Back to Authors

Headden, Gary

https://orcid.org/0000-0002-5680-7191

Mayo Clinic

Medical University of South Carolina

Citations 4

Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Daniels, Lori B. , Mueller, Christian, Giannitsis, Evangelos, Meex, Steven J. R., Buehlmann, David, Dilba, Peter, Bendig, Garnet, Cole, Mette, Body, Richard, Christenson, Robert H, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A S, McCarthy, Cian P. , McCord, J., Neumann, Johannes T, Omland, T., Papendick, Cynthia , Sandoval, Yader, Twerenbold, Raphael, Peacock, W Frank, Mills, Nicholas L, investigators, the TSIX, Jacobs, Michael B., Lucksinger, Gregg, Powell, Richard, Johnson, Daniel, Coleman, Hugh, Fein, M, Surber, Joseph, Vu, Jack B., Hassman, Michael, Hernandez, John, Kirstein, Judith, Tomaszewski, Christian, Runyon, Michael S. , Gong, Jonathan , Wein, D., Andrabi, Sara , Kopin, David , Larrain, Germain, Tahirkheli, Naheem, Clemency, Brian, Abdullah, Shuaib, Hira, Ravi S. , Klausner, H A, Mahler, Simon A. , Crystal, Chad, Headden, Gary, Chaille, Peter, Cannon, Chad Aaron, Limkakeng, Alexander, Tolia, Vaishal , Knapp, Barry J., Massoomi, Mohammad, Sandoval, Yader, Ko, Emily, Luzzi, Verónica, Christenson, Robert, Carson, Jennifer Powers , Cacioppo, F , Kolev, E., Petrov, Andrey, Hazarbasanov, Dobri , Simova, lana, Magimaiseelan, Luci Suganthi, Kosch, Christine, Klein, G, Mehltretter, Kai, Sauter, Joachim, Baumann, Sybille, Moeckel, Martin, Twerenbold, Raphael, Muller-Hennessen, Matthias, Biener, Moritz , Findeisen, P., Omland, Torbjøm, Wilczek-Kosowska, Urszula, Zimmer-Satora, Ewa, Krecipro-Nizińska, Ewa, Miró, O, Díaz, Víctor Jiménez , Mueller, C, Christ, Michael, Lynch, Stephen, BODY, R. A. F., Matsuki, Shunji, Eto, Takashi, Tanaka, Takanori, Hanada, Ryuzo, Nakagami, Takuo, Nakama, T, Kadota, K., Jing, Shan, Yu, Shuwen, Zhang, Hongxuan, Zhang, Jun, Huo, Yong, Zhang, Yan, Yan, Li, Jiang, Longyuan, Chen, Weiqiang, Huang, Jianying, Zhao, Yan, Guan, Ling, Yang, Yanhua, Zhang, Qin, Qiu, Zhaohui, Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mueller, Christian , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Mills, Nicholas L , Daniels, Lori B , Giannitsis, Evangelos , Meex, Steven J.R. , Christenson, Robert H. , Cobbaert, Christa M. , deFilippi, Christopher R. , McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Surber, Joseph, Tomaszewski, Christian, Clemency, Brian, Headden, Gary , Cannon, Chad, Knapp, Barry , Tran, Nam K , Niederdöckl, Jan Daniel , Kolev, Emil, Popov, Todor, Sauter, Joachim, Baumann, Sybille , Möeckel, Martin , Müller‐Hennessen, Matthias, Findeisen, Peter, Scharnhorst, Volkher , Omland, T, Krecipro-Nizińska, Ewa, Christ, Michael , Nakagami, Takuo, Huo, Yong

Clinical Chemistry | January 18, 2026 | Volume: 72 | Issue: 4 | Pages: 488-502

10.1093/clinchem/hvag011 Get It

Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
Multicenter Evaluation of a New Strip-Based Blood Glucose System for Point-of-Care Testing in Critical and Non-Critical Care Settings
Goodman, Michael D. , Bercker, Sven , Breitenbeck, Nancy, Cañada-Vilalta, C., Canepa, Daisy D., Clarke, William , Ganser, Edward O., Geerts, Nienke, Goldsmith, Barbara, Headden, Gary , Hoppensteadt, Debra, Klapperich, Birgit, Matika, Ryan W., Miles, Gabrielle, Mukhopadhyay, Sagori , O’Dell, Rebecca M., Rafique, Zubaid , Schuetzenmeister, Andre, Stankiewicz, Ann F., Swanson, Jonathan R. , Wu, Alan H.B. , Karon, Brad S. , Goodman, Michael , Nichols, James H , Tran, Nam K , Wu, Alan H B , Canepa, Daisy D., Farnsworth, Christopher W , Hoppensteadt, Debra , Nichols, James H. , O’Dell, Rebecca M., Schützenmeister, André , Slingerland, Robbert Jan , Stankiewicz, Ann F.

Journal of Diabetes Science and Technology | May 31, 2025 | Volume: 20 | Issue: 4 | Pages: 1322-1331

10.1177/19322968251325873 Get It

Background: Evaluation of the performance of Cobas ® Pulse (Roche Diagnostics GmbH, Mannheim, Germany), a new blood glucose (BG) monitoring system (BGMS; referred to here as BGMSA) intended for point-of-care testing using samples from patients in diverse clinical settings by intended point-of-care test operators. Methods: Arterial, capillary, venous, or heel stick whole blood (WB) samples from patients in non-critical and critical care settings were collected and analyzed using BGMSA and the Nova StatStrip ® BGMS (Nova Biomedical, Waltham, MA; referred to here as BGMSB), and a hexokinase comparator (Cobas 6000 Analyzer Series; Roche Diagnostics GmbH). The blood glucose measurement accuracy was assessed by the Food and Drug Administration guidance criteria. Results: Two studies are presented. In the first, 2678 samples (622 arterial, 706 capillary, 1203 venous, 147 heel stick) were collected from 1577 patients in 14 US and three European sites. All accuracy criteria were met for arterial and venous samples considering all data combined. BGMSA showed better accuracy than BGMSB for arterial, venous, and heel stick, and similar results to BGMSB for capillary WB vs venous comparator. No endogenous interference from pO 2 , hematocrit, and sodium was identified. BGMSA was also accurate when analyzing contrived samples used to show accuracy over a wide range of glucose concentrations, alone and when combined with extreme hematocrit. In the second study, 117 capillary fingerstick samples collected at one US site were measured on both BGMSA and the comparator, and all accuracy criteria were met. No clinically significant medical risks were observed via Diabetes Technology Society Error Grids. Conclusions: BGMSA was effective for determining blood glucose in venous, arterial, neonatal arterial, neonatal heel stick, and capillary WB samples.
Prognosis is worse with elevated cardiac troponin in nonacute coronary syndrome compared with acute coronary syndrome
Horiuchi, Yu , Patel, Mitul , Mueller, Christian, Neath, Sean‐Xavier , Christenson, Robert H. , Morgenthaler, Nils G., McCord, James , Nowak, Richard M. , Vilke, Gary M. , Daniels, Lori B. , Apple, Fred S. , Cannon, Chad , Nagurney, John T., Schreiber, Donald , Diercks, Deborah B. , Headden, Gary , Limkakeng, Alexander T. , Wu, Alan H.B. , Ebmeyer, Stefan , Jaffe, Allan S. , Maisel, Alan S. , Daniels, Lori B , Wettersten, Nicholas , Hollander, Judd E. , deFilippi, Christopher R. , Hogan, Christopher , Anand, Inder S. , Jaffe, Allan S. , Peacock, William Frank

Coronary Artery Disease | July 26, 2022 | Volume: 33 | Issue: 5 | Pages: 376-384

10.1097/mca.0000000000001135 Get It

Background Cardiac troponin (cTn) can be elevated in many patients presenting to the emergency department (ED) with chest pain but without a diagnosis of acute coronary syndrome (ACS). We compared the prognostic significance of cTn in these different populations. Methods We retrospectively analyzed the CHOPIN study, which enrolled patients who presented to the ED with chest pain. Patients were grouped as ACS, non-ACS cardiovascular disease, noncardiac chest pain and chest pain not otherwise specified (NOS). We examined the prognostic ability of cTnI for the clinical endpoints of mortality and major adverse cardiovascular event (MACE; a composite of acute myocardial infarction, unstable angina, revascularization, reinfarction, and congestive heart failure and stroke) at 180-day follow-up. Results Among 1982 patients analyzed, 14% had ACS, 21% had non-ACS cardiovascular disease, 31% had a noncardiac diagnosis and 34% had chest pain NOS. cTnI elevation above the 99th percentile was observed in 52, 18, 6 and 7% in these groups, respectively. cTnI elevation was associated with mortality and MACE, and their relationships were more prominent in noncardiac diagnosis and chest pain NOS than in ACS and non-ACS cardiovascular diagnoses for mortality, and in non-ACS patients than in ACS patients for MACE (hazard ratio for doubling of cTnI 1.85, 2.05, 8.26 and 4.14, respectively; P for interaction 0.011 for mortality; 1.04, 1.23, 1.54 and 1.42, respectively; P for interaction <0.001 for MACE). Conclusion In patients presenting to the ED with chest pain, cTnI elevation was associated with a worse prognosis in non-ACS patients than in ACS patients.
Biomarkers Enhance Discrimination and Prognosis of Type 2 Myocardial Infarction
Horiuchi, Yu , Wettersten, Nicholas , Patel, Mitul , Mueller, Christian, Neath, Sean‐Xavier , Christenson, Robert H. , Morgenthaler, Nils G., McCord, James , Nowak, Richard M. , Vilke, Gary M. , Daniels, Lori B. , Apple, Fred S. , Cannon, Chad , Nagurney, John Tobias , Schreiber, Donald , Diercks, Deborah B. , Headden, Gary , Limkakeng, Alexander T. , Wu, Alan H.B. , Ebmeyer, Stefan , Jaffe, Allan S. , Peacock, W. Frank, Maisel, Alan , Müller, Christian , Mueller, Christian , Daniels, Lori B , Hollander, Judd E. , deFilippi, Christopher R. , Hogan, Christopher J. , Anand, Inder S. , Jaffe, Allan S.

Circulation | August 21, 2020 | Volume: 142 | Issue: 16 | Pages: 1532-1544

10.1161/circulationaha.120.046682 Get It

Background: The observed incidence of type 2 myocardial infarction (T2MI) is expected to increase with the implementation of increasingly sensitive cTn assays. However, it remains to be determined how to diagnose, risk-stratify, and treat patients with T2MI. We aimed to discriminate and risk-stratify T2MI using biomarkers. Methods: Patients presenting to the emergency department with chest pain, enrolled in the CHOPIN study (Copeptin Helps in the early detection Of Patients with acute myocardial INfarction), were retrospectively analyzed. Two cardiologists adjudicated type 1 MI (T1MI) and T2MI. The prognostic ability of several biomarkers alone or in combination to discriminate T2MI from T1MI was investigated using receiver operating characteristic curve analysis. The biomarkers analyzed were cTnI, copeptin, MR-proANP (midregional proatrial natriuretic peptide), CT-proET1 (C-terminal proendothelin-1), MR-proADM (midregional proadrenomedullin), and procalcitonin. The prognostic utility of these biomarkers for all-cause mortality and major adverse cardiovascular event (a composite of acute myocardial infarction, unstable angina pectoris, reinfarction, heart failure, and stroke) at 180-day follow-up was also investigated. Results: Among the 2071 patients, T1MI and T2MI were adjudicated in 94 and 176 patients, respectively. Patients with T1MI had higher levels of baseline cTnI, whereas those with T2MI had higher baseline levels of MR-proANP, CT-proET1, MR-proADM, and procalcitonin. The area under the receiver operating characteristic curve for the diagnosis of T2MI was higher for CT-proET1, MR-proADM, and MR-proANP (0.765, 0.750, and 0.733, respectively) than for cTnI (0.631). Combining all biomarkers resulted in a similar accuracy to a model using clinical variables and cTnI (0.854 versus 0.884, P =0.294). Addition of biomarkers to the clinical model yielded the highest area under the receiver operating characteristic curve (0.917). Other biomarkers, but not cTnI, were associated with mortality and major adverse cardiovascular event at 180 days among all patients, with no interaction between the diagnosis of T1MI or T2MI. Conclusions: Assessment of biomarkers reflecting pathophysiologic processes occurring with T2MI might help differentiate it from T1MI. All biomarkers measured, except cTnI, were significant predictors of prognosis, regardless of the type of myocardial infarction.