Back to Authors

O’Malley, A. James

https://orcid.org/0000-0001-8389-6217

Mayo Clinic

Dartmouth Institute for Health Policy and Clinical Practice

Citations 2

Financial Integration’s Impact On Care Delivery And Payment Reforms: A Survey Of Hospitals And Physician Practices
Fisher, Elliott S. , O’Malley, A. James , Fraze, Taressa , Colla, Carrie H. , Rodríguez, Hector P. , Lewis, Valerie A. , Woloshin, Steven , Shah, Nilay D. , Meara, Ellen , Shah, Nilay , Shortell, Stephen M. , Wood, Andrew, Palm, Marisha E. , Rosenthal, Meredith B.

Health Affairs | August 3, 2020 | Volume: 39 | Issue: 8 | Pages: 1302-1311

10.1377/hlthaff.2019.01813 Get It

Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents
O’Malley, A. James , Moses, Jeffrey W. , Leon, Martin B. , Holmes, David R. , Teirstein, Paul S., Schofer, Joachim, Breithardt, Günter, Cutlip, Donald E. , Kereiakes, Dean J. , Shi, Chunxue , Firth, Brian G., Donohoe, Dennis, Kuntz, Richard E., Mauri, Laura , Orav, E. John

Circulation | January 18, 2005 | Volume: 111 | Issue: 3 | Pages: 321-327

10.1161/01.cir.0000153356.72810.97 Get It

Background— Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. Methods and Results— Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17±0.45 mm (sirolimus) versus 1.00±0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665). Conclusions— Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.