Objectives: To longitudinally measure LV diastolic function in HIV-exposed but uninfected (HEU) children perinatally exposed to ART. Design: HEU children who were perinatally exposed to antiretroviral therapy (ART) may be at risk for adverse cardiac effects. We have previously reported that those children have decreased left ventricular (LV) mass, dimension, and septal thickness with increased contractility. Methods: Serial echocardiograms were obtained at specific times from birth to 48 months from two groups of HIV-uninfected children: 148 HIV-negative children who were perinatally exposed to ART and 130 non-ART-exposed HIV-unexposed healthy controls. The following LV diastolic indices were obtained: mitral valve early and late diastolic velocity (E and A), tissue Doppler-derived LV-free wall and septal early diastolic velocity (LV e′ and sep e′). Results: All echocardiographic indices were significantly different in ART-exposed children compared with ART-unexposed healthy controls. Both E and A were overall lower at all ages by 8.28 cm/s (P = 0.0002) and 13.46 cm/s (P < 0.0001) respectively. E/A ratio was higher by 0.27, 0.46, and 0.28 units at birth, 1 year and 2 years of age, respectively (all P ≤ 0.01). Moreover, LV e′ and sep e′ were overall lower at all ages by 0.84 cm/s (P = 0.01) and 0.47 cm/s (P = 0.02), respectively. Conclusion: Children who were exposed to ART in utero have subclinical yet significant differences in specific LV diastolic indices. Follow-up with serial echocardiograms are recommended in this population to further assess the potential cardiac toxicity of perinatal exposure to ART.
Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents
Background— Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. Methods and Results— Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17±0.45 mm (sirolimus) versus 1.00±0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665). Conclusions— Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.