Back to Authors

Jaffe, Allan S.

0000-0003-1183-3959

Mayo Clinic

Mayo Clinic

Citations 297

Risk outcome assessment with novel long-T ITC complex and high sensitivity troponin I and T in patients with suspected acute coronary syndromes: MERITnI substudy
Apple, F S, Wagner, Barret P., Sandoval, Yader, Brown, Hannah M. , Miller, Joshua, Sexter, Anne, Schulz, Karen, Jaffe, Allan S., Buda, Kevin G , Buda, Kevin , Wagner, Barrett , Sandoval, Yader , Smith, Stephen W. , Brown, Hannah M., Schulz, Karen , Jaffe, Allan S.

Clinical Chemistry and Laboratory Medicine (CCLM) | July 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1515/cclm-2026-0790 Get It

Abstract Objectives Understanding whether the novel long-T ITC complex might assist in interpreting clinical prognostic utility compared to established cardiac biomarkers is needed. We determined long term major adverse cardiac events (MACE) and all-cause mortality (ACM) predicated on novel long-T ITC complex and high sensitivity cardiac troponin I (hs-cTnI) and T (hs-cTnT) assays in the emergency department (ED). Methods cTn assays were measured on the Mindray CL-1200i platform at presentation in consecutive patients enrolled in ‘Mindray hs-cTnI Assay Analytical and Clinical Evaluation for the Diagnosis and RIsk Assessment of Myocardial InfarctIon’ (MERITnI) (NCT05853042) trial with suspected ischemia. Sex specific 99th percentiles upper reference limits (URLs) were: hs-cTnI female 14 ng/L, male 15 ng/L; hs-cTnT female 10 ng/L, male 19 ng/L; long-T ITC complex 0.9 ng/L, same for female and male. Results Of 1,070 patients, 59.4 % were male, 43.4 % White, 45.5 % Black, and 39.5 % ≥65 years. Independent of biomarkers, a continuum of risk over 1 year showed MACE increased to 16.1 % and ACM to 16.5 %. Long-T ITC complex did not show a continuum change, increasing only 0.1 % (HR: 1.001 (1.0–1.001) per ng/L. However, hs-cTnI increased 1.8 % (HR: 1.018 [1.009–1.027] for each ng/L (p<0.0001) and hs-cTnT increased 0.3 % per ng/L (HR: 1.003 [1.001–1.006]) (p=0.0028). Between subjects ≤URLs and >URLs, MACE and ACM all biomarkers showed significant (p<0.0001) differences over 1 year. For MACE in those >URL long-T ITC complex increased 11.2–25.2 %, hs-cTnI 18.0–35.0 % and hs-cTnT 8.9–24.2 %. For ACM in those >URL long-T ITC complex increased 4.5–23.3 %, hs-cTnI 5.0–26.2 %, and hs-cTnT 3.6–24.1 %. Conclusions Novel long-T ITC complex did not provide new prognostic value to either hs-cTnI or hs-cTnT. Patients with increased hs-cTnI and hs-cTnT concentrations had marked increases in MACE and ACM risk at 1-year.
Distinguishing Acute Myocardial Infarction from Other Forms of Cardiac Injury with the Cardiac Troponin Long-T ITC Complex and High-Sensitivity Troponin I and T in Patients with Suspected Acute Coronary Syndrome: MERITnI Substudy
Apple, Fred S, Wagner, Barret P., Sandoval, Yader, Smith, Stephen W, Brown, Hannah M. , Miller, Joshua R, Sexter, Anne, Schulz, Karen, Jaffe, Allan S, Miller, Joshua R. , Buda, Kevin G , Sandoval, Yader , Brown, Hannah M , Miller, Joshua R , Apple, Fred S. , Buda, Kevin , Wagner, Barrett , Sandoval, Yader , Schulz, Karen , Jaffe, Allan S.

Clinical Chemistry | July 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/clinchem/hvag098 Get It

Abstract Background We determined whether circulating cardiac troponin I–cardiac troponin T–troponin C (ITC) complex containing long-form cardiac troponin T (long-T ITC) complex and ratios of high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT) could differentiate myocardial infarction (MI) from chronic and acute non-MI myocardial injuries in patients with suspected acute coronary syndrome. Methods We measured long-T ITC complex, hs-cTnI, and hs-cTnT (Mindray) at 0- and 2-h in consecutive patients enrolled in the Mindray hs-cTnI Assay Analytical and Clinical Evaluation for the Diagnosis and RIsk Assessment of Myocardial InfarctIon (MERITnI) trial. Results Among the 882 subjects studied (median 3.0 h presentation), 47 had acute MI (5.3%), 116 had acute non-MI myocardial injury, and 90 had chronic myocardial injury. At 0 and 2 h, areas under the curve (AUC) significantly differentiated acute MI from chronic myocardial injury for long-T ITC complex (0.72 and 0.81, respectively; P = 0.0082) but not acute non-MI myocardial injury (AUC, 0.65 and 0.69, respectively; P = 0.23). 0 and 2 h AUCs for long-T ITC complex/hs-cTnT and hs-cTnI/hs-cTnT ratios also significantly differentiated acute MI from chronic myocardial injury (AUC, 0.79 and 0.86, respectively) and acute non-MI myocardial injury (AUC, 0.68 and 0.71, respectively). There was no biomarker concentration or ratio value discrimination between type 1 and type 2 MIs. Conclusions Long-T ITC concentrations and long-T ITC complex/hs-cTnT and hs-cTnI/hs-cTnT ratios may clinically assist in differentiating acute MI from non-MI myocardial injuries when evaluating patients with suspected acute coronary syndrome. ClinicalTrials.gov Registration Number: NCT05853042.
Clinical and Economic Implications of High-Sensitivity Troponin-Informed Admission Strategies in Non-AMI Chest Pain
Chen, Wanyi, Jaffe, Allan S. , Apple, Fred S., deFilippi, Christopher, Peacock, W. Frank , Wu, Alan H. B., Fayyad, Rana, Bethoney, Sarah , Zhang, Jingjing, Boltyenkov, Artem T. , Peacock, William Frank , Chen, Wanyi, Jaffe, Allan S. , Apple, Fred S., deFilippi, Christopher R. , Wu, Alan H.B. , Fayyad, Rana S., Bethoney, Sarah , Zhang, Jingjing, Boltyenkov, Artem

Journal of Cardiovascular Development and Disease | July 14, 2026 | Volume: 13 | Issue: 7 | Pages: 328

10.3390/jcdd13070328 Get It

Most patients with chest pain do not have acute myocardial infarction (AMI), yet post-AMI rule-out disposition remains variable. Detectable but sub-99th percentile high-sensitivity cardiac troponin I (hs-cTnI) provides additional prognostic information. We evaluated the economic value of hs-cTnI-guided hospitalizations among non-AMI patients. We analyzed 1481 non-AMI chest pain visits with detectable baseline hs-cTnI across 29 U.S. emergency departments (2014–2016) in the prospective HIGH-US trial using the Atellica IM TnIH assay(Siemens Healthcare Diagnostics, Tarrytown, NY, US). We compared observed standard-of-care admissions with modeled pathways incorporating hs-cTnI thresholds and risk scores, assessing admission rates, costs, and diagnostic accuracy for 30-day death/MI. Overall, 1.0% (n = 15/1481) experienced 30-day death/MI. Standard-of-care admitted 59% of patients with 93% sensitivity and 41% specificity. The modeled pathway using hs-cTnI ≥ 5 ng/L plus non-low risk scores was associated with reduced projected admission of 41%, higher specificity of 60%, and the same 93% sensitivity. Estimated per-patient diagnostic costs were lower under Scenario 1 (noninvasive diagnostic testing only; $1025 vs. $1139) and under Scenario 2 (including inpatient/invasive procedures; $2672 vs. $3536). In subgroups, higher hs-cTnI thresholds conferred further economic benefit without compromising sensitivity. Incorporating sub-99th percentile hs-cTnI thresholds alongside risk scores may support more efficient resource use while maintaining safety, although findings require prospective validation.
From Pooled Cohorts to PREVENT: A Perspective for Clinical Laboratorians
Pearce, Ryan, Donato, Leslie J. , Vasile, Vlad C. , Jaffe, Allan S. , Meeusen, Jeffrey W. , Donato, Leslie , Jaffe, Allan S.

Clinical Chemistry | July 6, 2026 | Volume: 72 | Issue: 7 | Pages: 814-816

10.1093/clinchem/hvag044 Get It

Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomized trial
Than, Martin , Pickering, John W. , Buchan, Vanessa A, Florkowski, Christopher M , Mills, Nicholas L. , Hamill, Laura , Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika L., Kavsak, Peter, Jaffe, Allan S. , Apple, Fred S. , Cullen, L, Aldous, Sally, Frampton, Christopher MA, Body, Richard, Lord, Sarah Jane, George, Peter Myles, Devlin, Gerard, Kavsak, Peter A. , Mills, Nicholas L , Than, Martin , Pickering, John W , Joyce, Laura R, Buchan, Vanessa, Florkowski, Christopher M , Hamill, Laura, Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika, Kavsak, Peter , Jaffe, Allan S. , Apple, Fred S. , Peacock, William Frank , Cullen, Louise , Aldous, Sally, Richards, Arthur M , Lacey, Cameron, Troughton, Richard W , Frampton, Christopher, Body, Rick , Mueller, Christian , Lord, Sarah, George, Peter M, Devlin, Gerard

No container title available | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.21.26351433 Get It

ABSTRACT BACKGROUND Point-of-care (POC) high-sensitivity cardiac troponin (hs-cTn) testing has the potential to expedite decision-making and reduce emergency department (ED) length of stay for patients presenting with possible myocardial infarction (MI) by ensuring that results are consistently available when looked for by clinicians. We assessed the real-life effectiveness and safety of implementing POC hs-cTn testing in the ED. METHODS We conducted a pragmatic, stepped-wedge cluster randomized trial. The control arm was usual care with an accelerated diagnostic pathway utilizing a single-sample rule-out step with a central laboratory hs-cTn assay. The intervention arm used the same pathway with a POC hs-cTnI. The primary effectiveness outcome was ED length of stay assessed using a generalized linear mixed model, and the safety outcome was 30-day MI or cardiac death. RESULTS Six sites participated with 59,980 ED presentations (44,747 individuals, 61±19 years, 49.5% female) from February 2023 to January 2025, in which 31,392 presentations were during the intervention arm. After adjustment for co-variates associated with length of stay, the intervention reduced length of stay by 13% (95% confidence intervals [CI], 9 to 16%. P<0.001), corresponding to a reduction of 47 minutes (95%CI, 33 to 61 minutes) from a mean length of stay in the control arm of 376 minutes. The 30-day MI or cardiac death rate was similar in the control and intervention arms (0.39% and 0.39% respectively, P=0.54). CONCLUSIONS Implementation of whole-blood hs-cTnI testing at the POC into an accelerated diagnostic pathway was safe and reduced length of stay in the ED compared with laboratory testing. (Australia New Zealand Clinical Trials Registry ACTRN12619001189112) Clinical Perspective What is new? Point-of-care troponin assays with good precision have become available and received regulatory approval as high-sensitivity assays. A pragmatic stepped-wedge cluster randomized trial implementing the validated Siemens VTLi high-sensitivity point-of-care assay into 6 emergency departments investigating ∼60,000 patients, was conducted to ascertain if the rapid turnaround time reduced lengths of stay. Introduction of the VTLi high-sensitivity point-of-care assay into clinical pathways reduced emergency department lengths of stay by an average 13% (47 minutes) without compromising safety. What are the clinical implications? Early decision-making using a point-of-care high-sensitivity troponin assay within a structured clinical pathway was safe. Faster turnaround means troponin results are consistently available when clinicians first seek them. This can facilitate earlier decisions and reduce patient length of stay.
Correlates and Prognostic Value of Serial N‐Terminal Pro‐B‐Type Natriuretic Peptide Assay in Congenitally Corrected Transposition of the Great Arteries
Bahnasy, Ahmed , Bai, Meena , Aboelmaaty, Sara , Ellabbad, Mohamed , Miranda, William R. , Connolly, Heidi M. , Jaffe, Allan S. , Egbe, Alexander C. , Ellabbad, Mohamed , Jaffe, Allan S.

Journal of the American Heart Association | April 9, 2026 | Volume: 15 | Issue: 8 | Pages: No page available

10.1161/jaha.125.046544 Get It

Background Cardiovascular biomarkers such as NT‐proBNP (N‐terminal pro‐B‐type natriuretic peptide) are used for heart failure risk stratification in patients with acquired heart disease, but there are limited data about its role in patients with congenitally corrected transposition of the great arteries. The current study aims to assess the role of serial NT‐proBNP measurements for risk stratification in adults with congenitally corrected transposition of the great arteries. Methods We studied adults with congenitally corrected transposition of the great arteries with ≥2 NT‐proBNP measurements (2003–2024). Temporal change in NT‐proBNP was calculated as relative change from baseline levels. Results Of 152 patients (age 47±13 years, 45% men), baseline NT‐proBNP was 539 (interquartile range, 193–1549) pg/mL, and relative change from baseline levels of NT‐proBNP was 34% (interquartile range, −11 to 67). Of 152 patients, 45 (30%) had cardiovascular events (heart failure hospitalization [n=29], ventricular assist device [n=5], heart transplantation [n=11], and death [n=10]), yielding a 10‐year incidence of 26%. Higher baseline NT‐proBNP and relative change from baseline levels were associated with cardiovascular events. Serial NT‐proBNP measurements had incremental prognostic value compared with baseline measurement. The correlates of higher NT‐proBNP levels were atrial fibrillation, hypertension, right ventricular dilation and dysfunction, and atrioventricular valve regurgitation. Renin–angiotensin–aldosterone system antagonist was associated with lower NT‐proBNP levels and lower risk of cardiovascular events. Conclusions NT‐proBNP testing is inexpensive, widely available, and noninvasive, making it well suited for longitudinal surveillance in adults with congenital heart disease. Most of the correlates for elevated NT‐proBNP levels were modifiable, providing target for therapeutic interventions.
Current and Future Indication for Testing and Use of Cardiac Troponin in Children
Aakre, Kristin M, Jeewa, Aamir, Cullen, Louise , McCrindle, Brian W, Geaghan, Sharon Markham, Apple, F. S., Collinson, Paul O, Hammarsten, Ola , Omland, Torbjørn, Sandoval, Yader, Mills, Nicholas L, Jaffe, A. S., Aakre, Kristin M. , Collinson, Paul , Aakre, Kristin M , Collinson, Paul O , Sandoval, Yader , Mills, Nicholas L , Cullen, Louise , Jeewa, Aamir , McCrindle, Brian W. , Decrue, Fabienne , Apple, Fred S. , Omland, Torbjørn , Sandoval, Yader , Jaffe, Allan S.

Clinical Chemistry | March 27, 2026 | Volume: 72 | Issue: 6 | Pages: 625-640

10.1093/clinchem/hvag021 Get It

Abstract Background The clinical use and interpretation of cardiac troponins (cTn) in pediatric patients is heterogeneous. Content This review is based on an appraisal and synthesis of the available literature and discussions between International Federation of Clinical Chemistry and Laboratory Medicine Committee on Clinical Application of Cardiac Biomarkers members and pediatricians, cardiologists, emergency department physicians, and laboratorians. It aims to summarize current knowledge and best practices related to cTn measurements in pediatric patients, including which percentile should be applicable as the upper reference limit, and the influence of age, sex, and physiology on circulating concentrations. Preanalytical and analytical precautions, and a consensus on optimal interpretation of the reported results are discussed. Summary Current studies report high cTn concentrations in healthy infants and newborns. The nadir is reached at 1–3 years at which time concentrations gradually increase, reaching adult levels through puberty. The incidence of myocardial injury is reported to be low and dependent on whether the 97.5th or 99th percentile is chosen as the upper reference limit. The main clinical indication for testing appears to be suspicion of myo/pericarditis or traumatic chest injury. On occasion, cTn is measured in cases of possible heart failure and/or myocardial ischemia. There is heterogeneity among the limited clinical studies published. Most of the data are retrospective, and the current suggestions for clinical practice are thus largely based on expert opinion. More research is needed regarding all aspects of cTn testing in children, and suggestions for future research are included at the end of this review.
Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 Assay
Knoll, Marko, Daniels, Lori B. , Mueller, Christian, Mills, Nicholas L, Giannitsis, Evangelos, Rösser, Alisa F A, Kurtoic, Dunja, Wahl, Annika , BODY, R. A. F., Christenson, R H, Cobbaert, Christa, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A. S., McCarthy, C. F., McCord, James, Neumann, Johannes T, Omland, Torbjørn, Papendick, Cynthia , Sandoval, Yader, Than, Martin P, Twerenbold, Raphael, Peacock, W Frank, Meex, Steven J. R., Giannitsis, Evangelos , Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mills, Nicholas L. , Mueller, Christian , Mills, Nicholas L , Giannitsis, Evangelos , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Daniels, Lori B , Cobbaert, Christa M. , deFilippi, Christopher R. , McCarthy, Cian P, McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Meex, Steven J.R.

The Journal of Applied Laboratory Medicine | March 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag031 Get It

Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Considerations and pragmatic strategies for implementation of point of care testing for high sensitivity cardiac troponin into the acute care setting
Collinson, Paul, Christenson, Robert, Jafri, Lena , Jaffe, Allan S., Apple, Fred S. , Hammarsten, Ola , Omland, Torbjørn, Sandoval, Yader, Mills, Nicholas L., Buchan, Vanessa, Sandberg, Sverre , Aakre, Kristin M., Aakre, Kristin M , Collinson, Paul , Lam, Leo , Pickering, John W. , Christenson, Robert H. , Hoovels, Lieve Van , Cullen, Louise , Jaffe, Allan S. , Omland, Torbjørn , Sandoval, Yader , Mills, Nicholas L , Than, Martin , Aakre, Kristin M.

Clinical Chemistry and Laboratory Medicine (CCLM) | March 5, 2026 | Volume: 64 | Issue: 7 | Pages: 1467-1478

10.1515/cclm-2026-0210 Get It

Abstract A challenge in the implementation of rapid risk-stratification algorithms for patients with suspected acute coronary syndrome is the turnaround time for cardiac troponin (cTn) from blood sampling to reporting of results. Measurement of cTn in whole blood using point of care (POC) offers a solution. There is lack of consensus on how these instruments should be assessed and deployed when implemented into routine practice. A pragmatic strategy is needed to balance the requirement for appropriate evaluation, validation and local verification of POC high sensitivity (hs) cTn assays whilst avoiding unnecessary duplication of previously conducted work using central laboratory assays. The International Federation of Clinical Chemistry and Laboratory Medicine Committee on Clinical Application of Cardiac Bio-Markers (IFCC C-CB) has developed an educational document to provide practical suggestions as to how hs-cTn POC assays may be implemented in acute health care settings and networks. The objective of this document is to provide a pragmatic framework for implementation of such systems. The article describes the validation and verification procedures and outlines what should be the responsibility of the manufacturers and provides recommendations on how a local verification may be undertaken before instruments are implemented into routine clinical practice.
Letter by Jaffe et al Regarding Article, “Disrupting the Status Quo: Reimagining How We Use Troponin for Diagnosing Myocardial Infarction”
Sandoval, Yader, Apple, Fred S. , Jaffe, A S, Sandoval, Yader , Jaffe, Allan S. , Sandoval, Yader

Circulation: Population Health and Outcomes | February 16, 2026 | Volume: 19 | Issue: 4 | Pages: No page available

10.1161/circoutcomes.125.012948 Get It