Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Air Embolism: Diagnosis, Clinical Management and Outcomes
Air embolism is a rare but potentially fatal complication of surgical procedures. Rapid recognition and intervention is critical for reducing morbidity and mortality. We retrospectively characterized our experience with air embolism during medical procedures at a tertiary medical center. Electronic medical records were searched for all cases of air embolism over a 25-year period; relevant medical and imaging records were reviewed. Sixty-seven air embolism cases were identified; the mean age was 59 years (range, 3–89 years). Ninety-four percent occurred in-hospital, of which 77.8% were during an operation/invasive procedure. Vascular access-related procedures (33%) were the most commonly associated with air embolism. Clinical signs and symptoms were related to the location the air embolus; 36 cases to the right heart/pulmonary artery, 21 to the cerebrum, and 10 were attributed to patent foramen ovale (PFO). Twenty-one percent of patients underwent hyperbaric oxygen therapy (HBOT), 7.5% aspiration of the air, and 63% had no sequelae. Mortality rate was 21%; 69% died within 48 hours. Thirteen patients had immediate cardiac arrest where mortality rate was 53.8%, compared to 13.5% (p = 0.0035) in those without. Air emboli were mainly iatrogenic, primarily associated with endovascular procedures. High clinical suspicion and early treatment are critical for survival.
Air Embolism: Practical Tips for Prevention and Treatment
Air embolism is a rarely encountered but much dreaded complication of surgical procedures that can cause serious harm, including death. Cases that involve the use of endovascular techniques have a higher risk of air embolism; therefore, a heightened awareness of this complication is warranted. In particular, central venous catheters and arterial catheters that are often placed and removed in most hospitals by a variety of medical practitioners are at especially high risk for air embolism. With appropriate precautions and techniques it can be preventable. This article reviews the causes of air embolism, clinical management and prevention techniques.