Back to Authors

Tan, Jack Wei Chieh

https://orcid.org/0000-0003-2181-4313

Mayo Clinic

Duke-NUS Medical School

Citations 3

Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 Assay
Knoll, Marko, Daniels, Lori B. , Mueller, Christian, Mills, Nicholas L, Giannitsis, Evangelos, Rösser, Alisa F A, Kurtoic, Dunja, Wahl, Annika , BODY, R. A. F., Christenson, R H, Cobbaert, Christa, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A. S., McCarthy, C. F., McCord, James, Neumann, Johannes T, Omland, Torbjørn, Papendick, Cynthia , Sandoval, Yader, Than, Martin P, Twerenbold, Raphael, Peacock, W Frank, Meex, Steven J. R., Giannitsis, Evangelos , Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mills, Nicholas L. , Mueller, Christian , Mills, Nicholas L , Giannitsis, Evangelos , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Daniels, Lori B , Cobbaert, Christa M. , deFilippi, Christopher R. , McCarthy, Cian P, McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Meex, Steven J.R.

The Journal of Applied Laboratory Medicine | March 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag031 Get It

Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Daniels, Lori B. , Mueller, Christian, Giannitsis, Evangelos, Meex, Steven J. R., Buehlmann, David, Dilba, Peter, Bendig, Garnet, Cole, Mette, Body, Richard, Christenson, Robert H, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A S, McCarthy, Cian P. , McCord, J., Neumann, Johannes T, Omland, T., Papendick, Cynthia , Sandoval, Yader, Twerenbold, Raphael, Peacock, W Frank, Mills, Nicholas L, investigators, the TSIX, Jacobs, Michael B., Lucksinger, Gregg, Powell, Richard, Johnson, Daniel, Coleman, Hugh, Fein, M, Surber, Joseph, Vu, Jack B., Hassman, Michael, Hernandez, John, Kirstein, Judith, Tomaszewski, Christian, Runyon, Michael S. , Gong, Jonathan , Wein, D., Andrabi, Sara , Kopin, David , Larrain, Germain, Tahirkheli, Naheem, Clemency, Brian, Abdullah, Shuaib, Hira, Ravi S. , Klausner, H A, Mahler, Simon A. , Crystal, Chad, Headden, Gary, Chaille, Peter, Cannon, Chad Aaron, Limkakeng, Alexander, Tolia, Vaishal , Knapp, Barry J., Massoomi, Mohammad, Sandoval, Yader, Ko, Emily, Luzzi, Verónica, Christenson, Robert, Carson, Jennifer Powers , Cacioppo, F , Kolev, E., Petrov, Andrey, Hazarbasanov, Dobri , Simova, lana, Magimaiseelan, Luci Suganthi, Kosch, Christine, Klein, G, Mehltretter, Kai, Sauter, Joachim, Baumann, Sybille, Moeckel, Martin, Twerenbold, Raphael, Muller-Hennessen, Matthias, Biener, Moritz , Findeisen, P., Omland, Torbjøm, Wilczek-Kosowska, Urszula, Zimmer-Satora, Ewa, Krecipro-Nizińska, Ewa, Miró, O, Díaz, Víctor Jiménez , Mueller, C, Christ, Michael, Lynch, Stephen, BODY, R. A. F., Matsuki, Shunji, Eto, Takashi, Tanaka, Takanori, Hanada, Ryuzo, Nakagami, Takuo, Nakama, T, Kadota, K., Jing, Shan, Yu, Shuwen, Zhang, Hongxuan, Zhang, Jun, Huo, Yong, Zhang, Yan, Yan, Li, Jiang, Longyuan, Chen, Weiqiang, Huang, Jianying, Zhao, Yan, Guan, Ling, Yang, Yanhua, Zhang, Qin, Qiu, Zhaohui, Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mueller, Christian , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Mills, Nicholas L , Daniels, Lori B , Giannitsis, Evangelos , Meex, Steven J.R. , Christenson, Robert H. , Cobbaert, Christa M. , deFilippi, Christopher R. , McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Surber, Joseph, Tomaszewski, Christian, Clemency, Brian, Headden, Gary , Cannon, Chad, Knapp, Barry , Tran, Nam K , Niederdöckl, Jan Daniel , Kolev, Emil, Popov, Todor, Sauter, Joachim, Baumann, Sybille , Möeckel, Martin , Müller‐Hennessen, Matthias, Findeisen, Peter, Scharnhorst, Volkher , Omland, T, Krecipro-Nizińska, Ewa, Christ, Michael , Nakagami, Takuo, Huo, Yong

Clinical Chemistry | January 18, 2026 | Volume: 72 | Issue: 4 | Pages: 488-502

10.1093/clinchem/hvag011 Get It

Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
Asian Pacific Society of Cardiology Consensus Statements on the Use of Percutaneous Coronary Intervention on Stenosis of the Left Main Coronary Artery
Tan, Jack Wei Chieh , Tan, Huay Cheem , Lee, Michael , Seth, Ashok , Sin, Kenny YK, Firman, Doni , Yap, Jonathan , Sison, Eric Oliver D, Yahya, Achmad Fauzi , Chan, Kok Meng, Chan, Howard Ho Yan, Murasato, Yoshinobu , Malik, Fazila‐Tun‐Nesa , Nguyen, Michael C., Zhang, Bin , Kim, Hyo-Soo , Nguyen, Quang Ngoc , Ako, Junya , Bhindi, Ravinay, Zhang, Junjie , Tam, Frankie Chor-Cheung, Sengottuvelu, G., Ramaiah, Asri Ranga Bin Abdullah, Ali, Rosli Bin Mohd, Harding, S. , Wong, Aaron Sung Lung , Loh, Poay Huan , Hsieh, I-Chang , Kehasukcharoen, Wirash , Linh, Dinh Huynh, Henry, Timothy D. , Tan, Jack Wei Chieh , Lo, Sidney, Sin, Kenny Yoong Kong , Park, Duk‐Woo , Chan, Kok Meng John, Chan, Ho Yan Howard, Nguyen, Michael C, Lee, Kwan , Santoso, Teguh Iman , Wongpraparut, Nattawut , Ramaiah, Asri Ranga Abdullah, Yeo, Khung Keong , Stankovic, Goran R.

Journal of Asian Pacific Society of Cardiology | October 2, 2024 | Volume: 3 | Issue: No issue available | Pages: No page available

10.15420/japsc.2024.27 Get It

Stenosis of the left main coronary artery (LM stenosis) is associated with significant mortality and morbidity due to the large area of affected myocardium. Evidence on the use of percutaneous coronary intervention (PCI) for the treatment of LM stenosis is growing. However, the role of Western guidelines on patients in the Asian-Pacific region is unclear due to anatomical variations, substantial heterogeneity in healthcare resources and infrastructure, and the lack of consensus on the optimal management of LM stenosis in the Asia-Pacific region. Hence, an Asian Pacific Society of Cardiology (APSC) working group developed consensus recommendations on the use of PCI in the management of LM stenosis in the Asia-Pacific region. The APSC expert panel reviewed and appraised the available evidence using the Grading of Recommendations Assessment, Development, and Evaluation system. Consensus recommendations were developed and put to an online vote. Consensus was reached when 80% of votes for a given recommendation were in support of ‘agree’ or ‘neutral’. The resulting 12 statements provide guidance for clinical practitioners in the region on the use of PCI in the treatment of patients with LM stenosis.