Background— Restenosis after implantation of coronary artery stents remains a significant clinical problem. We undertook a randomized, double-blind, placebo-controlled trial to determine whether cilostazol, a drug that suppresses intimal proliferation, would reduce renarrowing in patients after stent implantation in native coronary arteries. Methods and Results— We assigned 705 patients who had successful coronary stent implantation to receive, in addition to aspirin, cilostazol 100 mg BID or placebo for 6 months; clopidogrel 75 mg daily was administered to all patients for 30 days. Restenosis was determined by quantitative coronary angiography at 6 months. The minimal luminal diameter at 6 months for cilostazol-treated patients was 1.77 mm for the analysis segment (stent plus 5-mm borders) compared with 1.62 mm in the placebo group ( P =0.01). Restenosis, defined as ≥50% narrowing, occurred in 22.0% of patients in the cilostazol group and in 34.5% of the placebo group ( P =0.002), a 36% relative risk reduction. Restenosis was significantly lower in cilostazol-treated diabetics (17.7% versus 37.7%, P =0.01) and in those with small vessels (23.6% versus 35.2%, P =0.02), long lesions (29.9% versus 46.6%, P =0.04), and left anterior descending coronary artery site (19.3% versus 39.8%, P =0.001). There was no difference in bleeding, rehospitalization, target-vessel revascularization, myocardial infarction, or death. Conclusions— Treatment with the drug cilostazol resulted in a significantly larger minimal luminal diameter and a significantly lower binary restenosis rate compared with placebo-treated patients. These favorable effects were apparent in patients at high risk for restenosis.
Quantitative Assessment of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Native Coronary Arteries
Background— Sirolimus-eluting stents (SESs) reduce angiographic restenosis in patients with focal, native coronary artery stenoses. This study evaluated the usefulness of SESs in complex native-vessel lesions at high risk for restenosis. Methods and Results— Angiographic follow-up at 240 days was obtained in 701 patients with long (15- to 25-mm) lesions in small-diameter (2.5- to 3.5-mm) native vessels who were randomly assigned to treatment with SESs or bare-metal stents (BMSs) in the SIRIUS trial. Quantitative angiographic measurements of minimal lumen diameter and percent diameter stenosis were obtained within the treated segment, within the stent, and within its 5-mm proximal and distal edges. Patients treated with SESs had lower rates of binary (>50% diameter stenosis) angiographic restenosis within the segment (8.9% versus 36.3% with the BMS; P <0.001) and within the stent (3.2% versus 35.4% with the BMS; P <0.001). SESs were associated with significantly less late lumen loss within the treated segment, within the stent, and within its 5-mm proximal and distal edges (all P <0.001). The reduction of restenosis with the SES was consistent in patients at risk for restenosis, including those with small vessels, long lesions, and diabetes mellitus. The frequency of late aneurysms was similar in the 2 groups. Conclusions— Compared with BMSs, SESs reduced angiographic late lumen loss within the stent and its adjacent 5-mm margins in patients with complex native-vessel lesions.