Back to Authors

Bunk, David M.

https://orcid.org/0000-0001-9838-7626

Mayo Clinic

NIST, Gaithersburg, MD

Citations 2

Recommendations for the Generation, Quantification, Storage, and Handling of Peptides Used for Mass Spectrometry–Based Assays
Hoofnagle, Andrew N. , Carr, Steven A. , Liu, Tao , Massoni, Sam A., Thomas, Stefani N. , Townsend, R. Reid , Zimmerman, Lisa J. , Boja, Emily S. , Chen, Jing , Crimmins, Daniel L., Davies, Sherri R. , Hiltke, Tara , Ketchum, Karen A. , Kinsinger, Christopher R. , Mesri, Mehdi , Meyer, Matthew R. , Qian, Weijun , Schoenherr, Regine M., Scott, Mitchell G., Shi, Tujin , Whiteley, Gordon , Wrobel, John A. , Wu, Chaochao, Ackermann, Brad, Barnidge, David R. , Bunk, David M. , Clarke, Nigel J. , Fishman, Jordan B., Grant, Russ P., Kushnir, Mark M. , Lowenthal, Mark S. , Neubert, Hendrik , Patterson, Scott D. , Rockwood, Alan L. , Rogers, John , Eyk, Jennifer E. Van , Wong, Steven, Zhang, Shucha, Chan, Daniel W. , Chen, Xian , Liebler, D.C. , Rodland, Karin , Rodriguez, Henry , Paulovich, Amanda G. , Whiteaker, Jeffrey R. , Kuhn, Eric W. , Gao, Yuqian , Aebersold, Ruedi , Grant, Russell P. , Kusebauch, Ulrike , Moritz, Robert L. , Singh, Ravinder J. , Ellis, Matthew J. , Smith, Richard , Zhang, Zhen , Zhang, Hui , Davies, S. J.

Clinical Chemistry | December 30, 2015 | Volume: 62 | Issue: 1 | Pages: 48-69

10.1373/clinchem.2015.250563 Get It

AbstractBACKGROUNDFor many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope–labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays.CONTENTThe Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials—in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry—is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.
Current Issues in Measurement and Reporting of Urinary Albumin Excretion
Miller, W. Greg , Bruns, David E., Hortin, Glen L. , Sandberg, Sverre , Aakre, Kristin M. , McQueen, Matthew, Itoh, Yoshihisa, Seccombe, David , Jones, Graham , Bunk, David M. , Narva, Andrew S., Urine, on behalf of the National Kidney Disease Education Program-IFCC Working Group on Standardization of Albumin in, Lieske, John C. , Curhan, Gary C. , Urine, on behalf of the National Kidney Disease Education Program-IFCC Working Group on Standardization of Albumin in, Aakre, Kristin M

Clinical Chemistry | November 21, 2008 | Volume: 55 | Issue: 1 | Pages: 24-38

10.1373/clinchem.2008.106567 Get It

Abstract Background: Urinary excretion of albumin indicates kidney damage and is recognized as a risk factor for progression of kidney disease and cardiovascular disease. The role of urinary albumin measurements has focused attention on the clinical need for accurate and clearly reported results. The National Kidney Disease Education Program and the IFCC convened a conference to assess the current state of preanalytical, analytical, and postanalytical issues affecting urine albumin measurements and to identify areas needing improvement. Content: The chemistry of albumin in urine is incompletely understood. Current guidelines recommend the use of the albumin/creatinine ratio (ACR) as a surrogate for the error-prone collection of timed urine samples. Although ACR results are affected by patient preparation and time of day of sample collection, neither is standardized. Considerable intermethod differences have been reported for both albumin and creatinine measurement, but trueness is unknown because there are no reference measurement procedures for albumin and no reference materials for either analyte in urine. The recommended reference intervals for the ACR do not take into account the large intergroup differences in creatinine excretion (e.g., related to differences in age, sex, and ethnicity) nor the continuous increase in risk related to albumin excretion. Discussion: Clinical needs have been identified for standardization of (a) urine collection methods, (b) urine albumin and creatinine measurements based on a complete reference system, (c) reporting of test results, and (d) reference intervals for the ACR.