Abstract Purpose: Gastroenteropancreatic neuroendocrine tumors (GEP-NET) are relatively indolent but can be more aggressive. The current recommendations for using serum chromogranin A (CgA) for patients with GEP-NET are equivocal. This study was designed to validate an automated CgA immunofluorescence assay for monitoring disease progression in patients with GEP-NET. Patients and Methods: A prospective, multicenter, blinded observational study was designed to validate an automated CgA immunofluorescence assay for monitoring disease progression in patients with GEP-NET. Tumor progression was evaluated with RECIST 1.1 by CT/MRI. An increase ≥50% above the prior CgA concentration to a value >100 ng/mL in the following CgA concentration was considered positive. Results: A total of 153 patients with GEP-NET were enrolled. Using the prespecified cut-off of CgA change for tumor progression, specificity was 93.4% (95% confidence interval, 90.4%–95.5%; P < 0.001), sensitivity 34.4% (25.6%–44.3%), positive predictive value 57.9% (45.0–69.8), negative predictive value 84.3% (80.5–87.6), and AUC 0.73 (0.67–0.79). Conclusions: Changes in serial measurements of serum CgA had a favorable specificity and negative predictive value, making this test a useful adjunct to routine radiographic monitoring.
Performance of Three Anti-SARS-CoV-2 Anti-S and One Anti-N Immunoassays for the Monitoring of Immune Status and Vaccine Response
This study aimed to evaluate and compare the performance of three anti-S and one anti-N assays that were available to the project in detecting antibody levels after three commonly used SARS-CoV-2 vaccines (Pfizer, Moderna, and Johnson & Johnson). It also aimed to assess the association of age, sex, race, ethnicity, vaccine timing, and vaccine side effects on antibody levels in a cohort of 827 individuals. In September 2021, 698 vaccinated individuals donated blood samples as part of the Association for Diagnostics & Laboratory Medicine (ADLM) COVID-19 Immunity Study. These individuals also participated in a comprehensive survey covering demographic information, vaccination status, and associated side effects. Additionally, 305 age- and gender-matched samples were obtained from the ADLM 2015 sample bank as pre-COVID-19-negative samples. All these samples underwent antibody level analysis using three anti-S assays, namely Beckman Access SARS-CoV-2 IgG (Beckman assay), Ortho Clinical Diagnostics VITROS Anti-SARS-CoV-2 IgG (Ortho assay), Siemens ADVIA Centaur SARS-CoV-2 IgG (Siemens assay), and one anti-N antibody assay: Bio-Rad Platelia SARS-CoV-2 Total Ab assay (BioRad assay). A total of 827 samples (580 COVID-19 samples and 247 pre-COVID-19 samples) received results for all four assays and underwent further analysis. Beckman, Ortho, and Siemens anti-S assays showed an overall sensitivity of 99.5%, 97.6%, and 96.9%, and specificity of 90%, 100%, and 99.6%, respectively. All three assays indicated 100% sensitivity for individuals who received the Moderna vaccine and boosters, and over 99% sensitivity for the Pfizer vaccine. Sensitivities varied from 70.4% (Siemens), 81.5% (Ortho), and 96.3% (Beckman) for individuals who received the Johnson & Johnson vaccine. BioRad anti-N assays demonstrated 46.2% sensitivity and 99.25% specificity based on results from individuals with self-reported infection. The highest median anti-S antibody levels were measured in individuals who received the Moderna vaccine, followed by Pfizer and then Johnson & Johnson vaccines. Higher anti-S antibody levels were significantly associated with younger age and closer proximity to the last vaccine dose but were not associated with gender, race, or ethnicity. Participants with higher anti-S levels experienced significantly more side effects as well as more severe side effects (e.g., muscle pain, chills, fever, and moderate limitations) (p < 0.05). Anti-N antibody levels only indicated a significant correlation with headache. This study indicated performance variations among different anti-S assays, both among themselves and when analyzing individuals with different SARS-CoV-2 vaccines. Caution should be exercised when conducting large-scale studies to ensure that the same platform and/or assays are used for the most effective interpretation of the data.
Large-Scale Scientific Study Led by a Professional Organization during the COVID-19 Pandemic: Operations, Best Practices, and Lessons Learned
Abstract In 2021, the Association for Diagnostics & Laboratory Medicine (ADLM) (formerly the American Association for Clinical Chemistry [AACC]) developed a scientific study that aimed to contribute to the understanding of SARS-CoV-2 immunity during the evolving course of the pandemic. This study was led by a group of expert member volunteers and resulted in survey data from 975 individuals and blood collection from 698 of those participants. This paper describes the formulation and execution of this large-scale scientific study, encompassing best practices and insights gained throughout the endeavor.
Chromogranin A as surveillance biomarker in patients with carcinoids: CASPAR.
e16242 Background: Gastroenteropancreatic neuroendocrine tumors (GEP-NETs) are rare cancers with highly heterogeneous growth rates, yielding very broad ranges of radiographic imaging intervals in standard guidelines, with a multitude of risk for patients. Better tools are needed to reduce risks for these patients. Chromogranin A (CgA) is released by GEP-NET cells and has been associated with increased tumor burden. The European Neuroendocrine Tumor Society (ENETS) considers CgA to be the most practical and useful general serum tumor marker in patients with NETs. However, clinical utility has been limited by the lack of prospective validation studies and by different sensitivity of CgA according to NET tumor type and volume. Accordingly, expert consensus guidelines have offered varying advice regarding the use of CgA to practicing clinicians. The aim was to evaluate the performance of the B·R·A·H·M·S CgA II KRYPTOR immunoassay to monitor the course of disease in patients with well-differentiated GEP-NETs (grade 1 and grade 2). This is the first prospective validation of a clinical algorithm for the interpretation of CgA values in patients with advanced GEP-NETs. Methods: This prospective, multi-center, observational study was designed to validate the performance of the B·R·A·H·M·S CgA II KRYPTOR assay in monitoring disease progression in a defined population of GEP-NET patients with minimal confounding from end organ dysfunction or concomitant medications (e.g. PPIs). Patients were followed for up to 36 months including the evaluation of tumor burden with RECIST 1.1 categorization by imaging (CT/MRI scans). A clinical cut-off for changes in CgA levels over time to indicate the risk that a tumor progression occurred was derived from a retrospective, bicentric observational pilot study. A change in CgA levels between visits was considered positive, if the CgA concentration increased by more than 50% to an absolute value of >100 ng/ml. Results: A total of 175 adult patients were enrolled, and 153 patients had measurable disease at baseline and ≥1 follow-up visit. Using the cut-off for CgA increase defined above resulted in a sensitivity of 34.4% (95%-CI: 25.6% - 44.3%, p < 0.001) and a specificity of 93.4% (95%-CI: 90.4% – 95.5%, p < 0.001). Positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+) and negative likelihood ratio (LR-) to diagnose whether a tumor progression occurred according RECIST 1.1 criteria were 57.9% (95% CI: 45.0-69.8), 84.3% (95% CI: 80.5-87.6), 5.20 (95% CI: 3.23-8.36), and 0.70 (95% CI: 0.61-0.81), respectively. The AUC was estimated at 0.731 (95% CI: 0.670-0.793). Conclusions: B·R·A·H·M·S CgA II KRYPTOR can be used in conjunction with other clinical methods as an aid in monitoring of disease progression during the course of disease and treatment in patients with gastroentero-pancreatic neuroendocrine tumors (GEP-NETs, grade 1 and grade 2).
T Cell Responses Correlate with Self-Reported Disease Severity and Neutralizing Antibody Responses Predict Protection against SARS-CoV-2 Breakthrough Infection
Objectives: The objective of this prospective study was to investigate the role of adaptive immunity in response to SARS-CoV-2 vaccines. Design and Methods: A cohort of 677 vaccinated individuals participated in a comprehensive survey of their vaccination status and associated side effects, and donated blood to evaluate their adaptive immune responses by neutralizing antibody (NAb) and T cell responses. The cohort then completed a follow-up survey to investigate the occurrence of breakthrough infections. Results: NAb levels were the highest in participants vaccinated with Moderna, followed by Pfizer and Johnson & Johnson. NAb levels decreased with time after vaccination with Pfizer and Johnson & Johnson. T cell responses showed no significant difference among the different vaccines and remained stable up to 10 months after the study period for all vaccine types. In multivariate analyses, NAb responses (<95 U/mL) predicted breakthrough infection, whereas previous infection, the type of vaccine, and T cell responses did not. T cell responses to viral epitopes (<0.120 IU/mL) showed a significant association with the self-reported severity of COVID-19 disease. Conclusion: This study provides evidence that NAb responses to SARS-CoV-2 vaccination correlate with protection against infection, whereas the T cell memory responses may contribute to protection against severe disease but not against infection.
AACC Practical Recommendations for Implementing and Interpreting SARS-CoV-2 Emergency Use Authorization and Laboratory-Developed Test Serologic Testing in Clinical Laboratories
Abstract Background The clinical laboratory continues to play a critical role in managing the coronavirus pandemic. Numerous US Food and Drug Administration emergency use authorization (EUA) and laboratory-developed test (LDT) serologic assays have become available. The performance characteristics of these assays and their clinical utility continue to be defined in real time during this pandemic. The AACC convened a panel of experts from clinical chemistry, microbiology, and immunology laboratories; the in vitro diagnostics industry; and regulatory agencies to provide practical recommendations for implementation and interpretation of these serologic tests in clinical laboratories. Content The currently available EUA serologic tests and platforms, information on assay design, antibody classes including neutralizing antibodies, and the humoral immune responses to SARS-CoV-2 are discussed. Verification and validation of EUA and LDT assays are described, along with a quality management approach. Four indications for serologic testing are outlined. Recommendations for result interpretation, reporting comments, and the role of orthogonal testing are also presented. Summary This document aims to provide a comprehensive reference for laboratory professionals and healthcare workers to appropriately implement SARS-CoV-2 serologic assays in the clinical laboratory and to interpret test results during this pandemic. Given the more frequent occurrence of outbreaks associated with either vector-borne or respiratory pathogens, this document will be a useful resource in planning for similar scenarios in the future.
Screening and Diagnosis of Monoclonal Gammopathies: An International Survey of Laboratory Practice
Context.— Serum tests used for the screening and diagnosis of monoclonal gammopathies include serum protein electrophoresis (SPE; agarose gel or capillary zone), immunofixation (IFE) and immunosubtraction capillary electrophoresis, serum free light chains, quantitative immunoglobulins, and heavy/light–chain combinations. Urine protein electrophoresis and urine IFE may also be used to identify Bence-Jones proteinuria. Objective.— To assess current laboratory practice for monoclonal gammopathy testing. Design.— In April 2016, a voluntary questionnaire was distributed to 923 laboratories participating in a protein electrophoresis proficiency testing survey. Results.— Seven hundred seventy-four laboratories from 38 countries and regions completed the questionnaire (83.9% response rate; 774 of 923). The majority of participants (68.6%; 520 of 758) used agarose gel electrophoresis as their SPE method, whereas 31.4% (238 of 758) used capillary zone electrophoresis. The most common test approaches used in screening were SPE with reflex to IFE/immunosubtraction capillary electrophoresis (39.3%; 299 of 760); SPE only (19.1%; 145 of 760); SPE and IFE or immunosubtraction capillary electrophoresis (13.9%; 106 of 760); and SPE with IFE, serum free light chain, and quantitative immunoglobulins (11.8%; 90 of 760). Only 39.8% (305 of 767) of laboratories offered panel testing for ordering convenience. Although SPE was used by most laboratories in diagnosing new cases of myeloma, when laboratories reported the primary test used to follow patients with monoclonal gammopathy, only 55.7% (403 of 724) chose SPE, with the next most common selections being IFE (18.9%; 137 of 724), serum free light chain (11.7%; 85 of 724), and immunosubtraction capillary electrophoresis (2.1%; 15 of 724). Conclusions.— Ordering and testing practices for the screening and diagnosis of monoclonal gammopathy vary widely across laboratories. Improving utilization management and report content, as well as recognition and development of laboratory-directed testing guidelines, may serve to enhance the clinical value of testing.