Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
The assessment and management of patients with type 2 myocardial infarction: an international Delphi study
Abstract Aims Type 2 myocardial infarction due to myocardial oxygen supply–demand imbalance is associated with poor outcomes. There are no guidelines to inform care for these patients. The consensus on the assessment and management of type 2 myocardial infarction is gained. Methods and results An international e-Delphi study including experts in type 2 myocardial infarction identified through systematic review was conducted. Participants were asked to describe their approach to (i) definition and diagnosis, (ii) risk stratification, (iii) assessment of coronary artery disease and cardiac function, (iv) specialty management, (v) treatment and secondary prevention, and (vi) communication and rehabilitation. Statements generated in round one were circulated, with consensus defined a priori as ≥70% agreement on a 5-point Likert scale. Where no consensus was reached, statements were amended and recirculated for a final round. The response rate was 56% (38/68), 54% (37/68), and 72% (49/68) in the first, second, and third rounds, respectively. Following the first round, 67 unique statements were generated across six domains. Overall, consensus was achieved on 64% (43/67) of statements. Consensus was achieved for 42% (5/12) of statements on the diagnosis of type 2 myocardial infarction, 75% (3/4) on risk stratification, 50% (9/18) on the assessment of coronary artery disease and cardiac function, 60% (6/10), on specialty management, 100% (9/9) on treatment and secondary prevention, and 79% (11/15) on communication and rehabilitation. Conclusion Consensus was obtained across a number of domains for the assessment and management of patients with type 2 myocardial infarction. However, there was limited agreement amongst experts on the diagnostic criteria, which may benefit from refinement.
Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection
BACKGROUND A rise or fall of cardiac troponin is a prerequisite for the diagnosis of acute myocardial infarction. Defining significant changes requires knowledge of both biological and analytical variation. The short-term biological variation of cardiac troponin in healthy individuals is 3%–48%. However, healthy individuals may not be representative for patients in whom cardiac troponin measurement is often of clinical importance. Therefore, we studied the individual variation of cardiac troponin in patients with symptoms of stable coronary artery disease. METHODS Twenty-four patients scheduled for elective coronary angiography were included. Blood samples were drawn once at enrollment and serially at six 4-h intervals on the day before coronary angiography. Cardiac troponin was measured with hs-cTn assays from Abbott Laboratories (premarket cTnI assay) and Roche Diagnostics (Elecsys® cTnT assay with two different lots). RESULTS The short-term individual variation in cardiac troponin I (cTnI) was 14%, the reference change value (RCV) 49%, and RCV-log-normal (rise/fall) 54%/−35%. The corresponding values for cTnT were 7%, 23%, and 26%/−21%. The long-term variation for cTnI was 24%, RCV 69%, and RCV-log-normal (rise/fall) 97%/−49%. The corresponding values for cTnT were 11%, 32%, and 37%/−27%. CONCLUSIONS The short-term individual variation of cardiac troponin in patients with symptoms of stable coronary artery disease is similar to the biological variation previously demonstrated in healthy individuals. Our results suggest that a change in cardiac troponin concentrations of >50% can be used in attempting to diagnose acute myocardial injury. To detect significant long-term changes in cardiac troponin concentrations, larger changes will be required.