Back to Authors

Hamill, Laura

https://orcid.org/0000-0002-8829-9224

Mayo Clinic

Christchurch Hospital

Citations 1

Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomized trial
Than, Martin , Pickering, John W. , Buchan, Vanessa A, Florkowski, Christopher M , Mills, Nicholas L. , Hamill, Laura , Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika L., Kavsak, Peter, Jaffe, Allan S. , Apple, Fred S. , Cullen, L, Aldous, Sally, Frampton, Christopher MA, Body, Richard, Lord, Sarah Jane, George, Peter Myles, Devlin, Gerard, Kavsak, Peter A. , Mills, Nicholas L , Than, Martin , Pickering, John W , Joyce, Laura R, Buchan, Vanessa, Florkowski, Christopher M , Hamill, Laura, Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika, Kavsak, Peter , Jaffe, Allan S. , Apple, Fred S. , Peacock, William Frank , Cullen, Louise , Aldous, Sally, Richards, Arthur M , Lacey, Cameron, Troughton, Richard W , Frampton, Christopher, Body, Rick , Mueller, Christian , Lord, Sarah, George, Peter M, Devlin, Gerard

No container title available | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.21.26351433 Get It

ABSTRACT BACKGROUND Point-of-care (POC) high-sensitivity cardiac troponin (hs-cTn) testing has the potential to expedite decision-making and reduce emergency department (ED) length of stay for patients presenting with possible myocardial infarction (MI) by ensuring that results are consistently available when looked for by clinicians. We assessed the real-life effectiveness and safety of implementing POC hs-cTn testing in the ED. METHODS We conducted a pragmatic, stepped-wedge cluster randomized trial. The control arm was usual care with an accelerated diagnostic pathway utilizing a single-sample rule-out step with a central laboratory hs-cTn assay. The intervention arm used the same pathway with a POC hs-cTnI. The primary effectiveness outcome was ED length of stay assessed using a generalized linear mixed model, and the safety outcome was 30-day MI or cardiac death. RESULTS Six sites participated with 59,980 ED presentations (44,747 individuals, 61±19 years, 49.5% female) from February 2023 to January 2025, in which 31,392 presentations were during the intervention arm. After adjustment for co-variates associated with length of stay, the intervention reduced length of stay by 13% (95% confidence intervals [CI], 9 to 16%. P<0.001), corresponding to a reduction of 47 minutes (95%CI, 33 to 61 minutes) from a mean length of stay in the control arm of 376 minutes. The 30-day MI or cardiac death rate was similar in the control and intervention arms (0.39% and 0.39% respectively, P=0.54). CONCLUSIONS Implementation of whole-blood hs-cTnI testing at the POC into an accelerated diagnostic pathway was safe and reduced length of stay in the ED compared with laboratory testing. (Australia New Zealand Clinical Trials Registry ACTRN12619001189112) Clinical Perspective What is new? Point-of-care troponin assays with good precision have become available and received regulatory approval as high-sensitivity assays. A pragmatic stepped-wedge cluster randomized trial implementing the validated Siemens VTLi high-sensitivity point-of-care assay into 6 emergency departments investigating ∼60,000 patients, was conducted to ascertain if the rapid turnaround time reduced lengths of stay. Introduction of the VTLi high-sensitivity point-of-care assay into clinical pathways reduced emergency department lengths of stay by an average 13% (47 minutes) without compromising safety. What are the clinical implications? Early decision-making using a point-of-care high-sensitivity troponin assay within a structured clinical pathway was safe. Faster turnaround means troponin results are consistently available when clinicians first seek them. This can facilitate earlier decisions and reduce patient length of stay.