Back to Authors

Yip, Paul S. F.

https://orcid.org/0000-0002-7635-7407

Mayo Clinic

University of Toronto

Citations 2

Assessing Analytical Performance and Correct Classification for Cardiac Troponin Deltas Across Diagnostic Pathways Used for Myocardial Infarction
Kavsak, Peter A. , Sharif, Sameer , Demian, Wael L. L., Belley‐Côté, Emilie P. , Blank, David , Knauer, Michael J. , Thorlacius, Laurel , Raizman, Joshua E., Huang, Yun , Beriault, Daniel R. , Fung, Angela W.S. , Yip, Paul S. F. , Clark, L., Abramson, Beth L. , Friedman, Steven , Atkinson, Paul , Suskin, Neville , Scheuermeyer, Frank , Humphries, Karin H. , Mondoux, Shawn , Ainsworth, Craig , Borges, Flávia K. , Worster, Andrew , McRae, Andrew D. , Jaffe, Allan S. , Belley-Cote, Emilie P , Knauer, Michael , Thorlacius, Laurel , Fung, Angela W S , Yip, Paul M , Friedman, Steven M , Suskin, Neville , Ainsworth, Craig , Borges, Flavia , McRae, Andrew , Jaffe, Allan S. , Beriault, Daniel R , Choi, Won-Shik, Taher, Jennifer , Shea, Jennifer L. , McLaren, Jesse T. T. , Chen‐Tournoux, Annabel , Sivilotti, Marco L.A. , Thiruganasambandamoorthy, Venkatesh , Aakre, Kristin M.

Diagnostics | June 30, 2025 | Volume: 15 | Issue: 13 | Pages: 1652

10.3390/diagnostics15131652 Get It

Background: In the emergency setting, many diagnostic pathways incorporate change in high-sensitivity cardiac troponin (hs-cTn) concentrations (i.e., the delta) to classify patients as low-risk (rule-out) or high-risk (rule-in) for possible myocardial infarction (MI). However, the impact of analytical variation on the delta for correct classification is unknown, especially at concentrations below and around the 99th percentile. Our objective was to assess the impact of delta variation for correct risk classification across the European Society of Cardiology (ESC 0/1 h and 0/2 h), the High-STEACS, and the common change criteria (3C) pathways. Methods: A yearlong accuracy study for hs-cTnT was performed where laboratories across Canada tested three patient-based samples (level 1 target value = 6 ng/L, level 2 target value = 9 ng/L, level 3 target value = 12 ng/L) monthly across 41 different analyzers. The assigned low-delta between levels 1 and 2 was 3 ng/L (i.e., 9 − 6 = 3 ng/L) and the assigned high-delta between levels 1 and 3 was 6 ng/L (i.e., 12 − 6 = 6 ng/L). The low- and high-deltas for each analyzer were determined monthly from the measured values, with the difference calculated from the assigned deltas. The obtained deltas were then assessed via the different pathways on correct classification (i.e., percent correct with 95% confidence intervals, CI) and using non-parametric analyses. Results: The median (interquartile range) difference between the measured versus assigned low-delta (n = 436) and high-delta (n = 439) was −1 ng/L (−1 to 0). The correct classification differed among the pathways. The ESC 0/1 h pathway yielded the lowest percentage of correct classification at 35.3% (95% CI: 30.8 to 40.0) for the low-delta and 90.0% (95% CI: 86.8 to 92.6) for the high-delta. The 3C and ESC 0/2 h pathways yielded higher and equivalent estimates on correct classification: 95.2% (95% CI: 92.7 to 97.0) for the low-delta and 98.2% (95% CI: 96.4 to 99.2) for the high-delta. The High-STEACS pathway yielded 99.5% (95% CI: 98.4 to 99.9) of correct classifications for the high-delta but only 36.2% (95% CI: 31.7 to 40.9) for the low-delta. Conclusions: Analytical variation will impact risk classification for MI when using hs-cTn deltas alone per the pathways. The 3C and ESC 0/2 h pathways have <5% misclassification when using deltas for hs-cTnT in this dataset. Additional studies with different hs-cTnI assays at concentrations below and near the 99th percentile are warranted to confirm these findings.
Analytical Unreliability of 25 Hydroxy Vitamin D Measurements in Pre-Term Neonates
Miller, Jessica , Augustin, Roy, Sepiashvili, Lusia, Bro, Eric T., Weishuhn, Karen, Kotsopoulos, Kirsten, Brennan, Joan, Diambomba, Yenge , Higgins, Victoria , Nichols, Matthew , Beriault, Daniel R. , Yip, Paul S. F. , Bro, Eric, Beriault, Daniel R , Yip, Paul M , Singh, Ravinder J. , Kulasingam, Vathany , Taher, Jennifer

The Journal of Applied Laboratory Medicine | July 20, 2023 | Volume: 8 | Issue: 5 | Pages: 856-870

10.1093/jalm/jfad033 Get It

Abstract Background Vitamin D supplementation is common practice for neonates and infants due to limited stores of vitamin D at birth. Although not commonly encountered, vitamin D toxicity can occur due to over-supplementation. However, toxic concentrations are often not included in method validation experiments, and assays often are not validated in the neonatal population. Methods We compared serial 25 hydroxy vitamin D [25(OH)D] measurements in pre-term neonates receiving 25(OH)D supplementation and identified 12 patients wherein concentrations of 25(OH)D were above 50 ng/mL (125 nM) that required additional investigations as the 25(OH)D results did not match the clinical picture. Available samples were compared across 4 immunoassay platforms (LIAISON XL, Roche Cobas e602, Abbott Alinity i, and Siemens Centaur XP) and LC–MS/MS. Results Concentrations of 25(OH)D observed on one individual immunoassay platform (LIAISON XL) fluctuated substantially between subsequent blood draws in select neonates with elevated concentrations. Serum samples from these patients showed variable agreement between LC–MS/MS and other immunoassay platforms. These fluctuations were not explained by the presence of 3-epimer-25(OH)D or 24,25(OH)2D. Conclusions Although we were unable to identify a cause for the variable elevated results, our findings suggest that neonatal 25(OH)D measurements alone should not be used for assessment of nutritional monitoring, and that clinical correlation and other laboratory parameters including ionized calcium should be considered.