 target value = 12 ng/L) monthly across 41 different analyzers. The assigned low-delta between levels 1 and 2 was 3 ng/L (i.e., 9 − 6 = 3 ng/L) and the assigned high-delta between levels 1 and 3 was 6 ng/L (i.e., 12 − 6 = 6 ng/L). The low- and high-deltas for each analyzer were determined monthly from the measured values, with the difference calculated from the assigned deltas. The obtained deltas were then assessed via the different pathways on correct classification (i.e., percent correct with 95% confidence intervals, CI) and using non-parametric analyses. Results: The median (interquartile range) difference between the measured versus assigned low-delta (n = 436) and high-delta (n = 439) was −1 ng/L (−1 to 0). The correct classification differed among the pathways. The ESC 0/1 h pathway yielded the lowest percentage of correct classification at 35.3% (95% CI: 30.8 to 40.0) for the low-delta and 90.0% (95% CI: 86.8 to 92.6) for the high-delta. The 3C and ESC 0/2 h pathways yielded higher and equivalent estimates on correct classification: 95.2% (95% CI: 92.7 to 97.0) for the low-delta and 98.2% (95% CI: 96.4 to 99.2) for the high-delta. The High-STEACS pathway yielded 99.5% (95% CI: 98.4 to 99.9) of correct classifications for the high-delta but only 36.2% (95% CI: 31.7 to 40.9) for the low-delta. Conclusions: Analytical variation will impact risk classification for MI when using hs-cTn deltas alone per the pathways. The 3C and ESC 0/2 h pathways have <5% misclassification when using deltas for hs-cTnT in this dataset. Additional studies with different hs-cTnI assays at concentrations below and near the 99th percentile are warranted to confirm these findings.
Impact of high-sensitivity cardiac troponin I assay imprecision on the safety of a single-sample rule-out approach for myocardial infarction
Li, Ziwen , Tew, Yong Yong , Kavsak, Peter A. , Aakre, Kristin M. , Jaffe, Allan S. , Apple, Fred S. , Collinson, Paul , Mills, Nicholas L. , Chapman, Andrew R. , Collinson, Paul O , Mills, Nicholas L , Aakre, Kristin M , Jaffe, Allan S.

Clinical Chemistry and Laboratory Medicine (CCLM) | September 19, 2024 | Volume: 63 | Issue: 3 | Pages: e59-e62

10.1515/cclm-2024-1011 Get It

Protocol for Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomised qua
Pickering, John W. , Devlin, Gerard, Aldous, Sally, Jaffe, Allan S. , Apple, Fred S. , Kavsak, Peter A. , Cullen, Louise , Lord, Sarah J. , Joyce, Laura R , Frampton, Chris , Than, Martin , Lord, Sarah J , Joyce, Laura , Richards, Arthur M , Than, Martin , Cullen, Louise , Body, Richard , Jaffe, Allan S. , Mills, Nicholas L , Troughton, Richard W. , Peacock, William Frank , Lacey, Cameron James , Richards, Mark , Pitama, Suzanne G

BMJ Open | June 13, 2024 | Volume: 14 | Issue: 6 | Pages: e083752

10.1136/bmjopen-2023-083752 Get It

Introduction Clinical assessment in emergency departments (EDs) for possible acute myocardial infarction (AMI) requires at least one cardiac troponin (cTn) blood test. The turn-around time from blood draw to posting results in the clinical portal for central laboratory analysers is ~1–2 hours. New generation, high-sensitivity, point-of-care cardiac troponin I (POC-cTnI) assays use whole blood on a bedside (or near bedside) analyser that provides a rapid (8 min) result. This may expedite clinical decision-making and reduce length of stay. Our purpose is to determine if utilisation of a POC-cTnI testing reduces ED length of stay. We also aim to establish an optimised implementation process for the amended clinical pathway. Methods and analysis This quality improvement initiative has a pragmatic multihospital stepped-wedge cross-sectional cluster randomised design. Consecutive patients presenting to the ED with symptoms suggestive of possible AMI and having a cTn test will be included. Clusters (comprising one or two hospitals each) will change from their usual-care pathway to an amended pathway using POC-cTnI—the ‘intervention’. The dates of change will be randomised. Changes occur at 1 month intervals, with a minimum 2 month ‘run-in’ period. The intervention pathway will use a POC-cTnI measurement as an alternate to the laboratory-based cTn measurement. Clinical decision-making steps and logic will otherwise remain unchanged. The POC-cTnI is the Siemens (Erlangen Germany) Atellica VTLi high-sensitivity cTnI assay. The primary outcome is ED length of stay. The safety outcome is cardiac death or AMI within 30 days for patients discharged directly from the ED. Ethics and dissemination Ethics approval has been granted by the New Zealand Southern Health and Disability Ethics Committee, reference 21/STH/9. Results will be published in a peer-reviewed journal. Lay and academic presentations will be made. Māori-specific results will be disseminated to Māori stakeholders. Trial registration number ACTRN12619001189112.
The Role of Artificial Intelligence for Providing Scientific Content for Laboratory Medicine
Wu, Alan H.B. , Jaffe, Allan S. , Peacock, W. Franklin, Kavsak, Peter A. , Christenson, Robert H. , Greene, Dina , Jaffe, Allan S. , Greene, Dina N.

The Journal of Applied Laboratory Medicine | December 16, 2023 | Volume: 9 | Issue: 2 | Pages: 386-393

10.1093/jalm/jfad095 Get It

Abstract Background Artificial intelligence (AI) promises to become an important tool in the practice of laboratory medicine. AI programs are available online that can provide concise medical and laboratory information within seconds after a question is submitted. Methods We posed the following contemporary and relevant question for clinical chemists using an AI program: “Should labs eliminate CK-MB testing?” The results of this inquiry were critically reviewed by a cardiologist, emergency department physician, and clinical laboratorians for accuracy and appropriateness. Results An AI report answering this question was generated within 15 s. The experts felt that the information was inaccurate with the statements that CK-MB results are released earlier than cardiac troponin (cTn), and are more useful for detection of myocardial injury in patients with renal insufficiencies. The summary omitted discussion on the ongoing debate for periprocedural detection of acute myocardial infarction (MI), the perceived value for detection of reinfarction, the value in risk stratification compared to cTn, the economic justification for testing both CK-MB and cTn, and medicolegal aspects of testing when results are discordant. Conclusions At this time, AI does not appear to be ready to be used by clinical laboratories for answering important practice questions.
Association of Preoperative Growth Differentiation Factor-15 Concentrations and Postoperative Cardiovascular Events after Major Noncardiac Surgery
Duceppe, Emmanuelle , Conen, David , Tiboni, Maria , Kavsak, Peter A. , Srinathan, Sadeesh, Pearse, Rupert M. , Jaffe, Allan S. , Heels‐Ansdell, Diane , Garg, Amit X. , Pettit, Shirley , Sapsford, Robert J., Borges, Flávia K. , Chan, Matthew T.V. , Patel, Ameen , Sessler, Daniel I. , Ofori, Sandra , Jaffe, Allan S. , Devereaux, P.J.

Anesthesiology | April 11, 2023 | Volume: 138 | Issue: 5 | Pages: 508-522

10.1097/aln.0000000000004539 Get It

Background The association between growth differentiation factor-15 concentrations and cardiovascular disease has been well described. The study hypothesis was that growth differentiation factor-15 may help cardiac risk stratification in noncardiac surgical patients, in addition to clinical evaluation. Methods The objective of the study was to determine whether preoperative serum growth differentiation factor-15 is associated with the composite primary outcome of myocardial injury after noncardiac surgery and vascular death at 30 days and can improve cardiac risk prediction in noncardiac surgery. This is a prospective cohort study of patients 45 yr or older having major noncardiac surgery. The association between preoperative growth differentiation factor-15 and the primary outcome was determined after adjusting for the Revised Cardiac Risk Index. Preoperative N-terminal-pro hormone brain natriuretic peptide was also added to compare predictive performance with growth differentiation factor-15. Results Between October 27, 2008, and October 30, 2013, a total of 5,238 patients were included who had preoperative growth differentiation factor-15 measured (median, 1,325; interquartile range, 880 to 2,132 pg/ml). The risk of myocardial injury after noncardiac surgery and vascular death was 99 of 1,705 (5.8%) for growth differentiation factor-15 less than 1,000 pg/ml, 161 of 1,332 (12.1%) for growth differentiation factor-15 1,000 to less than 1,500 pg/ml, 302 of 1476 (20.5%) for growth differentiation factor-15 1,500 to less than 3,000 pg/ml, and 247 of 725 (34.1%) for growth differentiation factor-15 concentrations 3,000 pg/ml or greater. Compared to patients who had growth differentiation factor-15 concentrations less than 1,000 pg/ml, the corresponding adjusted hazard ratio for each growth differentiation factor-15 category was 1.93 (95% CI, 1.50 to 2.48), 3.04 (95% CI, 2.41 to 3.84), and 4.8 (95% CI, 3.76 to 6.14), respectively. The addition of growth differentiation factor-15 improved cardiac risk classification by 30.1% (301 per 1,000 patients) compared to Revised Cardiac Risk Index alone. It also provided additional risk classification beyond the combination of preoperative N-terminal-pro hormone brain natriuretic peptide and Revised Cardiac Risk Index (16.1%; 161 per 1,000 patients). Conclusions Growth differentiation factor-15 is strongly associated with 30-day risk of major cardiovascular events and significantly improved cardiac risk prediction in patients undergoing noncardiac surgery. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
Antibody-mediated interferences affecting cardiac troponin assays: recommendations from the IFCC Committee on Clinical Applications of Cardiac Biomarkers
Hammarsten, Ola , Warner, Janet , Lam, Leo , Kavsak, Peter A. , Aakre, Kristin M. , Collinson, Paul , Jaffe, Allan S. , Saenger, Amy K., Mills, Nicholas L. , Omland, Torbjørn , Ordóñez‐Llanos, Jordi , Apple, Fred S. , Aakre, Kristin M , Collinson, Paul O , Mills, Nicholas L , Lindahl, Bertil , Jaffe, Allan S. , Body, Richard

Clinical Chemistry and Laboratory Medicine (CCLM) | March 23, 2023 | Volume: 61 | Issue: 8 | Pages: 1411-1419

10.1515/cclm-2023-0028 Get It

Abstract The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.
High-sensitivity Troponin I Predicts Major Cardiovascular Events after Non-Cardiac Surgery: A Vascular Events in Non-Cardiac Surgery Patients Cohort Evaluation (VISION) Substudy
Borges, Flávia K. , Duceppe, Emmanuelle , Heels‐Ansdell, Diane , Tandon, Vikas , Pearse, Rupert M. , Srinathan, Sadeesh, Garg, Amit X. , Sapsford, Robert J., Marcucci, Maura , Kavsak, Peter A. , Pettit, Shirley , McGillion, Michael , Conen, David , Thomas, Sabu , Mueller, Christian, Jaffe, Allan S. , Whitlock, Richard , Mueller, Christian , Jaffe, Allan S. , Borges, Flavia , Patel, Ameen , Sessler, Daniel I. , Chan, Matthew T.V. , Ofori, Sandra , Spence, Jessica , Belley‐Côté, Emilie P. , Whitlock, Richard , Lamy, Andre L. , Devereaux, P.J.

Clinical Chemistry | February 10, 2023 | Volume: 69 | Issue: 5 | Pages: 492-499

10.1093/clinchem/hvad005 Get It

Abstract Background Myocardial injury after non-cardiac surgery (MINS), based on measurement of troponin T, is associated with perioperative major adverse cardiovascular events (MACE). We therefore determined the high-sensitivity troponin I (hsTnI) thresholds associated with 30 day MACE after non-cardiac surgery. Methods We performed a nested biobank cohort study of 4553 patients from the Vascular Events in Non-Cardiac Surgery Patients Cohort Evaluation (VISION) Study. We measured hsTnI (ADVIA Centaur® hsTnI assay) on postoperative days 1 to 3 in patients ≥45 years undergoing non-cardiac surgery. An iterative Cox proportional hazard model determined peak postoperative hsTnI thresholds independently associated with MACE (i.e., death, myocardial infarction occurring on postoperative day 4 or after, non-fatal cardiac arrest, or congestive heart failure) within 30 days after surgery. Results MACE occurred in 89/4545 (2.0%) patients. Peak hsTnI values of &lt;75 ng/L, 75 ng/L to &lt;1000 ng/L, and ≥1000 ng/L were associated with 1.2% (95% CI, 0.9–1.6), 7.1% (95% CI, 4.8–10.5), and 25.9% (95% CI, 16.3–38.4) MACE, respectively. Compared to peak hsTnI &lt;75 ng/L, values 75 ng/L to &lt;1000 ng/L and ≥1000 ng/L were associated with adjusted hazard ratios (aHR) of 4.53 (95% CI, 2.75–7.48) and 16.17 (95% CI, 8.70–30.07), respectively. MACE was observed in 9% of patients with peak hsTnI ≥75 ng/L vs 1% in patients with peak hsTnI &lt;75 ng/L (aHR 5.76; 95% CI, 3.64–9.11). A peak hsTnI ≥75 ng/L was associated with MACE in the presence (aHR 9.35; 95% CI, 5.28–16.55) or absence (aHR 3.99; 95% CI, 2.19–7.25) of ischemic features of myocardial injury. Conclusion A peak postoperative hsTnI ≥75 ng/L was associated with &gt;5-fold increase in the risk of 30 days MACE compared to levels &lt;75 ng/L. This threshold could be used for MINS diagnosis when the ADVIA Centaur hsTnI assay is used. Clinicaltrials.gov Registration Number: NCT00512109.
Cardiac troponin measurement at the point of care: educational recommendations on analytical and clinical aspects by the IFCC Committee on Clinical Applications of Cardiac Bio-Markers (IFCC C-CB)
Aakre, Kristin M. , Saenger, Amy K., Body, Rick, Hammarsten, Ole, Jaffe, Allan S. , Kavsak, Peter A. , Omland, Torbjørn , Ordonez-Lianos, Jordi, Karon, Brad S. , Apple, Fred S. , Aakre, Kristin M , Karon, Brad, Collinson, Paul , Body, Rick, Jaffe, Allan S.

Clinical Chemistry and Laboratory Medicine (CCLM) | January 13, 2023 | Volume: 61 | Issue: 6 | Pages: 989-998

10.1515/cclm-2022-1270 Get It

Abstract The International Federation of Clinical Chemistry and Laboarator Medicine (IFCC) Committee on Clinical Applications of Cardiac Bio-Markers (C-CB) has provided evidence-based educational resources to aid and improve the understanding of important analytical and clinical aspects of cardiac biomarkers. The present IFCC C-CB educational report focuses on recommendations for appropriate use, analytical performance, and gaps in clinical studies related to the use of cardiac troponin (cTn) by point of care (POC) measurement, often referred to as a point of care testing (POCT). The use of high-sensitivity (hs)-cTn POC devices in accelerated diagnostic protocols used in emergency departments or outpatient clinics investigating acute coronary syndrome has the potential for improved efficacy, reduction of length of stay and reduced costs in the health care system. POCT workflow integration includes location of the instrument, assignment of collection and testing responsibility to (non-lab) staff, instrument maintenance, in-service and recurrent training, quality control, proficiency assessments, discrepant result trapping, and troubleshooting and inventory management.