Back to Authors

Kodali, Susheel

https://orcid.org/0000-0003-0517-2074

Mayo Clinic

Columbia University Irving Medical Center

Citations 22

One-Year Outcomes of Mitral Valve-in-Valve Using the SAPIEN 3 Transcatheter Heart Valve
Eleid, Mackram F. , Kodali, Susheel , Krishnaswamy, Amar , Morse, Michael A. , Smalling, Richard W. , Reisman, Mark, Mack, Michael J. , Bapat, Vinayak , Leon, Martin B. , Rihal, Charanjit S. , Makkar, Raj , Whisenant, Brian K. , Kapadia, Samir , McCabe, James M , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

JAMA Cardiology | July 29, 2020 | Volume: 5 | Issue: 11 | Pages: 1245

10.1001/jamacardio.2020.2974 Get It

Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Vemulapalli, Sreekanth , Xiang, Qun, Wang, Dee Dee , Eleid, Mackram F. , Sandhu, Gurpreet S. , Salinger, Michael H., Russell, Hyde M., Kodali, Susheel , Dvir, Danny , Russo, Mark J., Fang, Kenith, Coylewright, Megan , Shah, Pinak , Babaliaros, Vasilis , Khan, Jaffar M. , Tommaso, Carl L. , Saucedo, Jorge , Makkar, Rajj, Mack, Michael J. , Holmes, David R. , Leon, Martin B. , Bapat, Vinayak , Thourani, Vinod H. , Rihal, Charanjit S. , O’Neill, William, Feldman, Ted , Douglas, Pamela S. , Eleid, Mackram, Cabalka, Allison K. , Rihal, Charanjit, Wang, Dee Dee , Douglas, Pamela S , Guerrero, Mayra , Greenbaum, Adam B. , George, Isaac , Whisenant, Brian K. , Pershad, Ashish , Shah, Pinak , Kar, Saibal , Makkar, Raj , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | March 6, 2020 | Volume: 13 | Issue: 3 | Pages: No page available

10.1161/circinterventions.119.008425 Get It

Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Wood, David , Krajcer, Zvonimir , Sathananthan, Janarthanan , Strickman, Neil E., Metzger, Chris, Fearon, William F. , Aziz, Mark, Satler, Lowell F. , Waksman, Ron , Eng, Marvin H. , Heimansohn, David, Sampson, Andrew, Coady, Paul , Rodriguez, Roberto , Krishnaswamy, Amar , Lee, Jason T. , Ben‐Dor, Itsik , Moainie, Sina L. , Kodali, Susheel , Yadav, Pradeep , Kozak, Mark, Bacharach, J. Michael, Feldman, Ted , Nanjundappa, Aravinda , Bersin, Robert M., Potluri, Srinivasa , Barker, Colin M. , Bernardo, Nelson L. , Lumsden, Alan B. , Dake, Michael D. , Brown, David L. , Maor, Nathaniel, Nardone, Samuel, Webb, John G. , Investigators, on behalf of the SAFE MANTA Study, Kapadia, Samir , Greenbaum, Adam B. , Szerlip, Molly , Chhatriwalla, Adnan K , O’Neill, Brian Patrick , Guerrero, Mayra , Zhang, Ming , Barleben, Andrew R. , Campbell, John , Cohen, David Jonathan , Lauck, Sandra , O’Neill, William W. , Investigators, on behalf of the SAFE MANTA Study

Circulation: Cardiovascular Interventions | July 12, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007258 Get It

Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
Imaging in patients with severe mitral annular calcification: insights from a multicentre experience using transatrial balloon-expandable valve replacement
Praz, Fabien , Khalique, Omar , Lee, Raymond , Wu, Isaac Y. , Russell, Hyde M., Wang, Dee Dee , Veeragandham, Ramesh, Islam, Ashequl , Deaton, David W., Eudailey, Kyle W. , Akkoc, Deniz, Kantor, Alex , Wang, Catherine , Tang, Diane, Park, Joongheum S, Leung, Diana, Nazif, Tamim , Vahl, Torsten , Kodali, Susheel , Leon, Martin B. , Takayama, Hiroo , Bapat, Vinayak , Borger, Michael A. , Wang, Dee Dee , Praz, Fabien , Guerrero, Mayra , Kaneko, Tsuyoshi , Tang, Diane C H, Hahn, Rebecca T , George, Isaac , Takayama, Hiroo

European Heart Journal - Cardiovascular Imaging | March 6, 2019 | Volume: 20 | Issue: 12 | Pages: 1395-1406

10.1093/ehjci/jez050 Get It

Abstract Aims To investigate valve sizing and the haemodynamic relevance of the predicted left ventricular outflow tract (LVOT) in patients with mitral annular calcification (MAC) undergoing transatrial transcatheter valve implantation (THV). Methods and results In total, 21 patients undergoing transatrial THV, multiplanar reconstruction (MPR), maximum intensity projection (MIP), and cubic spline interpolation (CSI) were compared for MA sizing during diastole. In addition, predicted neo-LVOT areas were measured in 18 patients and correlated with the post-procedural haemodynamic dimensions. The procedure was successful in all patients (100%). Concomitant aortic valve replacement was performed in eight patients (43%) (AVR group). Sizing using MPR and MIP yielded comparable results in terms of area, perimeter, and diameter, whereas the dimensions obtained with CSI were systematically smaller. The simulated mean systolic neo-LVOT area was 133.4 ± 64.2 mm2 with an anticipated relative LVOT area reduction (neo-LVOT area/LVOT area × 100) of 59.3 ± 14.7%. The systolic relative LVOT area reduction, but not the absolute neo-LVOT area, was found to predict the peak (r = 0.69; P = 0.002) and mean (r = 0.65; P = 0.004) post-operative aortic gradient in the overall population as well as separately in the AVR (peak: r = 0.91; P = 0.002/mean: r = 0.85; P = 0.002) and no-AVR (peak: r = 0.89; P = 0.003/mean: r = 0.72; P = 0.008) groups. Conclusion In patients with severe MAC undergoing transatrial transcatheter valve implantation, MPR, and MIP yielded comparable annular dimensions, while values obtained with CSI tended to be systematically smaller. Mitral annular area and the average annular diameter appear to be reliable parameters for valve selection. Simulated relative LVOT reduction was found to predict the post-procedural aortic gradients.
4994Transcatheter versus surgical aortic valve replacement in patients with prior cardiac surgery in the randomized PARTNER 2A Trial
Chen, S, Redfors, Björn , Ben‐Yehuda, Ori , Crowley, Aaron , Greason, Kevin L. , Finn, Matthew , Vahl, Torsten , Thourani, Vinod H. , Suri, Rakesh M. , Svensson, Lars G. , Webb, John G. , Kodali, Susheel , Leon, M.B., Investigators, the PARTNER 2 Trial, Alu, Maria C. , Nazif, Tamim , Investigators, the PARTNER 2 Trial

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy566.4994 Get It

One-Year Clinical Outcomes With SAPIEN 3 Transcatheter Aortic Valve Replacement in High-Risk and Inoperable Patients With Severe Aortic Stenosis
Thourani, Vinod H. , Kodali, Susheel , Makkar, Raj , Szeto, Wilson Y. , Anwaruddin, Saif , Lim, Scott, Kereiakes, Dean J. , Ramee, Steven, Greason, Kevin L. , Kapadia, Samir , Babaliaros, Vasilis , Pîbarot, Philippe , Weissman, Neil J., Leipsic, Jonathon , Webb, John G. , Mack, Michael J. , Leon, Martin B. , Douglas, Pamela S. , Makkar, Raj R., Desai, Nimesh, Whisenant, Brian K, Herrmann, Howard C. , Desai, Nimesh D. , Malaisrie, S. Chris , Hahn, Rebecca T , Pibarot, Phillippe , Whisenant, Brian K. , Douglas, Pamela S

Circulation | July 12, 2016 | Volume: 134 | Issue: 2 | Pages: 130-140

10.1161/circulationaha.116.022797 Get It

Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P <0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P <0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov . Unique identifier: NCT01314313.
Sex-Specific Differences at Presentation and Outcomes Among Patients Undergoing Transcatheter Aortic Valve Replacement
Kodali, Susheel , Williams, Mathew , Doshi, Darshan , Hahn, Rebecca T. , Humphries, Karin H. , Douglas, Pamela S. , Mack, Michael J. , Xu, Ke , Svensson, Lars G. , Thourani, Vinod H. , Tuzcu, E. Murat , Weissman, Neil J., Leon, Martin B. , Kirtane, Ajay J. , Hahn, Rebecca T , Nkomo, Vuyisile T. , Cohen, David Jonathan , Douglas, Pamela S , Williams, Mathew

Annals of Internal Medicine | February 22, 2016 | Volume: 164 | Issue: 6 | Pages: 377

10.7326/m15-0121 Get It

Risk stratification in patients with pulmonary hypertension undergoing transcatheter aortic valve replacement
Lindman, Brian R. , Zajarías, Alan , Maniar, Hersh S., Miller, D. Craig , Suri, Rakesh M. , Webb, John G. , Svensson, Lars G. , Kodali, Susheel , Xu, Ke , Ayele, Girma , Lin, Fay Y. , Wong, Shing–Chiu, Babaliaros, Vasilis , Thourani, Vinod H. , Douglas, Pamela S. , Lim, Scott, Leon, Martin B. , Mack, Michael J. , Arnold, Suzanne V. , Douglas, Pamela S , Lindman, Brian R

Heart | August 11, 2015 | Volume: 101 | Issue: 20 | Pages: 1656-1664

10.1136/heartjnl-2015-308001 Get It

Objective Pulmonary hypertension (PH) is associated with increased mortality after surgical or transcatheter aortic valve replacement (TAVR) for aortic stenosis (AS), and when the pulmonary artery pressure is particularly elevated, there may be questions about the clinical benefit of TAVR. We aimed to identify clinical and haemodynamic factors associated with increased mortality after TAVR among those with moderate/severe PH. Methods Among patients with symptomatic AS at high or prohibitive surgical risk receiving TAVR in the Placement of Aortic Transcatheter Valves (PARTNER) I randomised trial or registry, 2180 patients with an invasive measurement of mean pulmonary artery pressure (mPAP) recorded were included, and moderate/severe PH was defined as an mPAP ≥35 mm Hg. Results Increasing severity of PH was associated with progressively worse 1-year all-cause mortality: none (n=785, 18.6%), mild (n=838, 22.7%) and moderate/severe (n=557, 25.0%) (p=0.01). The increased hazard of mortality associated with moderate/severe PH was observed in females, but not males (interaction p=0.03). In adjusted analyses, females with moderate/severe PH had an increased hazard of death at 1 year compared with females without PH (adjusted HR 2.14, 95% CI 1.44 to 3.18), whereas those with mild PH did not. Among males, there was no increased hazard of death associated with any severity of PH. In a multivariable Cox model of patients with moderate/severe PH, oxygen-dependent lung disease, inability to perform a 6 min walk, impaired renal function and lower aortic valve mean gradient were independently associated with increased 1-year mortality (p<0.05 for all), whereas several haemodynamic indices were not. A risk score, including these factors, was able to identify patients with a 15% vs 59% 1-year mortality. Conclusions The relationship between moderate/severe PH and increased mortality after TAVR is altered by sex, and clinical factors appear to be more influential in stratifying risk than haemodynamic indices. These findings may have implications for the evaluation of and treatment decisions for patients referred for TAVR with significant PH. Trial registration NCT00530894.
Propensity-Matched Comparisons of Clinical Outcomes After Transapical or Transfemoral Transcatheter Aortic Valve Replacement
Suri, Rakesh M. , Rajeswaran, Jeevanantham , Babaliaros, Vasilis , Douglas, Pamela S. , Fearon, William F. , Miller, D. Craig , Kirtane, Ajay J. , Kodali, Susheel , Mack, Michael J. , Szeto, Wilson Y. , Thourani, Vinod H. , Tuzcu, E. Murat , Williams, Mathew , Akin, Jodi J., Leon, Martin B. , Svensson, Lars G. , Blackstone, Eugene H. , Mack, Michael, Williams, Mathew R, Hahn, Rebecca T , Kapadia, Samir , Douglas, Pamela S , Williams, Mathew

Circulation | April 2, 2015 | Volume: 131 | Issue: 22 | Pages: 1989-2000

10.1161/circulationaha.114.012525 Get It

Background— The higher risk of adverse outcomes after transapical (TA) versus transfemoral (TF) transcatheter aortic valve replacement (TAVR) could be attributable to TA-TAVR being an open surgical procedure or to clinical differences between TA- and TF-TAVR patients. We compared outcomes after neutralizing patient differences using propensity score matching. Methods and Results— From April 2007 to February 2012, 1100 Placement of Aortic Transcatheter Valves (PARTNER)-I patients underwent TA-TAVR and 1521 underwent TF-TAVR with Edwards SAPIEN balloon-expandable bioprostheses. Propensity matching based on 111 preprocedural variables, exclusive of femoral access morphology, identified 501 well-matched patient pairs (46% of possible matches), 95% of whom had peripheral arterial disease. Matched TA-TAVR patients experienced more adverse procedural events, longer length of stay (5 versus 8 days; P <0.0001), and slower recovery (New York Heart Association class I, 31% versus 38% at 30 days, equalizing by 6 months at 51% versus 47%); stroke risk was similar (3.4% versus 3.3% at 30 days and 6.0% versus 6.7% at 3 years); mortality was elevated for the first 6 postprocedural months (19% versus 12%; P =0.01); but aortic regurgitation was less (34% versus 52% mild and 8.9% versus 12% moderate to severe at discharge, P =0.001; 36% versus 50% mild and 10% versus 15% moderate to severe at 6 months, P <0.0001). Conclusions— The likelihood of adverse periprocedural events and prolonged recovery is greater after TA-TAVR than TF-TAVR in vasculopathic patients after accounting for differences in cardiovascular risk factors, although stroke risk is equivalent and aortic regurgitation is less. As smaller delivery systems permit TF-TAVR in many of these patients, we recommend a TF-first access strategy for TAVR when anatomically feasible. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.