Back to Authors

Giannitsis, Evangelos

0000-0002-1025-2872

Mayo Clinic

Department of Internal Medicine III, Cardiology University Hospital of Heidelberg, Heidelberg, Germany.

Citations 2

Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 Assay
Knoll, Marko, Daniels, Lori B. , Mueller, Christian, Mills, Nicholas L, Giannitsis, Evangelos, Rösser, Alisa F A, Kurtoic, Dunja, Wahl, Annika , BODY, R. A. F., Christenson, R H, Cobbaert, Christa, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A. S., McCarthy, C. F., McCord, James, Neumann, Johannes T, Omland, Torbjørn, Papendick, Cynthia , Sandoval, Yader, Than, Martin P, Twerenbold, Raphael, Peacock, W Frank, Meex, Steven J. R., Giannitsis, Evangelos , Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mills, Nicholas L. , Mueller, Christian , Mills, Nicholas L , Giannitsis, Evangelos , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Daniels, Lori B , Cobbaert, Christa M. , deFilippi, Christopher R. , McCarthy, Cian P, McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Meex, Steven J.R.

The Journal of Applied Laboratory Medicine | March 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag031 Get It

Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
High-sensitivity point-of-care measurement of cardiac troponin
Cullen, Louise , Mair, Johannes , Hammarsten, Ola , Boeddinghaus, Jasper , Daniels, Lori B. , Huber, Kurt , Giannitsis, Evangelos , Jaffe, Allan S. , Kimenai, Dorien M , Möckel, Martin , Mueller, Christian, Thielmann, Matthias , Thygesen, Kristian , Mills, Nicholas L. , Boeddinghaus, Jasper , Daniels, Lori B , Giannitsis, Evangelos , Kimenai, Dorien M , Lindahl, Bertil , Mockel, Martin , Thielmann, Matthias , Thygesen, Kristian , Mills, Nicholas L , Cullen, Louise , Stengaard, Carsten , Jaffe, Allan S. , Krychtiuk, Konstantin A , Lindahl, Bertil

European Heart Journal | June 4, 2025 | Volume: 47 | Issue: 12 | Pages: 1392-1402

10.1093/eurheartj/ehaf407 Get It

Abstract New technologies enabling access to high-sensitivity cardiac troponin (hs-cTn) assays at the point of care (POC) are available for routine use. POC technology can accelerate cardiac troponin testing within the hospital setting and support testing in other healthcare environments. Pre-analytical and analytical issues unique to POC testing are discussed. The opportunities and the evidence needed to support the routine use of hs-cTn POC assays in clinical care are outlined. Based on recent developments, the potential impact of hs-cTn at the POC in multiple clinical settings is described, and a roadmap of the steps required for successful implementation is provided.