Back to Authors

Than, Martin

https://orcid.org/0000-0001-9399-5227

Mayo Clinic

Christchurch Hospital

Citations 13

Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomized trial
Than, Martin , Pickering, John W. , Buchan, Vanessa A, Florkowski, Christopher M , Mills, Nicholas L. , Hamill, Laura , Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika L., Kavsak, Peter, Jaffe, Allan S. , Apple, Fred S. , Cullen, L, Aldous, Sally, Frampton, Christopher MA, Body, Richard, Lord, Sarah Jane, George, Peter Myles, Devlin, Gerard, Kavsak, Peter A. , Mills, Nicholas L , Than, Martin , Pickering, John W , Joyce, Laura R, Buchan, Vanessa, Florkowski, Christopher M , Hamill, Laura, Prystowsky, Jason, Harger, Simon, Reed, Mary, Bayless, Jared, Feberwee, Alexander, Attenburrow, Tamsin, Norman, Timothy, Welfare, Oliver, Heiden, Tamika, Kavsak, Peter , Jaffe, Allan S. , Apple, Fred S. , Peacock, William Frank , Cullen, Louise , Aldous, Sally, Richards, Arthur M , Lacey, Cameron, Troughton, Richard W , Frampton, Christopher, Body, Rick , Mueller, Christian , Lord, Sarah, George, Peter M, Devlin, Gerard

No container title available | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.21.26351433 Get It

ABSTRACT BACKGROUND Point-of-care (POC) high-sensitivity cardiac troponin (hs-cTn) testing has the potential to expedite decision-making and reduce emergency department (ED) length of stay for patients presenting with possible myocardial infarction (MI) by ensuring that results are consistently available when looked for by clinicians. We assessed the real-life effectiveness and safety of implementing POC hs-cTn testing in the ED. METHODS We conducted a pragmatic, stepped-wedge cluster randomized trial. The control arm was usual care with an accelerated diagnostic pathway utilizing a single-sample rule-out step with a central laboratory hs-cTn assay. The intervention arm used the same pathway with a POC hs-cTnI. The primary effectiveness outcome was ED length of stay assessed using a generalized linear mixed model, and the safety outcome was 30-day MI or cardiac death. RESULTS Six sites participated with 59,980 ED presentations (44,747 individuals, 61±19 years, 49.5% female) from February 2023 to January 2025, in which 31,392 presentations were during the intervention arm. After adjustment for co-variates associated with length of stay, the intervention reduced length of stay by 13% (95% confidence intervals [CI], 9 to 16%. P<0.001), corresponding to a reduction of 47 minutes (95%CI, 33 to 61 minutes) from a mean length of stay in the control arm of 376 minutes. The 30-day MI or cardiac death rate was similar in the control and intervention arms (0.39% and 0.39% respectively, P=0.54). CONCLUSIONS Implementation of whole-blood hs-cTnI testing at the POC into an accelerated diagnostic pathway was safe and reduced length of stay in the ED compared with laboratory testing. (Australia New Zealand Clinical Trials Registry ACTRN12619001189112) Clinical Perspective What is new? Point-of-care troponin assays with good precision have become available and received regulatory approval as high-sensitivity assays. A pragmatic stepped-wedge cluster randomized trial implementing the validated Siemens VTLi high-sensitivity point-of-care assay into 6 emergency departments investigating ∼60,000 patients, was conducted to ascertain if the rapid turnaround time reduced lengths of stay. Introduction of the VTLi high-sensitivity point-of-care assay into clinical pathways reduced emergency department lengths of stay by an average 13% (47 minutes) without compromising safety. What are the clinical implications? Early decision-making using a point-of-care high-sensitivity troponin assay within a structured clinical pathway was safe. Faster turnaround means troponin results are consistently available when clinicians first seek them. This can facilitate earlier decisions and reduce patient length of stay.
Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 Assay
Knoll, Marko, Daniels, Lori B. , Mueller, Christian, Mills, Nicholas L, Giannitsis, Evangelos, Rösser, Alisa F A, Kurtoic, Dunja, Wahl, Annika , BODY, R. A. F., Christenson, R H, Cobbaert, Christa, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A. S., McCarthy, C. F., McCord, James, Neumann, Johannes T, Omland, Torbjørn, Papendick, Cynthia , Sandoval, Yader, Than, Martin P, Twerenbold, Raphael, Peacock, W Frank, Meex, Steven J. R., Giannitsis, Evangelos , Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mills, Nicholas L. , Mueller, Christian , Mills, Nicholas L , Giannitsis, Evangelos , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Daniels, Lori B , Cobbaert, Christa M. , deFilippi, Christopher R. , McCarthy, Cian P, McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Meex, Steven J.R.

The Journal of Applied Laboratory Medicine | March 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag031 Get It

Abstract Background High-sensitivity cardiac troponin (hs-cTn) assays are recommended for the diagnosis of acute myocardial infarction. Here, we characterize the analytical performance of a next-generation hs-cTn assay, Elecsys® Troponin T hs Gen 6 (Roche Diagnostics International). Methods Surplus lithium-heparin plasma or serum samples from patients or healthy volunteers were run on Cobas® e 801, e 402, and Pro analyzers. Limits of blank (LoB), limits of detection (LoD), and limits of quantitation (LoQ) were determined according to CLSI EP17-A2, with target values of 1.0 and 1.5 ng/L for LoB/LoD and 3.0 ng/L (10% CV) and 1.5 ng/L (20% CV) for LoQ, respectively. Precision was measured, per CLSI EP17-A2, using 3 QC samples (approximately 4, 30, and 220 ng/L), 12 native samples, and 3 reagent lots. Linearity, per CLSI EP06-Ed2, was determined by diluting samples with cardiac troponin T (cTnT) concentration above the measuring range with a low/blank sample. Interference (per Glick) with endogenous and assay components at 5 cTnT concentrations was assessed. Results Measured values for LoB, LoD, and LoQ at 10% and 20% CV were 0.1 to 0.7 ng/L, 0.3 to 1.4 ng/L, 1.0 to 2.9 ng/L, and 0.4 to 1.2 ng/L, respectively. Repeatability CVs were 1.0 to 5.8% for mean cTnT concentrations of 2.6 to 9230 ng/L in lithium-heparin plasma. High precision was shown across lots, and linearity was observed across the measuring range (1.5 to 9500 ng/L, all Pearson's r = 1.00). No interferences were observed, specified up to ≤1000 mg/dL hemoglobin, ≤50 mg/dL [≤855 µmol/L] icterus/bilirubin, and ≤1200 ng/mL biotin. Conclusions The analytical performance characterization of the assay demonstrated high sensitivity, high precision at the low end and across the measuring range, and resistance to interference.
Considerations and pragmatic strategies for implementation of point of care testing for high sensitivity cardiac troponin into the acute care setting
Collinson, Paul, Christenson, Robert, Jafri, Lena , Jaffe, Allan S., Apple, Fred S. , Hammarsten, Ola , Omland, Torbjørn, Sandoval, Yader, Mills, Nicholas L., Buchan, Vanessa, Sandberg, Sverre , Aakre, Kristin M., Aakre, Kristin M , Collinson, Paul , Lam, Leo , Pickering, John W. , Christenson, Robert H. , Hoovels, Lieve Van , Cullen, Louise , Jaffe, Allan S. , Omland, Torbjørn , Sandoval, Yader , Mills, Nicholas L , Than, Martin , Aakre, Kristin M.

Clinical Chemistry and Laboratory Medicine (CCLM) | March 5, 2026 | Volume: 64 | Issue: 7 | Pages: 1467-1478

10.1515/cclm-2026-0210 Get It

Abstract A challenge in the implementation of rapid risk-stratification algorithms for patients with suspected acute coronary syndrome is the turnaround time for cardiac troponin (cTn) from blood sampling to reporting of results. Measurement of cTn in whole blood using point of care (POC) offers a solution. There is lack of consensus on how these instruments should be assessed and deployed when implemented into routine practice. A pragmatic strategy is needed to balance the requirement for appropriate evaluation, validation and local verification of POC high sensitivity (hs) cTn assays whilst avoiding unnecessary duplication of previously conducted work using central laboratory assays. The International Federation of Clinical Chemistry and Laboratory Medicine Committee on Clinical Application of Cardiac Bio-Markers (IFCC C-CB) has developed an educational document to provide practical suggestions as to how hs-cTn POC assays may be implemented in acute health care settings and networks. The objective of this document is to provide a pragmatic framework for implementation of such systems. The article describes the validation and verification procedures and outlines what should be the responsibility of the manufacturers and provides recommendations on how a local verification may be undertaken before instruments are implemented into routine clinical practice.
Establishing Reference Values in Healthy Participants for the Cardiac Troponin T High-Sensitivity Gen 6 Assay: REF-TSIX Global Reference Study
Daniels, Lori B. , Mueller, Christian, Giannitsis, Evangelos, Meex, Steven J. R., Buehlmann, David, Dilba, Peter, Bendig, Garnet, Cole, Mette, Body, Richard, Christenson, Robert H, deFilippi, Christopher R, Inoue, Kenji, Jaffe, A S, McCarthy, Cian P. , McCord, J., Neumann, Johannes T, Omland, T., Papendick, Cynthia , Sandoval, Yader, Twerenbold, Raphael, Peacock, W Frank, Mills, Nicholas L, investigators, the TSIX, Jacobs, Michael B., Lucksinger, Gregg, Powell, Richard, Johnson, Daniel, Coleman, Hugh, Fein, M, Surber, Joseph, Vu, Jack B., Hassman, Michael, Hernandez, John, Kirstein, Judith, Tomaszewski, Christian, Runyon, Michael S. , Gong, Jonathan , Wein, D., Andrabi, Sara , Kopin, David , Larrain, Germain, Tahirkheli, Naheem, Clemency, Brian, Abdullah, Shuaib, Hira, Ravi S. , Klausner, H A, Mahler, Simon A. , Crystal, Chad, Headden, Gary, Chaille, Peter, Cannon, Chad Aaron, Limkakeng, Alexander, Tolia, Vaishal , Knapp, Barry J., Massoomi, Mohammad, Sandoval, Yader, Ko, Emily, Luzzi, Verónica, Christenson, Robert, Carson, Jennifer Powers , Cacioppo, F , Kolev, E., Petrov, Andrey, Hazarbasanov, Dobri , Simova, lana, Magimaiseelan, Luci Suganthi, Kosch, Christine, Klein, G, Mehltretter, Kai, Sauter, Joachim, Baumann, Sybille, Moeckel, Martin, Twerenbold, Raphael, Muller-Hennessen, Matthias, Biener, Moritz , Findeisen, P., Omland, Torbjøm, Wilczek-Kosowska, Urszula, Zimmer-Satora, Ewa, Krecipro-Nizińska, Ewa, Miró, O, Díaz, Víctor Jiménez , Mueller, C, Christ, Michael, Lynch, Stephen, BODY, R. A. F., Matsuki, Shunji, Eto, Takashi, Tanaka, Takanori, Hanada, Ryuzo, Nakagami, Takuo, Nakama, T, Kadota, K., Jing, Shan, Yu, Shuwen, Zhang, Hongxuan, Zhang, Jun, Huo, Yong, Zhang, Yan, Yan, Li, Jiang, Longyuan, Chen, Weiqiang, Huang, Jianying, Zhao, Yan, Guan, Ling, Yang, Yanhua, Zhang, Qin, Qiu, Zhaohui, Body, Richard , Neumann, Franz–Josef , Müller, Christian , Mueller, Christian , Body, Rick , Eggers, Kai M. , Jaffe, Allan S. , Neumann, Johannes T , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Mills, Nicholas L , Daniels, Lori B , Giannitsis, Evangelos , Meex, Steven J.R. , Christenson, Robert H. , Cobbaert, Christa M. , deFilippi, Christopher R. , McCord, James , Omland, Torbjørn , Sandoval, Yader , Tan, Jack Wei Chieh , Than, Martin , Twerenbold, Raphael , Surber, Joseph, Tomaszewski, Christian, Clemency, Brian, Headden, Gary , Cannon, Chad, Knapp, Barry , Tran, Nam K , Niederdöckl, Jan Daniel , Kolev, Emil, Popov, Todor, Sauter, Joachim, Baumann, Sybille , Möeckel, Martin , Müller‐Hennessen, Matthias, Findeisen, Peter, Scharnhorst, Volkher , Omland, T, Krecipro-Nizińska, Ewa, Christ, Michael , Nakagami, Takuo, Huo, Yong

Clinical Chemistry | January 18, 2026 | Volume: 72 | Issue: 4 | Pages: 488-502

10.1093/clinchem/hvag011 Get It

Abstract Background Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort. Methods Lithium-heparin plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 IFCC guidance. Uniform and sex-specific 99th percentile URLs and nonparametric 95% CIs were determined in plasma and serum separately and combined. Results The final study population comprised 4147 participants (52.5% female) with a median (25th–75th percentiles) age of 48.0 (33.0–59.0) years; 45.8%, 47.9%, 5.2%, and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n = 8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16–23) ng/L for females and 32 (28–35) ng/L for males; the uniform 99th percentile URL was 27 (24–31) ng/L. URLs were comparable in plasma and serum samples. Conclusions This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used in a large, global, healthy reference population.
Protocol for Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomised qua
Pickering, John W. , Devlin, Gerard, Aldous, Sally, Jaffe, Allan S. , Apple, Fred S. , Kavsak, Peter A. , Cullen, Louise , Lord, Sarah J. , Joyce, Laura R , Frampton, Chris , Than, Martin , Lord, Sarah J , Joyce, Laura , Richards, Arthur M , Than, Martin , Cullen, Louise , Body, Richard , Jaffe, Allan S. , Mills, Nicholas L , Troughton, Richard W. , Peacock, William Frank , Lacey, Cameron James , Richards, Mark , Pitama, Suzanne G

BMJ Open | June 13, 2024 | Volume: 14 | Issue: 6 | Pages: e083752

10.1136/bmjopen-2023-083752 Get It

Introduction Clinical assessment in emergency departments (EDs) for possible acute myocardial infarction (AMI) requires at least one cardiac troponin (cTn) blood test. The turn-around time from blood draw to posting results in the clinical portal for central laboratory analysers is ~1–2 hours. New generation, high-sensitivity, point-of-care cardiac troponin I (POC-cTnI) assays use whole blood on a bedside (or near bedside) analyser that provides a rapid (8 min) result. This may expedite clinical decision-making and reduce length of stay. Our purpose is to determine if utilisation of a POC-cTnI testing reduces ED length of stay. We also aim to establish an optimised implementation process for the amended clinical pathway. Methods and analysis This quality improvement initiative has a pragmatic multihospital stepped-wedge cross-sectional cluster randomised design. Consecutive patients presenting to the ED with symptoms suggestive of possible AMI and having a cTn test will be included. Clusters (comprising one or two hospitals each) will change from their usual-care pathway to an amended pathway using POC-cTnI—the ‘intervention’. The dates of change will be randomised. Changes occur at 1 month intervals, with a minimum 2 month ‘run-in’ period. The intervention pathway will use a POC-cTnI measurement as an alternate to the laboratory-based cTn measurement. Clinical decision-making steps and logic will otherwise remain unchanged. The POC-cTnI is the Siemens (Erlangen Germany) Atellica VTLi high-sensitivity cTnI assay. The primary outcome is ED length of stay. The safety outcome is cardiac death or AMI within 30 days for patients discharged directly from the ED. Ethics and dissemination Ethics approval has been granted by the New Zealand Southern Health and Disability Ethics Committee, reference 21/STH/9. Results will be published in a peer-reviewed journal. Lay and academic presentations will be made. Māori-specific results will be disseminated to Māori stakeholders. Trial registration number ACTRN12619001189112.
Sex-Specific Kinetics of High-Sensitivity Cardiac Troponin I and T following Symptom Onset and Early Presentation in Non-ST-Segment Elevation Myocardial Infarction
Sandoval, Yader , Chapman, Andrew R. , Mills, Nicholas L. , Than, Martin , Pickering, John W. , Worster, Andrew , Kavsak, Peter A. , Apple, Fred S. , Mills, Nicholas L , Than, Martin

Clinical Chemistry | October 15, 2020 | Volume: 67 | Issue: 1 | Pages: 321-324

10.1093/clinchem/hvaa263 Get It

Machine Learning to Predict the Likelihood of Acute Myocardial Infarction
Than, Martin , Sandoval, Yader , Shah, Anoop , Apple, Fred S. , Blankenberg, Stefan , Cullen, Louise , Mueller, Christian, Neumann, Franz–Josef , Twerenbold, Raphael , Westermann, Dirk , Beshiri, Agim , Mills, Nicholas L. , Collaborative, On behalf of the MI, George, Peter M., Richards, Mark , Aldous, Sally, Chapman, Andrew R. , Boeddinghaus, Jasper , Huang, Janel, Cullen, Louise , Mills, Nicholas L , Westermann, Dirk , Richards, Arthur M , Than, Martin , Pickering, John W. , Tsanas, Athanasios , Collaborative, On behalf of the MI, Troughton, Richard W. , Anand, Atul , Greenslade, Jaimi , Parsonage, William , Wildi, Karin , Nestelberger, Thomas , Badertscher, Patrick , Du, Shaoqing, Smith, Stephen W. , Sörensen, Nils Arne , Ojeda, Francisco , Boeddinghaus, Jasper , Blankenberg, Stefan , Neumann, Johannes T , Twerenbold, Raphael

Circulation | August 16, 2019 | Volume: 140 | Issue: 11 | Pages: 899-909

10.1161/circulationaha.119.041980 Get It

Background: Variations in cardiac troponin concentrations by age, sex, and time between samples in patients with suspected myocardial infarction are not currently accounted for in diagnostic approaches. We aimed to combine these variables through machine learning to improve the assessment of risk for individual patients. Methods: A machine learning algorithm (myocardial-ischemic-injury-index [MI 3 ]) incorporating age, sex, and paired high-sensitivity cardiac troponin I concentrations, was trained on 3013 patients and tested on 7998 patients with suspected myocardial infarction. MI 3 uses gradient boosting to compute a value (0–100) reflecting an individual’s likelihood of a diagnosis of type 1 myocardial infarction and estimates the sensitivity, negative predictive value, specificity and positive predictive value for that individual. Assessment was by calibration and area under the receiver operating characteristic curve. Secondary analysis evaluated example MI 3 thresholds from the training set that identified patients as low risk (99% sensitivity) and high risk (75% positive predictive value), and performance at these thresholds was compared in the test set to the 99th percentile and European Society of Cardiology rule-out pathways. Results: Myocardial infarction occurred in 404 (13.4%) patients in the training set and 849 (10.6%) patients in the test set. MI 3 was well calibrated with a very high area under the receiver operating characteristic curve of 0.963 [0.956–0.971] in the test set and similar performance in early and late presenters. Example MI 3 thresholds identifying low- and high-risk patients in the training set were 1.6 and 49.7, respectively. In the test set, MI 3 values were <1.6 in 69.5% with a negative predictive value of 99.7% (99.5–99.8%) and sensitivity of 97.8% (96.7–98.7%), and were ≥49.7 in 10.6% with a positive predictive value of 71.8% (68.9–75.0%) and specificity of 96.7% (96.3–97.1%). Using these thresholds, MI 3 performed better than the European Society of Cardiology 0/3-hour pathway (sensitivity, 82.5% [74.5–88.8%]; specificity, 92.2% [90.7–93.5%]) and the 99th percentile at any time point (sensitivity, 89.6% [87.4–91.6%]); specificity, 89.3% [88.6–90.0%]). Conclusions: Using machine learning, MI 3 provides an individualized and objective assessment of the likelihood of myocardial infarction, which can be used to identify low- and high-risk patients who may benefit from earlier clinical decisions. Clinical Trial Registration: URL: https://www.anzctr.org.au . Unique identifier: ACTRN12616001441404.
Detectable High-Sensitivity Cardiac Troponin within the Population Reference Interval Conveys High 5-Year Cardiovascular Risk: An Observational Study
Than, Martin , Aldous, Sally, Troughton, Richard W. , Pemberton, Christopher J, Richards, Mark , Frampton, Christopher , Florkowski, Christopher M , Bailey, Samantha, Young, Joanna M. , Cullen, Louise , Greenslade, Jaimi , Parsonage, William , Jaffe, Allan S. , Pickering, John W. , Cullen, Louise , Pemberton, Christopher J, George, Peter Myles , Everett, Brendan M. , Peacock, William Frank , Jaffe, Allan S. , Troughton, Richard W , Richards, Arthur M , Than, Martin

Clinical Chemistry | May 14, 2018 | Volume: 64 | Issue: 7 | Pages: 1044-1053

10.1373/clinchem.2017.285700 Get It

AbstractBACKGROUNDIncreased cardiac troponin I or T detected by high-sensitivity assays (hs-cTnI or hs-cTnT) confers an increased risk of adverse prognosis. We determined whether patients presenting with putatively normal, detectable cTn concentrations [&gt; limit of detection and &lt; upper reference limit (URL)] have increased risk of major adverse cardiovascular events (MACE) or all-cause mortality.METHODSA prospective 5-year follow-up of patients recruited in the emergency department with possible acute coronary syndrome (ACS) and cTn concentrations measured with hs-cTnI (Abbott) and hs-cTnT (Roche) assays. Cox regression models were generated with adjustment for covariates in those without MACE on presentation. Hazard ratios (HRs) for hs-cTn were calculated relative to the HRs at the median concentration.RESULTSOf 1113 patients, 836 were without presentation MACE. Of these, 138 incurred a MACE and 169 died during a median 5.8-year follow-up. HRs for MACE at the URLs were 2.3 (95% CI, 1.7–3.2) for hs-cTnI and 1.8 (95% CI, 1.3–2.4) for hs-cTnT. Corresponding HRs for mortality were 1.7 (95% CI, 1.2–2.2) for hs-cTnI and 2.3 (95 % CI, 1.7–3.1) for hs-cTnT. The HR for MACE increased with increasing hs-cTn concentration similarly for both assays, but the HR for mortality increased at approximately twice the rate for hs-cTnT than hs-cTnI. Patients with hs-cTnI ≥10 ng/L or hs-cTnT ≥16 ng/L had the same percentage of MACE at 5-year follow-up (33%) as patients with presentation MACE.CONCLUSIONSMany patients with ACS ruled out and putatively normal but detectable hs-cTnI concentrations are at similar long-term risk as those with MACE. hs-cTnT concentrations are more strongly associated with 5-year mortality than hs-cTnI.
ICare-ACS (Improving Care Processes for Patients With Suspected Acute Coronary Syndrome)
Than, Martin , Pickering, John W. , Dryden, Jeremy M., Lord, Sally J., Aldous, Sally, Allan, Kate , Ardagh, Michael, Bonning, John , Callender, Rosie, Chapman, Laura R.E., Christiansen, J., Cromhout, Andre P.J., Cullen, Louise , Deely, Joanne M., Devlin, Gerard, Ferrier, Katherine, Florkowski, Christopher M , Frampton, Christopher , George, Peter M., Hamilton, Gregory J. , Jaffe, Allan S. , Makower, R M, Matthews, Timothy James , Parsonage, William , Pelt, Niels C van, Poynton, Louise, Richards, Mark , Scott, Anthony, Simmonds, Mark, Smyth, David, Thomas, Oliver P., To, Andrew, Toit, Stephen A. Du, Troughton, Richard W. , Yates, Kim , Lord, Sarah J. , Cullen, Louise , Aitken, Stuart A. , Chapman, Laura , Jaffe, Allan S. , Kerr, Andrew Jensen , Larkin, Gregory Luke , Peacock, William Frank , Peckler, Brad , Toit, Stephen Du , Troughton, Richard W , Lord, Sarah J , Richards, Arthur M , Than, Martin

Circulation | November 15, 2017 | Volume: 137 | Issue: 4 | Pages: 354-363

10.1161/circulationaha.117.031984 Get It

Background: Efforts to safely reduce length of stay for emergency department patients with symptoms suggestive of acute coronary syndrome (ACS) have had mixed success. Few system-wide efforts affecting multiple hospital emergency departments have ever been evaluated. We evaluated the effectiveness of a nationwide implementation of clinical pathways for potential ACS in disparate hospitals. Methods: This was a multicenter pragmatic stepped-wedge before-and-after trial in 7 New Zealand acute care hospitals with 31 332 patients investigated for suspected ACS with serial troponin measurements. The implementation was a clinical pathway for the assessment of patients with suspected ACS that included a clinical pathway document in paper or electronic format, structured risk stratification, specified time points for electrocardiographic and serial troponin testing within 3 hours of arrival, and directions for combining risk stratification and electrocardiographic and troponin testing in an accelerated diagnostic protocol. Implementation was monitored for >4 months and compared with usual care over the preceding 6 months. The main outcome measure was the odds of discharge within 6 hours of presentation Results: There were 11 529 participants in the preimplementation phase (range, 284–3465) and 19 803 in the postimplementation phase (range, 395–5039). Overall, the mean 6-hour discharge rate increased from 8.3% (range, 2.7%–37.7%) to 18.4% (6.8%–43.8%). The odds of being discharged within 6 hours increased after clinical pathway implementation. The odds ratio was 2.4 (95% confidence interval, 2.3–2.6). In patients without ACS, the median length of hospital stays decreased by 2.9 hours (95% confidence interval, 2.4–3.4). For patients discharged within 6 hours, there was no change in 30-day major adverse cardiac event rates (0.52% versus 0.44%; P =0.96). In these patients, no adverse event occurred when clinical pathways were correctly followed. Conclusions: Implementation of clinical pathways for suspected ACS reduced the length of stay and increased the proportions of patients safely discharged within 6 hours. Clinical Trial Registration: URL: https://www.anzctr.org.au/ (Australian and New Zealand Clinical Trials Registry). Unique identifier: ACTRN12617000381381.