Abstract A challenge in the implementation of rapid risk-stratification algorithms for patients with suspected acute coronary syndrome is the turnaround time for cardiac troponin (cTn) from blood sampling to reporting of results. Measurement of cTn in whole blood using point of care (POC) offers a solution. There is lack of consensus on how these instruments should be assessed and deployed when implemented into routine practice. A pragmatic strategy is needed to balance the requirement for appropriate evaluation, validation and local verification of POC high sensitivity (hs) cTn assays whilst avoiding unnecessary duplication of previously conducted work using central laboratory assays. The International Federation of Clinical Chemistry and Laboratory Medicine Committee on Clinical Application of Cardiac Bio-Markers (IFCC C-CB) has developed an educational document to provide practical suggestions as to how hs-cTn POC assays may be implemented in acute health care settings and networks. The objective of this document is to provide a pragmatic framework for implementation of such systems. The article describes the validation and verification procedures and outlines what should be the responsibility of the manufacturers and provides recommendations on how a local verification may be undertaken before instruments are implemented into routine clinical practice.
Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference
Abstract This paper, prepared by the EFLM Task and Finish Group on Allocation of laboratory tests to different models for performance specifications (TFG-DM), is dealing with criteria for allocating measurands to the different models for analytical performance specifications (APS) recognized in the 1st EFLM Strategic Conference Consensus Statement. Model 1, based on the effect of APS on clinical outcome, is the model of choice for measurands that have a central role in the decision-making of a specific disease or clinical situation and where cut-off/decision limits are established for either diagnosing, screening or monitoring. Total cholesterol, glucose, HbA 1c , serum albumin and cardiac troponins represent practical examples. Model 2 is based on components of biological variation and should be applied to measurands that do not have a central role in a specific disease or clinical situation, but where the concentration of the measurand is in a steady state. This is best achieved for measurands under strict homeostatic control in order to preserve their concentrations in the body fluid of interest, but it can also be applied to other measurands that are in a steady state in biological fluids. In this case, it is expected that the “noise” produced by the measurement procedure will not significantly alter the signal provided by the concentration of the measurand. This model especially applies to electrolytes and minerals in blood plasma (sodium, potassium, chloride, bicarbonate, calcium, magnesium, inorganic phosphate) and to creatinine, cystatin C, uric acid and total protein in plasma. Model 3, based on state-of-the-art of the measurement, should be used for all the measurands that cannot be included in models 1 or 2.
Current Issues in Measurement and Reporting of Urinary Albumin Excretion
Abstract Background: Urinary excretion of albumin indicates kidney damage and is recognized as a risk factor for progression of kidney disease and cardiovascular disease. The role of urinary albumin measurements has focused attention on the clinical need for accurate and clearly reported results. The National Kidney Disease Education Program and the IFCC convened a conference to assess the current state of preanalytical, analytical, and postanalytical issues affecting urine albumin measurements and to identify areas needing improvement. Content: The chemistry of albumin in urine is incompletely understood. Current guidelines recommend the use of the albumin/creatinine ratio (ACR) as a surrogate for the error-prone collection of timed urine samples. Although ACR results are affected by patient preparation and time of day of sample collection, neither is standardized. Considerable intermethod differences have been reported for both albumin and creatinine measurement, but trueness is unknown because there are no reference measurement procedures for albumin and no reference materials for either analyte in urine. The recommended reference intervals for the ACR do not take into account the large intergroup differences in creatinine excretion (e.g., related to differences in age, sex, and ethnicity) nor the continuous increase in risk related to albumin excretion. Discussion: Clinical needs have been identified for standardization of (a) urine collection methods, (b) urine albumin and creatinine measurements based on a complete reference system, (c) reporting of test results, and (d) reference intervals for the ACR.