Most patients with chest pain do not have acute myocardial infarction (AMI), yet post-AMI rule-out disposition remains variable. Detectable but sub-99th percentile high-sensitivity cardiac troponin I (hs-cTnI) provides additional prognostic information. We evaluated the economic value of hs-cTnI-guided hospitalizations among non-AMI patients. We analyzed 1481 non-AMI chest pain visits with detectable baseline hs-cTnI across 29 U.S. emergency departments (2014–2016) in the prospective HIGH-US trial using the Atellica IM TnIH assay(Siemens Healthcare Diagnostics, Tarrytown, NY, US). We compared observed standard-of-care admissions with modeled pathways incorporating hs-cTnI thresholds and risk scores, assessing admission rates, costs, and diagnostic accuracy for 30-day death/MI. Overall, 1.0% (n = 15/1481) experienced 30-day death/MI. Standard-of-care admitted 59% of patients with 93% sensitivity and 41% specificity. The modeled pathway using hs-cTnI ≥ 5 ng/L plus non-low risk scores was associated with reduced projected admission of 41%, higher specificity of 60%, and the same 93% sensitivity. Estimated per-patient diagnostic costs were lower under Scenario 1 (noninvasive diagnostic testing only; $1025 vs. $1139) and under Scenario 2 (including inpatient/invasive procedures; $2672 vs. $3536). In subgroups, higher hs-cTnI thresholds conferred further economic benefit without compromising sensitivity. Incorporating sub-99th percentile hs-cTnI thresholds alongside risk scores may support more efficient resource use while maintaining safety, although findings require prospective validation.
Multicenter Evaluation of a New Strip-Based Blood Glucose System for Point-of-Care Testing in Critical and Non-Critical Care Settings
Background: Evaluation of the performance of Cobas ® Pulse (Roche Diagnostics GmbH, Mannheim, Germany), a new blood glucose (BG) monitoring system (BGMS; referred to here as BGMSA) intended for point-of-care testing using samples from patients in diverse clinical settings by intended point-of-care test operators. Methods: Arterial, capillary, venous, or heel stick whole blood (WB) samples from patients in non-critical and critical care settings were collected and analyzed using BGMSA and the Nova StatStrip ® BGMS (Nova Biomedical, Waltham, MA; referred to here as BGMSB), and a hexokinase comparator (Cobas 6000 Analyzer Series; Roche Diagnostics GmbH). The blood glucose measurement accuracy was assessed by the Food and Drug Administration guidance criteria. Results: Two studies are presented. In the first, 2678 samples (622 arterial, 706 capillary, 1203 venous, 147 heel stick) were collected from 1577 patients in 14 US and three European sites. All accuracy criteria were met for arterial and venous samples considering all data combined. BGMSA showed better accuracy than BGMSB for arterial, venous, and heel stick, and similar results to BGMSB for capillary WB vs venous comparator. No endogenous interference from pO 2 , hematocrit, and sodium was identified. BGMSA was also accurate when analyzing contrived samples used to show accuracy over a wide range of glucose concentrations, alone and when combined with extreme hematocrit. In the second study, 117 capillary fingerstick samples collected at one US site were measured on both BGMSA and the comparator, and all accuracy criteria were met. No clinically significant medical risks were observed via Diabetes Technology Society Error Grids. Conclusions: BGMSA was effective for determining blood glucose in venous, arterial, neonatal arterial, neonatal heel stick, and capillary WB samples.
Performance of Three Anti-SARS-CoV-2 Anti-S and One Anti-N Immunoassays for the Monitoring of Immune Status and Vaccine Response
This study aimed to evaluate and compare the performance of three anti-S and one anti-N assays that were available to the project in detecting antibody levels after three commonly used SARS-CoV-2 vaccines (Pfizer, Moderna, and Johnson & Johnson). It also aimed to assess the association of age, sex, race, ethnicity, vaccine timing, and vaccine side effects on antibody levels in a cohort of 827 individuals. In September 2021, 698 vaccinated individuals donated blood samples as part of the Association for Diagnostics & Laboratory Medicine (ADLM) COVID-19 Immunity Study. These individuals also participated in a comprehensive survey covering demographic information, vaccination status, and associated side effects. Additionally, 305 age- and gender-matched samples were obtained from the ADLM 2015 sample bank as pre-COVID-19-negative samples. All these samples underwent antibody level analysis using three anti-S assays, namely Beckman Access SARS-CoV-2 IgG (Beckman assay), Ortho Clinical Diagnostics VITROS Anti-SARS-CoV-2 IgG (Ortho assay), Siemens ADVIA Centaur SARS-CoV-2 IgG (Siemens assay), and one anti-N antibody assay: Bio-Rad Platelia SARS-CoV-2 Total Ab assay (BioRad assay). A total of 827 samples (580 COVID-19 samples and 247 pre-COVID-19 samples) received results for all four assays and underwent further analysis. Beckman, Ortho, and Siemens anti-S assays showed an overall sensitivity of 99.5%, 97.6%, and 96.9%, and specificity of 90%, 100%, and 99.6%, respectively. All three assays indicated 100% sensitivity for individuals who received the Moderna vaccine and boosters, and over 99% sensitivity for the Pfizer vaccine. Sensitivities varied from 70.4% (Siemens), 81.5% (Ortho), and 96.3% (Beckman) for individuals who received the Johnson & Johnson vaccine. BioRad anti-N assays demonstrated 46.2% sensitivity and 99.25% specificity based on results from individuals with self-reported infection. The highest median anti-S antibody levels were measured in individuals who received the Moderna vaccine, followed by Pfizer and then Johnson & Johnson vaccines. Higher anti-S antibody levels were significantly associated with younger age and closer proximity to the last vaccine dose but were not associated with gender, race, or ethnicity. Participants with higher anti-S levels experienced significantly more side effects as well as more severe side effects (e.g., muscle pain, chills, fever, and moderate limitations) (p < 0.05). Anti-N antibody levels only indicated a significant correlation with headache. This study indicated performance variations among different anti-S assays, both among themselves and when analyzing individuals with different SARS-CoV-2 vaccines. Caution should be exercised when conducting large-scale studies to ensure that the same platform and/or assays are used for the most effective interpretation of the data.
The Role of Artificial Intelligence for Providing Scientific Content for Laboratory Medicine
Abstract Background Artificial intelligence (AI) promises to become an important tool in the practice of laboratory medicine. AI programs are available online that can provide concise medical and laboratory information within seconds after a question is submitted. Methods We posed the following contemporary and relevant question for clinical chemists using an AI program: “Should labs eliminate CK-MB testing?” The results of this inquiry were critically reviewed by a cardiologist, emergency department physician, and clinical laboratorians for accuracy and appropriateness. Results An AI report answering this question was generated within 15 s. The experts felt that the information was inaccurate with the statements that CK-MB results are released earlier than cardiac troponin (cTn), and are more useful for detection of myocardial injury in patients with renal insufficiencies. The summary omitted discussion on the ongoing debate for periprocedural detection of acute myocardial infarction (MI), the perceived value for detection of reinfarction, the value in risk stratification compared to cTn, the economic justification for testing both CK-MB and cTn, and medicolegal aspects of testing when results are discordant. Conclusions At this time, AI does not appear to be ready to be used by clinical laboratories for answering important practice questions.
Large-Scale Scientific Study Led by a Professional Organization during the COVID-19 Pandemic: Operations, Best Practices, and Lessons Learned
Abstract In 2021, the Association for Diagnostics & Laboratory Medicine (ADLM) (formerly the American Association for Clinical Chemistry [AACC]) developed a scientific study that aimed to contribute to the understanding of SARS-CoV-2 immunity during the evolving course of the pandemic. This study was led by a group of expert member volunteers and resulted in survey data from 975 individuals and blood collection from 698 of those participants. This paper describes the formulation and execution of this large-scale scientific study, encompassing best practices and insights gained throughout the endeavor.
Abstract 12766: Tropsensor: A Rapid Non-Invasive Transdermal Solution For Troponin Measurement
Introduction: Early identification of Acute Myocardial Injury can prompt rapid triage and appropriate interventions to improve clinical outcomes. Over 10 million patients present at the ED with chest-pain, with the majority due to non-cardiac causes, resulting in unnecessary burdens for Emergency Departments (ED). An instant non-invasive method to measure cardiac troponin (cTn) would therefore be of great benefit. Identified need: All Guidelines recommend the use of high sensitivity (HS) cTn for the diagnosis of acute coronary syndromes (ACS). Current biochemical biomarker testing relies on labeling the cTn with turnaround times often an hour or more. Point-of-care solutions reduce the test time, but still depend on the proper handling of samples and blood processing techniques that could lead to difficulties. Tropsensor provides a non-invasive alternative to standard of care (SOC) hs-cTn measurements without the need for a blood draw. The molecular infrared spectroscopy-based transdermal device provides a cTn readout within 5 minutes and allows for serial measurements without any of the delays or complications of blood draws. Methods: A 26-patient (consented and IRB approved) study was conducted at Zuckerberg San Francisco General Hospital with recruitment based on ACS-related presenting symptoms at the ED. Wrist-worn Tropsensor was used on the patients while the corresponding troponin was determined using a high sensitivity (SOC) assay (Siemens ADVIA Centaur) via a blood draw. Results and conclusions: A Pearson’s correlation of 82% with the hs-cTnI was observed. AMI diagnosis sensitivity was 100%, Specificity=50%, PPV=81.8%, NPV=100% and accuracy=84.6%. The Tropsensor modality seems to provide data similar to that of a hs-cTn assay. If so, it would accelerate the assessment of patients presenting with chest pain. By not requiring a blood draw, the Tropsensor could provide a rapid, safe, standardized and reliable source for cTn while allowing bedside serial trending. It thus has the potential to streamline cardiac care workflow by ruling-out many non-cardiac patients and identifying those with high values who are at risk. Such an approach has the potential to facilitate appropriate patient triage towards early discharge of emergent treatment.
T Cell Responses Correlate with Self-Reported Disease Severity and Neutralizing Antibody Responses Predict Protection against SARS-CoV-2 Breakthrough Infection
Objectives: The objective of this prospective study was to investigate the role of adaptive immunity in response to SARS-CoV-2 vaccines. Design and Methods: A cohort of 677 vaccinated individuals participated in a comprehensive survey of their vaccination status and associated side effects, and donated blood to evaluate their adaptive immune responses by neutralizing antibody (NAb) and T cell responses. The cohort then completed a follow-up survey to investigate the occurrence of breakthrough infections. Results: NAb levels were the highest in participants vaccinated with Moderna, followed by Pfizer and Johnson & Johnson. NAb levels decreased with time after vaccination with Pfizer and Johnson & Johnson. T cell responses showed no significant difference among the different vaccines and remained stable up to 10 months after the study period for all vaccine types. In multivariate analyses, NAb responses (<95 U/mL) predicted breakthrough infection, whereas previous infection, the type of vaccine, and T cell responses did not. T cell responses to viral epitopes (<0.120 IU/mL) showed a significant association with the self-reported severity of COVID-19 disease. Conclusion: This study provides evidence that NAb responses to SARS-CoV-2 vaccination correlate with protection against infection, whereas the T cell memory responses may contribute to protection against severe disease but not against infection.
Prognosis is worse with elevated cardiac troponin in nonacute coronary syndrome compared with acute coronary syndrome
Background Cardiac troponin (cTn) can be elevated in many patients presenting to the emergency department (ED) with chest pain but without a diagnosis of acute coronary syndrome (ACS). We compared the prognostic significance of cTn in these different populations. Methods We retrospectively analyzed the CHOPIN study, which enrolled patients who presented to the ED with chest pain. Patients were grouped as ACS, non-ACS cardiovascular disease, noncardiac chest pain and chest pain not otherwise specified (NOS). We examined the prognostic ability of cTnI for the clinical endpoints of mortality and major adverse cardiovascular event (MACE; a composite of acute myocardial infarction, unstable angina, revascularization, reinfarction, and congestive heart failure and stroke) at 180-day follow-up. Results Among 1982 patients analyzed, 14% had ACS, 21% had non-ACS cardiovascular disease, 31% had a noncardiac diagnosis and 34% had chest pain NOS. cTnI elevation above the 99th percentile was observed in 52, 18, 6 and 7% in these groups, respectively. cTnI elevation was associated with mortality and MACE, and their relationships were more prominent in noncardiac diagnosis and chest pain NOS than in ACS and non-ACS cardiovascular diagnoses for mortality, and in non-ACS patients than in ACS patients for MACE (hazard ratio for doubling of cTnI 1.85, 2.05, 8.26 and 4.14, respectively; P for interaction 0.011 for mortality; 1.04, 1.23, 1.54 and 1.42, respectively; P for interaction <0.001 for MACE). Conclusion In patients presenting to the ED with chest pain, cTnI elevation was associated with a worse prognosis in non-ACS patients than in ACS patients.
Sex‐Specific Differences in Clinical Outcomes After Percutaneous Coronary Intervention: Insights from the TAILOR‐PCI Trial
Background TAILOR‐PCI (Tailored Antiplatelet Initiation to Lessen Outcomes due to decreased Clopidogrel Response After Percutaneous Coronary Intervention) studied genotype‐guided selection of antiplatelet therapy after percutaneous coronary intervention versus conventional therapy with clopidogrel. The presence of CYP2C19 loss‐of‐function alleles in patients treated with clopidogrel may be associated with increased risk for ischemic events. We report a prespecified sex‐specific analysis of genotyping and associated cardiovascular outcomes from this study. Methods and Results Associations between sex and major adverse cardiac events (MACE: cardiovascular death, myocardial infarction, stroke, stent thrombosis, and severe recurrent ischemia) and Bleeding Academic Research Consortium (BARC) bleeding at 12 months were analyzed using Cox proportional‐hazards models. Among 5276 randomized patients, loss‐of‐function carriers were observed in ≈36% of both sexes, and >80% of carriers were heterozygotes. At 12 months, after adjustment for baseline differences, risks of MACE (HR , 1.28 [0.97 to 1.68]; P =0.088) and BARC bleeding (hazard ratio [HR], 1.36 [0.91 to 2.05]; P =0.14) were comparable among women and men. There were no significant interactions between sex and treatment strategy for MACE interaction P value ( P int =0.59) or BARC bleeding ( P int =0.47) nor for sex and genotype (MACE P int =0.15, and BARC bleeding P int =0.60). Conclusions CYP2C19 loss‐of‐function alleles were present in ≈1 in 3 women and men. Women had similar adjusted risks of MACE and bleeding as men following percutaneous coronary intervention. Genotype‐guided therapy did not significantly reduce the risk of MACE or bleeding relative to conventional therapy for both sexes. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01742117.
Abstract 13996: Does Copeptin Provide Additional Risk Stratification in Chest Pain Patients With a Mild Troponin Elevation?
Introduction: Copeptin has demonstrated a role in early rule out for acute myocardial infarction in combination with a negative troponin. However, the value of copeptin in patients with a positive troponin is not established. Hypothesis: The addition of a baseline copeptin at chest pain presentation will improve risk stratification in patients with mild troponin elevation. Methods: The multi-center CHOPIN trial enrolled 2071 acute chest pain patients. All subjects with ST segment elevations were excluded from this analysis. Of the remaining patients, 124 had a mildly elevated troponin (defined by < 2x URL) and were included in the study cohort. Baseline cTnI and copeptin levels were drawn on presentation, and another cTnI at 2 hours. Copeptin ≤14 pmol/l and troponin deltas ≤10% from baseline were considered positive. Two independent blinded cardiologists adjudicated AMI diagnosis. The value of a baseline copeptin in this cohort was assessed using AMI incidence, odds ratio, sensitivity, and negative predictive value (NPV). Results: Of the 124 patients in the study cohort, 73 (59%) had an elevated copeptin and an associated AMI incidence of 25% (18 AMIs). The remaining 51 patients (41%) were copeptin negative and diagnosed with 3 AMIs, an incidence of 5.9% (p = 0.006, figure 1). A positive copeptin increased the likelihood of AMI diagnosis with an odds ratio of 5.3 (95% CI: 1.5-19.2). The sensitivity and NPV for AMI were 86% and 94%, both of which were higher than the delta troponin (table 1). When an initial copeptin was combined with the delta troponin the sensitivity and NPV for AMI improved to 100%. Conclusion: Use of copeptin in chest pain patients with mild troponin elevation provides further risk stratification. The combination of copeptin with a delta troponin may aid in earlier AMI rule out in this subset of patients. This approach could be especially relevant as the increasing use of high sensitivity troponin assays leads to greater rates of mild troponin elevations.