Abstract Background Dipeptidyl peptidase 3 (DPP3) is a peptidase released from dying cells. It cleaves proteins in the renin–angiotensin pathway, which can result in hemodynamic instability. At elevated concentrations DPP3 is associated with worse outcomes, particularly in patients with shock. Herein we describe the assay performance of a DPP3 assay (4TEEN4 Pharmaceuticals GmbH) in human plasma. Methods DPP3 concentration was measured using the DPP3 immunoluminometric assay (4TEEN4 Pharmaceuticals GmbH) and the signal was read using a luminometer (Berthold Centro LB963). Analytical performance was established for precision, linearity, accuracy, detection limit, analytical specificity, reference interval, kit lot-to-lot comparison, specimen type, and sample stability. Results Limit of detection was verified at 1.6 ng/mL in EDTA plasma with a coefficient of variation (CV) of <10%. Precision studies revealed a CV ≤ 6% at 28.5 ng/mL and 59.4 ng/mL and comparability with a manufacturer performed assay was demonstrated between 7.7 and 195.2 ng/mL. An upper 97.5% limit of 22 ng/mL without age or sex associations was verified in healthy donors. The assay was not susceptible to interference from lipemia or bilirubin. However, measured DPP3 concentrations increased linearly with increasing hemolysis. DPP3 concentrations are stable in EDTA plasma for up to 24 h and at least 11 months when stored ambient or at −80°C, respectively. Conclusions DPP3 can be measured precisely in EDTA plasma using the immunoluminometric DPP3 assay. Given the potential clinical use of DPP3 in critical care patients, caution should be taken to avoid inducing pre-analytical hemolysis during sample collection.
Short- and Long-Term Biological Variability of Small Dense LDL, HDL3, and Triglyceride-Rich Lipoprotein Cholesterol
Abstract Background Measurement of cholesterol within lipoprotein subfractions may aid in cardiovascular disease prediction. Simple, homogenous enzymatic assays for the direct measurement of lipoprotein subfractions have been developed to measure small dense low-density lipoprotein cholesterol (sdLDL-C), high-density lipoprotein-3 cholesterol (HDL3-C), and triglyceride-rich lipoprotein (TRL-C) cholesterol. The objective of this study was to determine biological variability for sdLDL-C, HDL3-C, and TRL-C in a healthy reference population to facilitate interpretation of these analytes. Methods Serum samples were collected from 24 healthy subjects (n = 14 female/10 male) daily for 3 days while non-fasting, and daily for 5 days, weekly for 4 weeks, and monthly for 6 months after overnight fasting. sdLDL-C, HDL3-C, and TRL-C cholesterol were measured by homogenous enzymatic assays. Sources of variability (between-subject, within-subject, and analytical) were calculated using random-effects regression models. Reference change value (RCV) and index of individuality (II) for each time period were determined from the variance components. Results Analytic variability (daily, weekly, and monthly CVA) was <3% for each analyte. Monthly within-subject variability (CVI) was 17.1% for sdLDL-C, 7.4% for HDL3-C, and 25.7% for TRL-C. Most of the monthly variation was attributed to between-subject variation for all 3 analytes. Overall RCVs for monthly measurements were 18.1 mg/dL for sdLDL-C, 6.1 mg/dL for HDL3-C, and 16.0 mg/dL for TRL-C. IIs were <0.6 for sdLDL-C and HDL3-C, and 0.81 for TRL-C. Conclusions sdLDL-C, HDL3-C, and TRL-C showed moderate within-subject variability, but high between-subject variability, in a healthy reference population. Given the high individuality of each analyte, population-based reference intervals may be inadequate to detect clinically significant changes.