Back to Authors

Moses, Jeffrey W.

https://orcid.org/0000-0002-8842-7919

Mayo Clinic

Columbia University Irving Medical Center

Citations 7

Symptom assessment and angina classification of patients with ischemia and nonobstructive coronary arteries undergoing invasive coronary function testing: from the DISCOVER INOCA multicenter registry
Shah, Sachin , Tremmel, Jennifer A., Henry, Timothy D. , Smilowitz, Nathaniel R. , Prasad, Megha , Kobayashi, Yuhei , Henry, Glen, Samady, Habib , Samuels, B, Moses, Jeffrey W. , Zhang, Zhenyu, Tremmel, Jennifer A. , Henry, Glen A., Lerman, Amir , Tı̂rziu, Daniela , Chamié, Daniel , Lansky, Alexandra J.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.1617 Get It

Abstract Background Patients with ischemia and nonobstructive coronary arteries (INOCA) suffer from a broad range of anginal symptoms that may differ depending on the biologic sex of the patient, the underlying coronary vasomotor disorder, or the type of presentation. Purpose We sought to characterize the symptom description and angina classification of patients referred for invasive coronary function testing (CFT) in the DISCOVER INOCA multicenter registry, stratified by type of presentation (stable vs unstable), biologic sex, and underlying diagnosis, including coronary microvascular dysfunction (CMD), vasospastic angina (VSA), or other disorders such as symptomatic myocardial bridging. Methods DISCOVER INOCA is a prospective, multicenter registry in the United States that includes patients who are referred for clinically indicated coronary angiography and found to have INOCA. All patients underwent protocol-guided angiography, acetylcholine provocation, coronary thermodilution, and intravascular imaging. Symptom characteristics were compared between groups. Results From September 2022 until February 2024, 104 patients were enrolled, 78% were female, and mean age was 57 ± 11 years. The post-procedure diagnosis was CMD in 19%, VSA in 41%, a mixed syndrome in 15%, or other diagnosis in 26%. The average coronary flow reserve (CFR) was 2.9 ± 1.1 in the CMD group and 5.3 ± 3.0 in the VSA group, (p < 0.001). 53% of patients presented with stable angina and 47% with unstable or progressive symptoms. Symptoms included chest pain (89%), chest tightness (42%), chest pressure (39%), shortness of breath (53%), and fatigue (16%), and no significant differences were reported when stratified by diagnostic phenotype. Female patients were more likely to report arm/neck/back/jaw pain (25% vs 5% in men, p = 0.038). Symptom triggers included exertion/activity in 73%, emotional stress in 12%, and resting symptoms in 58%. In female patients 4% reported catamenial symptoms. Of patients with stable angina, the Canadian Cardiovascular Society (CCS) Angina Classification was Grade I in 25%, Grade II in 52%, Grade III in 21%, and Grade IV in 2%. In patients with unstable angina, the Braunwald Angina Classification was Class I in 9%, Class II in 73%, and Class III in 18%. Conclusions Patients with INOCA referred for clinically indicated coronary angiography and CFT were predominantly female and most commonly reported chest pain as a presenting symptom. Female patients were more likely to report arm/neck/back/jaw pain than male patients. Over half of patients reported resting symptoms with no differences between the diagnostic phenotypes (CMD, VSA, or other). The CCS and Braunwald angina classification indicated that most patients had moderate intensity symptoms. Patient-reported outcome measures will be used to systematically categorize the symptom burden in these patients.
Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents
O’Malley, A. James , Moses, Jeffrey W. , Leon, Martin B. , Holmes, David R. , Teirstein, Paul S., Schofer, Joachim, Breithardt, Günter, Cutlip, Donald E. , Kereiakes, Dean J. , Shi, Chunxue , Firth, Brian G., Donohoe, Dennis, Kuntz, Richard E., Mauri, Laura , Orav, E. John

Circulation | January 18, 2005 | Volume: 111 | Issue: 3 | Pages: 321-327

10.1161/01.cir.0000153356.72810.97 Get It

Background— Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. Methods and Results— Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17±0.45 mm (sirolimus) versus 1.00±0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665). Conclusions— Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.
Quantitative Assessment of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Native Coronary Arteries
Popma, Jeffrey J. , Leon, Martin B. , Moses, Jeffrey W. , Holmes, David R. , Cox, Nicholas , Fitzpatrick, Michelle, Douglas, John S., Lambert, Charles, Mooney, Michael, Yakubov, Steven, Kuntz, Richard E.

Circulation | December 21, 2004 | Volume: 110 | Issue: 25 | Pages: 3773-3780

10.1161/01.cir.0000150331.14687.4b Get It

Background— Sirolimus-eluting stents (SESs) reduce angiographic restenosis in patients with focal, native coronary artery stenoses. This study evaluated the usefulness of SESs in complex native-vessel lesions at high risk for restenosis. Methods and Results— Angiographic follow-up at 240 days was obtained in 701 patients with long (15- to 25-mm) lesions in small-diameter (2.5- to 3.5-mm) native vessels who were randomly assigned to treatment with SESs or bare-metal stents (BMSs) in the SIRIUS trial. Quantitative angiographic measurements of minimal lumen diameter and percent diameter stenosis were obtained within the treated segment, within the stent, and within its 5-mm proximal and distal edges. Patients treated with SESs had lower rates of binary (>50% diameter stenosis) angiographic restenosis within the segment (8.9% versus 36.3% with the BMS; P <0.001) and within the stent (3.2% versus 35.4% with the BMS; P <0.001). SESs were associated with significantly less late lumen loss within the treated segment, within the stent, and within its 5-mm proximal and distal edges (all P <0.001). The reduction of restenosis with the SES was consistent in patients at risk for restenosis, including those with small vessels, long lesions, and diabetes mellitus. The frequency of late aneurysms was similar in the 2 groups. Conclusions— Compared with BMSs, SESs reduced angiographic late lumen loss within the stent and its adjacent 5-mm margins in patients with complex native-vessel lesions.
Treatment of Left Anterior Descending Coronary Artery Disease With Sirolimus-Eluting Stents
Sawhney, Neil, Moses, Jeffrey W. , Leon, Martin B. , Kuntz, Richard E., Popma, Jeffrey J. , Bachinsky, William , Bass, Theodore A., DeMaio, Samuel J., Fry, Edward T.A., Holmes, David R. , Teirstein, Paul S.

Circulation | July 13, 2004 | Volume: 110 | Issue: 4 | Pages: 374-379

10.1161/01.cir.0000136580.34604.b8 Get It

Background— Revascularization strategies often hinge on the presence and degree of left anterior descending coronary artery (LAD) stenosis. A decision for bypass surgery is often based on the durability of surgical LAD revascularization compared with percutaneous approaches. By decreasing restenosis, drug-eluting stents may have reduced the “reintervention gap” between surgery and percutaneous intervention, making the percutaneous route preferable. Methods and Results— Of the 1101 patients in the SIRIUS trial, 459 with an LAD stenosis were randomized to percutaneous intervention with either sirolimus-eluting or bare-metal stents. Baseline demographic, clinical, and angiographic data were obtained. Patients had 1-year clinical and 8-month angiographic follow-up. Baseline characteristics were similar in both groups. The majority of lesions were tubular type B lesions (69.7%) with a mean diameter of 2.73 mm and a mean length of 14.0 mm. The binary in-stent restenosis rate was 2% for the sirolimus stent group and 41.6% for the bare-metal arm (relative risk, 0.05; 95% CI, 0.02 to 0.1; P <0.001). One-year major adverse events (defined as cardiac death, Q-wave and non–Q-wave myocardial infarction, or target vessel revascularization) was decreased 59% in the sirolimus-stent group (9.8% versus 24.9%; relative risk, 0.39; 95% CI, 0.26 to 0.61; P <0.001). Subgroup analysis of 135 patients with proximal LAD lesions showed similar benefits. In-stent restenosis was 0 in the proximal LAD sirolimus-eluting group (n=67), compared with 38% in the bare-metal arm (n=68), and major adverse events demonstrated a similar trend, with a 50% decrease compared with control patients (10.4% versus 20.6%, P =NS). Conclusions— Sirolimus-eluting stents significantly decrease revascularization rates in LAD lesions. At 1 year, sirolimus-eluting stent revascularization rates are comparable to historic single vessel bypass surgery revascularization rates.
Randomized Study to Evaluate Sirolimus-Eluting Stents Implanted at Coronary Bifurcation Lesions
Moses, Jeffrey W. , Morice, Marie Claude, Ludwig, Josef, Holmes, David R. , Spanos, Vassilis, Louvard, Yves, Desmedt, Benny, Mario, Carlo Di , Leon, Martin B. , Colombo, Antonio , Di Mario, Carlo

Circulation | February 24, 2004 | Volume: 109 | Issue: 10 | Pages: 1244-1249

10.1161/01.cir.0000118474.71662.e3 Get It

Background— A sirolimus-eluting stent (Cypher, Cordis Corp) has been reported to markedly decrease restenosis in selected lesions; higher-risk lesions, including coronary bifurcations, have not been studied. Methods and Results— This prospective study evaluated the safety and efficacy of sirolimus-eluting stents for treatment of coronary bifurcation lesions. Patients were randomly assigned to either stenting of both branches (group A) or stenting of the main branch with provisional stenting of the side branch (SB) (group B). Eighty-five patients (86 lesions) were enrolled. There was 1 case of unsuccessful delivery of any device at the bifurcation site. Given the high crossover, more lesions were treated with 2 stents (n=63) than with stent/balloon (n=22). Clinical follow-up at 6 months was completed in all patients and angiographic follow-up in 53 patients in group A (85.5%) and 21 in group B (95.4%). One patient died suddenly 4.5 months after the procedure. There were 3 cases of stent thrombosis (3.5%). The total restenosis rate at 6 months was 25.7%, and it was not significantly different between the double-stenting (28.0%) and the provisional SB-stenting (18.7%) groups. Fourteen of the restenosis cases occurred at the ostium of the SB and were focal. Target lesion revascularization was performed in 7 cases; target vessel failure occurred in 15 cases (17.6%). Conclusions— These results are an improvement compared with historical controls using bare metal stents. Restenosis at the SB remains a problem. At this time, no statement can be made regarding the most appropriate technique to use when treating bifurcations with the Cypher stent.
Long-Term Outcome of Patients Treated With Repeat Percutaneous Coronary Intervention After Failure of γ-Brachytherapy for the Treatment of In-Stent Restenosis
Prpic, Ross, Teirstein, Paul S., Moses, Jeffrey W. , Tripuraneni, Prabhakar, Giorgianni, Joseph-Anthony, Jani, Shirish, Wong, S. Chiu, Fish, R. David, Ellis, Stephen G. , Holmes, David R. , Kereiakas, Dean, Kuntz, Richard E., Leon, Martin B. , Reilly, John P. , Lansky, Alexandra J. , Giorgianni, Joseph

Circulation | October 28, 2002 | Volume: 106 | Issue: 18 | Pages: 2340-2345

10.1161/01.cir.0000036366.62288.74 Get It

Background— Although 192 Ir intracoronary brachytherapy has been demonstrated to dramatically reduce the recurrence of in-stent restenosis, up to 24% of these patients will still require repeat target-vessel revascularization. The short- and long-term outcomes of repeat percutaneous intervention in this population have not been characterized. Methods and Results— Analysis was performed of all patients enrolled in the GAMMA-I and GAMMA-II brachytherapy trials who underwent repeat percutaneous target lesion revascularization (TLR) because of restenosis. Subjects were divided into 2 cohorts: those who had received 192 Ir brachytherapy and those randomized to placebo. Forty-five (17.6%) of a total of 256 patients whose index treatment was intracoronary radiation therapy and 36 (29.8%) of 121 patients whose index treatment was placebo required repeat percutaneous TLR. The mean time to this first TLR was 295±206 days in the irradiated group and 202±167 days in the placebo group ( P =0.03). Acute procedural success occurred in 100% of irradiated patients and 94% of placebo controls ( P =0.19). After the first TLR, a subsequent TLR was required in 15 (33.3%) of 45 brachytherapy patients versus 17 (47.2%) of 36 placebo failure patients ( P =0.26). There was no significant difference in time to second TLR between the 2 groups. Other long-term major adverse event rates in both groups were comparable to those of other contemporary angioplasty/stenting series. Conclusions— In those patients who “fail” 192 Ir intracoronary brachytherapy for in-stent restenosis, treatment with 192 Ir delays the time to first TLR. Additionally, repeat percutaneous intervention in these patients is safe and efficacious in the short term, with acceptable long-term results.