Multicenter Evaluation of a New Strip-Based Blood Glucose System for Point-of-Care Testing in Critical and Non-Critical Care Settings
Goodman, Michael D. , Bercker, Sven , Breitenbeck, Nancy, Cañada-Vilalta, C., Canepa, Daisy D., Clarke, William , Ganser, Edward O., Geerts, Nienke, Goldsmith, Barbara, Headden, Gary , Hoppensteadt, Debra, Klapperich, Birgit, Matika, Ryan W., Miles, Gabrielle, Mukhopadhyay, Sagori , O’Dell, Rebecca M., Rafique, Zubaid , Schuetzenmeister, Andre, Stankiewicz, Ann F., Swanson, Jonathan R. , Wu, Alan H.B. , Karon, Brad S. , Goodman, Michael , Nichols, James H , Tran, Nam K , Wu, Alan H B , Canepa, Daisy D., Farnsworth, Christopher W , Hoppensteadt, Debra , Nichols, James H. , O’Dell, Rebecca M., Schützenmeister, André , Slingerland, Robbert Jan , Stankiewicz, Ann F.

Journal of Diabetes Science and Technology | May 31, 2025 | Volume: 20 | Issue: 4 | Pages: 1322-1331

10.1177/19322968251325873 Get It

Background: Evaluation of the performance of Cobas ® Pulse (Roche Diagnostics GmbH, Mannheim, Germany), a new blood glucose (BG) monitoring system (BGMS; referred to here as BGMSA) intended for point-of-care testing using samples from patients in diverse clinical settings by intended point-of-care test operators. Methods: Arterial, capillary, venous, or heel stick whole blood (WB) samples from patients in non-critical and critical care settings were collected and analyzed using BGMSA and the Nova StatStrip ® BGMS (Nova Biomedical, Waltham, MA; referred to here as BGMSB), and a hexokinase comparator (Cobas 6000 Analyzer Series; Roche Diagnostics GmbH). The blood glucose measurement accuracy was assessed by the Food and Drug Administration guidance criteria. Results: Two studies are presented. In the first, 2678 samples (622 arterial, 706 capillary, 1203 venous, 147 heel stick) were collected from 1577 patients in 14 US and three European sites. All accuracy criteria were met for arterial and venous samples considering all data combined. BGMSA showed better accuracy than BGMSB for arterial, venous, and heel stick, and similar results to BGMSB for capillary WB vs venous comparator. No endogenous interference from pO 2 , hematocrit, and sodium was identified. BGMSA was also accurate when analyzing contrived samples used to show accuracy over a wide range of glucose concentrations, alone and when combined with extreme hematocrit. In the second study, 117 capillary fingerstick samples collected at one US site were measured on both BGMSA and the comparator, and all accuracy criteria were met. No clinically significant medical risks were observed via Diabetes Technology Society Error Grids. Conclusions: BGMSA was effective for determining blood glucose in venous, arterial, neonatal arterial, neonatal heel stick, and capillary WB samples.
Suppression of Markers of Thrombin Generation and Inflammation in Patients Receiving Low Molecular Weight Heparin Compared to Unfractionated Heparin for TEE-Guided Cardioversion of Atrial Fibrillation.
Fareed, Jawed , Jasper, Susan E., Lieber, Elizabeth, Katz, William E. , Malouf, Joseph F., Stoddard, Marcus F. , Hoppensteadt, Debra , Klein, Allan L. , Apperson-Hansen, Carolyn

Blood | April 18, 2020 | Volume: 110 | Issue: 11 | Pages: 3621-3621

10.1182/blood.v110.11.3621.3621 Get It

Abstract Introduction: Atrial fibrillation (AF) represents a cardiovascular syndrome which can lead to embolic stroke. Several AF clinical trials have shown a decrease risk of stroke with anticoagulation using warfarin. Currently, there are two approaches for anticoagulation in AF patients. For outpatients, warfarin is used with an INR goal 2.0–3.0. For inpatients requiring cardioversion, unfractionated heparin (UFH, IV) is used as a bridge to therapeutic warfarin. More recently, anticoagulation with a low molecular weight heparin, enoxaparin, has been reported to give a more predictable anticoagulant response than UFH in TEEguided cardioversion. The present study compares the markers of inflammation and thrombin generation in patients included in the ACUTE II study. Methods: This was a randomized multicenter trial of 155 patients from 17 clinical sites, the anticoagulant activity of LMWH (enoxaparin, 1 mg/kg sc bid, Sanofi-Aventis, n=76) was compared to that of UFH (APTT 1.5 – 2.5 x control, n=79). Blood samples were drawn at enrollment (baseline), day 2 (peri cardioversion) and day 4 in both groups. Day 2 and day 4 samples were taken 3–4 hours after the injection of LMWH in patients in the LMWH group. Blood samples were evaluated for inflammation: C-reactive protein (CRP), CD 40 ligand (CD 40L), monocyte chemotactic protein 1 (MCP-1) and anticoagulant effect: thrombin antithrombin complex (TAT) and prothrombin fragment (F 1.2). Results: The APTT and anti-Xa levels indicated therapeutic anticoagulation was achieved (previously reported). In addition, both TAT and F1.2 levels were increased at baseline and were significantly decreased with LMWH (p<0.01) in comparison to UFH. The CRP, CD40L, MCP-1 were decreased after treatment in both groups of patients. These results suggest that AF patients treated with LMWH demonstrate a stronger anticoagulant effect as measured by a significant reduction in the markers of thrombin generation. Furthermore, anticoagulation with either UFH of LMWH results in a decrease in inflammation which was not different between groups. Conclusion: In the ACUTE II trial, anticoagulation with LMWH in AF patients may be a better alternate than UFH during TEE-guided cardioversion due to a a stronger anticoagulant.