Objective This study investigates a locally low-rank (LLR) denoising algorithm applied to source images from a clinical task-based functional MRI (fMRI) exam before post-processing for improving statistical confidence of task-based activation maps. Methods Task-based motor and language fMRI was obtained in eleven healthy volunteers under an IRB approved protocol. LLR denoising was then applied to raw complex-valued image data before fMRI processing. Activation maps generated from conventional non-denoised (control) data were compared with maps derived from LLR-denoised image data. Four board-certified neuroradiologists completed consensus assessment of activation maps; region-specific and aggregate motor and language consensus thresholds were then compared with nonparametric statistical tests. Additional evaluation included retrospective truncation of exam data without and with LLR denoising; a ROI-based analysis tracked t-statistics and temporal SNR (tSNR) as scan durations decreased. A test-retest assessment was performed; retest data were matched with initial test data and compared for one subject. Results fMRI activation maps generated from LLR-denoised data predominantly exhibited statistically significant ( p = 4.88×10 –4 to p = 0.042; one p = 0.062) increases in consensus t-statistic thresholds for motor and language activation maps. Following data truncation, LLR data showed task-specific increases in t-statistics and tSNR respectively exceeding 20 and 50% compared to control. LLR denoising enabled truncation of exam durations while preserving cluster volumes at fixed thresholds. Test-retest showed variable activation with LLR data thresholded higher in matching initial test data. Conclusion LLR denoising affords robust increases in t-statistics on fMRI activation maps compared to routine processing, and offers potential for reduced scan duration while preserving map quality.
Evaluation of hearing loss in young adults after exposure to 3.0T MRI with standard hearing protection
Standard clinical protocols require hearing protection during magnetic resonance imaging (MRI) for patient safety. This investigation prospectively evaluated the auditory function impact of acoustic noise exposure during a 3.0T MRI in healthy adults. Twenty-nine participants with normal hearing underwent a comprehensive audiologic assessment before and immediately following a clinically indicated head MRI. Appropriate hearing protection with earplugs (and pads) was used per standard of practice. To characterize noise hazards, current sound monitoring tools were used to measure levels of pulse sequences measured. A third audiologic test was performed if a significant threshold shift (STS) was identified at the second test, within 30 days post MRI. Some sequences produced high levels (up to 114.5 dBA; 129 dB peak SPL) that required hearing protection but did not exceed 100% daily noise dose. One participant exhibited an STS in the frequency region most highly associated with noise-induced hearing loss. No participants experienced OSHA-defined STS in either ear. Overall, OAE measures did not show evidence of changes in cochlear function after MRI. In conclusion, hearing threshold shifts associated with hearing loss or OAE level shifts reflecting underlying cochlear damage were not detected in any of the 3.0T MRI study participants who used the current recommended hearing protection.
Left–Right Intensity Asymmetries Vary Depending on Scanner Model for FLAIR and T1 Weighted MRI Images
BackgroundLocalized regions of left–right image intensity asymmetry (LRIA) were incidentally observed on T2‐weighted (T2‐w) and T1‐weighted (T1‐w) diagnostic magnetic resonance imaging (MRI) images. Suspicion of herpes encephalitis resulted in unnecessary follow‐up imaging. A nonbiological imaging artifact that can lead to diagnostic uncertainty was identified.PurposeTo investigate whether systematic LRIA exist for a range of scanner models and to determine if LRIA can introduce diagnostic uncertainty.Study TypeA retrospective study using the Alzheimer's Disease Neuroimaging Initiative (ADNI) data base.SubjectsOne thousand seven hundred fifty‐three (median age: 72, males/females: 878/875) unique participants with longitudinal data were included.Field Strength3T.SequencesT1‐w three‐dimensional inversion‐recovery spoiled gradient‐echo (IR‐SPGR) or magnetization‐prepared rapid gradient‐echo (MP‐RAGE) and T2‐w fluid‐attenuated inversion recovery (FLAIR) long tau fast spin echo inversion recovery (LT‐FSE‐IR). Only General Electric, Philips, and Siemens' product sequences were used.AssessmentLRIA was calculated as the left–right percent difference with respect to the mean intensity from automated anatomical atlas segmented regions. Three neuroradiologists with 37 (**), 32 (**), and 3 (**) years of experience rated the clinical impact of 30 T2‐w three‐dimensional FLAIR exams with LRIA to determine the diagnostic uncertainty. Statistical comparisons between retrospective intensity normalized T1m and original T1‐w images were made.Statistical TestsFor each image type, a linear mixed effects model was fit using LRIA scores from all scanners, regions, and participants as the outcome and age and sex as predictors. Statistical significance was defined as having a P‐value <0.05.ResultsLRIA scores were significantly different from zero on most scanners. All clinicians were uncertain or recommended definite diagnostic follow‐up in 62.5% of cases with LRIA >10%. Individuals with acute brain pathology or focal neurologic deficits are not enrolled in ADNI; therefore, focal signal abnormalities were considered false positives.Data ConclusionLRIA is system specific, systematic, creates diagnostic uncertainty, and impacts IR‐SPGR, MP‐RAGE, and LT‐FSE‐IR product sequences.Level of Evidence: 2Technical Efficacy Stage: 3
Improved Brain MR Imaging from a Compact, Lightweight 3T Scanner with High‐Performance Gradients
BackgroundA low‐cryogen, compact 3T (C3T) MRI scanner with high‐performance gradients capable of simultaneously achieving 80 mT/m gradient amplitude and 700 T/m/second slew rate has been in use to study research patients since March 2016 but has not been implemented in the clinical practice.PurposeTo compare head MRI examinations obtained with the C3T system and a conventional whole‐body 3T (WB3T) scanner in seven parameters across five commonly used brain imaging sequences.Study TypeProspective.SubjectsThirty patients with a clinically indicated head MRI.Sequence 3T; T1 FLAIR, T1 MP‐RAGE, 3D T2 FLAIR, T2 FSE, and DWI.AssessmentAll patients tolerated the scans well. Three board‐certified neuroradiologists scored the comparative quality of C3T and WB3T images in blinded fashion using a five‐point Likert scale in terms of: signal‐to‐noise ratio, lesion conspicuity, motion artifact, gray/white matter contrast, cerebellar folia, susceptibility artifact, and overall quality.Statistical TestLeft‐sided, right‐sided, and two‐sided Wilcoxon signed rank test; Fisher's method. A P value <0.05 was considered statistically significant.ResultsThe C3T system performed better than the WB3T in virtually all comparisons, except for motion artifacts for the T1 FLAIR and T1 MP‐RAGE sequences, where the WB3T system was deemed better. When combining all sequences together, the C3T system outperformed the WB3T system in all image quality parameters evaluated, except for motion artifact (P = 0.13).Data ConclusionThe C3T scanner provided better overall image quality for all sequences, and performed better in all individual categories, except for motion artifact on the T1 FLAIR and T1 MP‐RAGE.Level of Evidence2Technical Efficacy Stage1
Temperature‐corrected proton density fat fraction estimation using chemical shift‐encoded MRI in phantoms
PurposeChemical shift‐encoded MRI (CSE‐MRI) is well‐established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature is known to bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated to correct for the effects of temperature on PDFF estimation through simulations, temperature‐controlled experiments, and a multi‐center, multi‐vendor phantom study.Theory and MethodsA technical solution that assumes and automatically estimates a uniform, global temperature throughout the phantom is proposed. Computer simulations modeled the effect of temperature on PDFF estimation using magnitude‐, complex‐, and hybrid‐based CSE‐MRI methods. Phantom experiments were performed to assess the temperature correction on PDFF estimation at controlled phantom temperatures. To assess the temperature correction method on a larger scale, the proposed method was applied to data acquired as part of a nine‐site multi‐vendor phantom study and compared to temperature‐corrected PDFF estimation using an a priori guess for ambient room temperature.ResultsSimulations and temperature‐controlled experiments show that as temperature deviates further from the assumed temperature, PDFF bias increases. Using the proposed correction method and a reasonable a priori guess for ambient temperature, PDFF bias and variability were reduced using magnitude‐based CSE‐MRI, across MRI systems, field strengths, protocols, and varying phantom temperature. Complex and hybrid methods showed little PDFF bias and variability both before and after correction.ConclusionCorrection for temperature reduces temperature‐related PDFF bias and variability in phantoms across MRI vendors, sites, field strengths, and protocols for magnitude‐based CSE‐MRI, even without a priori information about the temperature.
The effect of spiral trajectory correction on pseudo‐continuous arterial spin labeling with high‐performance gradients on a compact 3T scanner
PurposeTo demonstrate the feasibility of pseudo‐continuous arterial‐spin–labeled (pCASL) imaging with 3D fast‐spin‐echo stack‐of‐spirals on a compact 3T scanner (C3T), to perform trajectory correction for eddy‐current–induced deviations in the spiral readout of pCASL imaging, and to assess the correction effect on perfusion‐related images with high‐performance gradients (80 mT/m, 700T/m/s) of the C3T.MethodsTo track eddy‐current–induced artifacts with Archimedean spiral readout, the spiral readout in pCASL imaging was performed with 5 different peak gradient slew rate (Smax) values ranging from 70 to 500 T/m/s. The trajectory for each Smax was measured using a dynamic field camera and applied in a density‐compensated gridding image reconstruction in addition to the nominal trajectory. The effect of the trajectory correction was assessed with perfusion‐weighted (ΔM) images and proton‐density–weighted images as well as cerebral blood flow (CBF) maps, obtained from 10 healthy volunteers.ResultsBlurring artifact on ΔM images was mitigated by the trajectory correction. CBF values on the left and right calcarine cortices showed no significant difference after correction. Also, the signal‐to‐noise ratio of ΔM images improved, on average, by 7.6% after correction (P < .001). The greatest improvement of 12.1% on ΔM images was achieved with a spiral readout using Smax of 300~400 T/m/s.ConclusionEddy currents can cause spiral trajectory deviation, which leads to deformation of the CBF map even in cases of low value Smax. The trajectory correction for spiral‐readout–based pCASL produces more reliable results for perfusion imaging. These results suggest that pCASL is feasible on C3T with high‐performance gradients.
Phantom validation of quantitative susceptibility and dynamic contrast‐enhanced permeability MR sequences across instruments and sites
BackgroundQuantitative susceptibility mapping (QSM) and dynamic contrast‐enhanced quantitative permeability (DCEQP) on magnetic resonance (MR) have been shown to correlate with neurovascular disease progression as markers of vascular leakage and hemosiderin deposition. Applying these techniques as monitoring biomarkers in clinical trials will be necessary; however, their validation across multiple MR platforms and institutions has not been rigorously verified.PurposeTo validate quantitative measurement of MR biomarkers on multiple instruments at different institutions.Study TypePhantom validation between platforms and institutions.Phantom ModelT1/susceptibility phantom, two‐compartment dynamic flow phantom.Field Strength/Sequence3T/QSM, T1 mapping, dynamic 2D SPGR.AssessmentPhilips Ingenia, Siemens Prisma, and Siemens Skyra at three different institutions were assessed. A QSM phantom with concentrations of gadolinium, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8 ppm was assayed. DCEQP was assessed by measuring a MultiHance bolus as the consistency of the width ratio of the curves at the input and outputs over a range of flow ratios between outputs.Statistical TestsEach biomarker was assessed by measures of accuracy (Pearson correlation), precision (paired t‐test between repeated measurements), and reproducibility (analysis of covariance [ANCOVA] between instruments).ResultsQSM accuracy of r2 > 0.997 on all three platforms was measured. Precision (P = 0.66 Achieva, P = 0.76 Prisma, P = 0.69 Skyra) and reproducibility (P = 0.89) were good. T1 mapping of accuracy was r2 > 0.98. No significant difference between width ratio regression slopes at site 2 (P = 0.669) or site 3 (P = 0.305), and no significant difference between width ratio regression slopes between sites was detected by ANCOVA (P = 0.48).Data ConclusionThe phantom performed as expected and determined that MR measures of QSM and DCEQP are accurate and consistent across repeated measurements and between platforms.Level of Evidence: 1Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2020;51:1192–1199.
Distortion‐free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion‐free high‐resolution diffusion imaging on a compact 3T with high‐performance gradients
BackgroundDistortion‐free, high‐resolution diffusion imaging using DIADEM (Distortion‐free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated.PurposeTo investigate the clinical feasibility of DIADEM‐based high‐resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high‐performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging.Study TypeProspective feasibility study.Phantom/SubjectsDiffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0‐field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging.Field Strength/Sequence3T; the standard single‐shot echo‐planar‐imaging (EPI), multishot DIADEM diffusion, and anatomical (2D‐FSE [fast‐spin‐echo], 2D‐FLAIR [fluid‐attenuated‐inversion‐recovery], and 3D‐MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging.AssessmentThe scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high‐resolution diffusion imaging in healthy control and brain tumor volunteers.Statistical TestBland–Altman analysis.ResultsThe scan time for high in‐plane (0.86 mm2) resolution, distortion‐free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland–Altman plot. The proposed acquisition with a total off‐resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion‐free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries.Data ConclusionThe proposed high‐resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements.Level of Evidence3Technical EfficacyStage 1 J. Magn. Reson. Imaging 2020;51:296–310.
Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction
BackgroundGradient nonlinearity (GNL) leads to biased apparent diffusion coefficients (ADCs) in diffusion‐weighted imaging. A gradient nonlinearity correction (GNLC) method has been developed for whole body systems, but is yet to be tested for the new compact 3T (C3T) scanner, which exhibits more complex GNL due to its asymmetrical design.PurposeTo assess the improvement of ADC quantification with GNLC for the C3T scanner.Study TypePhantom measurements and retrospective analysis of patient data.Phantom/SubjectsA diffusion quality control phantom with vials containing 0–30% polyvinylpyrrolidone in water was used. For in vivo data, 12 patient exams were analyzed (median age, 33).Field Strength/SequenceImaging was performed on the C3T and two commercial 3T scanners. A clinical DWI (repetition time [TR] = 10,000 msec, echo time [TE] = minimum, b = 1000 s/mm2) sequence was used for phantom imaging and 10 patient cases and a clinical DTI (TR = 6000–10,000 msec, TE = minimum, b = 1000 s/mm2) sequence was used for two patient cases.AssessmentThe 0% vial was measured along three orthogonal axes, and at two different temperatures. The ADC for each concentration was compared between the C3T and two whole‐body scanners. Cerebrospinal fluid and white matter ADCs were quantified for each patient and compared to values in literature.Statistical TestsPaired t‐test and two‐way analysis of variance (ANOVA).ResultsFor all PVP concentrations, the corrected ADC was within 2.5% of the reference ADC. On average, the ADC of cerebrospinal fluid and white matter post‐GNLC were within 1% and 6%, respectively, of values reported in the literature and were significantly different from the uncorrected data (P < 0.05).Data ConclusionThis study demonstrated that GNL effects were more severe for the C3T due to the asymmetric gradient design, but our implementation of a GNLC compensated for these effects, resulting in ADC values that are in good agreement with values from the literature.Level of Evidence: 4Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2018;48:1498–1507
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.