Abstract Aim To confirm or refute recent pilot studies showing unexpectedly high rates of undetected heart failure (HF) in cardiology patients. Methods We assessed the prevalence, characteristics, and outcome of undetected HF in a large prospective cohort study of patients referred for non-invasive coronary artery disease (CAD) work-up with cardiac positron emission tomography computed tomography. HF presence and phenotype were centrally adjudicated by an independent cardiologist according to clinical practice guidelines requiring three mandatory criteria: symptoms, elevated natriuretic peptides, and structural/functional cardiac abnormalities. The endpoint was a composite of cardiovascular death and acute HF (AHF) hospitalization through 2-year of follow-up. Results Among 1738 eligible patients (median age 67 years, 30% women), 138 patients (7.9%) had known HF, and 534 of 1600 patients (33.4%) without known HF had adjudicated undetected HF, resulting in a ratio of undetected HF to known HF of 3.9 (95%CI, 3.2–4.7)-to-1 and a number needed to screen to detect one patient with undetected HF of 3.0 (95%CI, 2.9-3.1). In undetected HF, left ventricular ejection fraction (LVEF) was preserved in 72.3%, mildly reduced in 16%, and reduced in 11.7%. Older age, known CAD, atrial fibrillation, previous pacemaker implantation, and ECG abnormalities were associated with a higher likelihood for undetected HF. Undetected HF was associated with an increased cumulative incidence of the composite endpoint (adjusted subdistribution hazard ratio 7.37 [95%CI, 3.87-14.06], p<0.001, versus no HF). Conclusion One-out-of three patients referred for CAD work-up had undetected HF, which was associated with cardiovascular death and AHF hospitalization.
Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 Assay
Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
Peri-procedural myocardial infarction/injury after percutaneous coronary intervention
Abstract The coronavirus disease 2019 (COVID-19) pandemic has increased awareness that severe acute respiratory distress syndrome coronavirus-2 (SARS-CoV-2) may have profound effects on the cardiovascular system. COVID-19 often affects patients with pre-existing cardiac disease, and may trigger acute respiratory distress syndrome (ARDS), venous thromboembolism (VTE), acute myocardial infarction (AMI), and acute heart failure (AHF). However, as COVID-19 is primarily a respiratory infectious disease, there remain substantial uncertainty and controversy whether and how cardiovascular biomarkers should be used in patients with suspected COVID-19. To help clinicians understand the possible value as well as the most appropriate interpretation of cardiovascular biomarkers in COVID-19, it is important to highlight that recent findings regarding the prognostic role of cardiovascular biomarkers in patients hospitalized with COVID-19 are similar to those obtained in studies for pneumonia and ARDS in general. Cardiovascular biomarkers reflecting pathophysiological processes involved in COVID-19/pneumonia and its complications have a role evaluating disease severity, cardiac involvement, and risk of death in COVID-19 as well as in pneumonias caused by other pathogens. First, cardiomyocyte injury, as quantified by cardiac troponin concentrations, and haemodynamic cardiac stress, as quantified by natriuretic peptide concentrations, may occur in COVID-19 as in other pneumonias. The level of those biomarkers correlates with disease severity and mortality. Interpretation of cardiac troponin and natriuretic peptide concentrations as quantitative variables may aid in risk stratification in COVID-19/pneumonia and also will ensure that these biomarkers maintain high diagnostic accuracy for AMI and AHF. Second, activated coagulation as quantified by D-dimers seems more prominent in COVID-19 as in other pneumonias. Due to the central role of endothelitis and VTE in COVID-19, serial measurements of D-dimers may help physicians in the selection of patients for VTE imaging and the intensification of the level of anticoagulation from prophylactic to slightly higher or even therapeutic doses.
ESC Study Group on Cardiac Biomarkers of the Association for Acute CardioVascular Care: A fond farewell at the retirement of CKMB
Background: The observed incidence of type 2 myocardial infarction (T2MI) is expected to increase with the implementation of increasingly sensitive cTn assays. However, it remains to be determined how to diagnose, risk-stratify, and treat patients with T2MI. We aimed to discriminate and risk-stratify T2MI using biomarkers. Methods: Patients presenting to the emergency department with chest pain, enrolled in the CHOPIN study (Copeptin Helps in the early detection Of Patients with acute myocardial INfarction), were retrospectively analyzed. Two cardiologists adjudicated type 1 MI (T1MI) and T2MI. The prognostic ability of several biomarkers alone or in combination to discriminate T2MI from T1MI was investigated using receiver operating characteristic curve analysis. The biomarkers analyzed were cTnI, copeptin, MR-proANP (midregional proatrial natriuretic peptide), CT-proET1 (C-terminal proendothelin-1), MR-proADM (midregional proadrenomedullin), and procalcitonin. The prognostic utility of these biomarkers for all-cause mortality and major adverse cardiovascular event (a composite of acute myocardial infarction, unstable angina pectoris, reinfarction, heart failure, and stroke) at 180-day follow-up was also investigated. Results: Among the 2071 patients, T1MI and T2MI were adjudicated in 94 and 176 patients, respectively. Patients with T1MI had higher levels of baseline cTnI, whereas those with T2MI had higher baseline levels of MR-proANP, CT-proET1, MR-proADM, and procalcitonin. The area under the receiver operating characteristic curve for the diagnosis of T2MI was higher for CT-proET1, MR-proADM, and MR-proANP (0.765, 0.750, and 0.733, respectively) than for cTnI (0.631). Combining all biomarkers resulted in a similar accuracy to a model using clinical variables and cTnI (0.854 versus 0.884, P =0.294). Addition of biomarkers to the clinical model yielded the highest area under the receiver operating characteristic curve (0.917). Other biomarkers, but not cTnI, were associated with mortality and major adverse cardiovascular event at 180 days among all patients, with no interaction between the diagnosis of T1MI or T2MI. Conclusions: Assessment of biomarkers reflecting pathophysiologic processes occurring with T2MI might help differentiate it from T1MI. All biomarkers measured, except cTnI, were significant predictors of prognosis, regardless of the type of myocardial infarction.
Will sacubitril-valsartan diminish the clinical utility of B-type natriuretic peptide testing in acute cardiac care?