Back to Authors

Trzasko, Joshua D.

https://orcid.org/0000-0001-8180-5449

Mayo Clinic

Mayo Clinic

Citations 59

RF Noise Artifacts From a High Frequency Spinal Cord Stimulation System: A Retrospective Imaging Cohort With Illustrative Cases
Stinson, Eric G. , Hubbard, Abby, Kleinow, Jenna E. , Kramer, Emily A., Trzasko, Joshua D. , Shu, Yunhong , Edmonson, Heidi A. , Hubbard, Abby J, Hubbard, Abby J.

Journal of Magnetic Resonance Imaging | July 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/jmri.70394 Get It

ABSTRACT Unexpected RF noise artifact “followed” a patient with an implanted spinal cord stimulator to multiple MR systems. Subsequent testing and clinical scanning showed no artifact, implying that the artifact originated from the implanted device. MR exams ( n = 173) performed over a two‐year period in patients ( n = 122) who had implanted spinal cord stimulators from the same manufacturer were reviewed for artifacts and device models. RF noise artifacts were observed in ~50% of exams in patients with a specific model of spinal cord stimulator, but only ~1%–8% of exams in other models from the same manufacturer. We hope that by describing this artifact, health care professionals can avoid service costs and scheduling delays.
Cerebral Oxygen Budgeting: Network-Level BOLD Dynamics During Acute Hypoxia
Kang, Daehun, Haider, Clifton R. , In, Myung-Ho, Gray, Erin M. , Trzasko, Joshua D. , Welker, Kirk M., Senefeld, Jonathon W., Bernstein, Matt A., Holmes, David R., Joyner, M. J., Huston, John, Shu, Yunhong , Kang, Daehun , Kang, Daehun , Uchida, Koji, Curry, Timothy B. , Senefeld, Jonathon W , Uchida, Kôji , Campeau, Norbert G. , In, Myung‐Ho, Welker, Kirk M. , Wiggins, Chad C. , Senefeld, Jonathon W. , Baker, Sarah , Bernstein, Matt A. , Holmes, David R, Joyner, Michael J. , Huston, John

No container title available | March 31, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.03.27.713294 Get It

Abstract Hypoxia constrains cerebral oxygen availability and challenges brain function and stability. Although hypoxia-responsive functional connectivity (HR-FC) reorganizes rapidly with declining arterial oxygen partial pressure, its relationship to local neurovascular activity remains unclear. We examined time-resolved amplitude of low-frequency fluctuations (ALFF) in blood-oxygenation-level dependent (BOLD) fMRI during graded acute hypoxia in healthy adults, performing a continuous cognitive test (Go/No-go task) with concurrent physiological monitoring. Dynamic ALFF and functional connectivity were estimated using a sliding-window approach and analyzed across large-scale brain networks defined by Schaefer’s 17-network parcellation. Severe hypoxia elicited temporally dissociated responses across modalities. Functional connectivity increased monotonically, whereas ALFF exhibited pronounced nonlinear modulation, including phase-dependent divergence across networks. During hypoxic decompensation, the default mode network (DefaultA) showed marked ALFF suppression, whereas a ventral secondary somatosensory-dominant network (SomMotB) exhibited preferential preservation despite similar engagement in HR-FC. Together, these findings indicate that network-level ALFF captures a distinct yet complementary layer of functional dynamics, with a temporal profile distinct from functional connectivity. Spontaneous BOLD dynamics during acute hypoxia reflect structured network-level modulation rather than a uniform suppression attributable solely to reduced oxygen availability. These findings support a conceptual framework of cerebral oxygen budgeting , in which metabolic constraints reshape functional dynamics across brain networks.
Free‐Breathing, 3D Cardiac Magnetic Resonance Elastography for Myocardial Stiffness Mapping
Meyer, Nolan , Sui, Yi , Magnuson, Jessica , Rossman, Phillip J. , Glaser, Kevin J. , Murphy, Matthew C. , Manduca, Armando , Chang, Ian C , McGee, Kiaran P. , Kantarci, Kejal , Kapoor, Ekta , Araoz, Philip A. , Trzasko, Joshua D. , Arani, Arvin , Meyer, Nolan K , Ehman, Richard , Arani, Arvin , Manduca, A , Kantarci, Kejal , Sui, Yi , Ehman, Richard L.

Magnetic Resonance in Medicine | December 5, 2025 | Volume: 95 | Issue: 4 | Pages: 2356-2369

10.1002/mrm.70212 Get It

ABSTRACT Purpose Magnetic resonance elastography (MRE) of the heart has predominantly utilized breath‐held acquisitions with limited anatomic coverage. This work investigates the feasibility of 3D, free‐breathing cardiac MRE. Methods A 3D hybrid radial and EPI acquisition is utilized and combined with retrospective binning of k ‐space via physiologic monitoring, iterative reconstruction, MRE processing and inversions, and post‐processing specialized for cardiac imaging. Results Feasibility of free‐breathing stiffness mapping of the left ventricular myocardium was demonstrated in 11 participants. Myocardial stiffness estimates were obtained throughout the left ventricle for seven temporal states of the cardiac cycle. Stiffness estimates were presented in participant‐specific images, 17‐segment bullseye plots, and stiffness plots throughout the cardiac cycle. Results indicate increased stiffness in systolic states, with localized stiffness heterogeneity observed between participants, illustrating a key benefit of 3D cardiac MRE acquisition. Mean stiffness estimates obtained through 11 subjects were 4.44 ± 0.68 kPa (begin‐systole), 5.74 ± 0.94, 5.42 ± 0.87 (end‐systole), 3.84 ± 0.71 (begin‐diastole), 3.51 ± 0.74, 3.54 ± 0.52, and 3.55 ± 0.59 kPa (end‐diastole). Statistical testing indicated significant differences in stiffness across cardiac states with one‐way, repeated‐measures ANOVA ( p < 0.001) and Friedman's test ( p < 0.001). Experiments in scanning three participants with and without applied motion indicated that stiffness changes were more robustly detected in systole than in diastole, although patterns were subject‐specific. Comparison of free‐breathing stiffness measurements against reference breath‐held measurements yielded similar systolic stiffness estimates. Conclusions This study establishes the feasibility of free‐breathing, 3D cardiac MRE in healthy volunteers. With the current framework, stiffness estimation appears more robust in systole, and the reliability of diastolic estimates is limited and subject‐specific.
3D magnetization‐prepared rapid gradient echo with a RF saturation band on a compact 3T scanner
Speltz, Lydia J. Bardwell , In, Myung‐Ho , Trzasko, Joshua D. , Halverson, Maria, Gray, Erin M. , Shu, Yunhong , Bardwell Speltz, Lydia J , Gray, Erin, In, Myung-Ho , Kang, Daehun , Campeau, Norbert G. , Huston, John , Warner, David O. , Bernstein, Matt A.

Medical Physics | August 14, 2025 | Volume: 52 | Issue: 8 | Pages: No page available

10.1002/mp.18039 Get It

Abstract Background Flow‐related ghost artifact from a 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) sequence results from unsaturated magnetization of incoming arterial flow. This is especially common on MR scanners equipped with smaller radiofrequency (RF) transmit coils. A high‐performance compact 3T (C3T) scanner features a smaller RF‐transmit coil (inner diameter 37 cm, length 40 cm), leading to a rapid fall‐off of the B1 field below the neck. This configuration results in more intense flow‐related ghost artifacts, especially in younger patients. Purpose The C3T scanner's smaller RF‐transmit coil provides RF field coverage over the brain region, causing bright in‐flow arterial signals and flow‐related artifacts in the conventional 3D‐MPRAGE scans. The purpose of this study is to suppress these artifacts by adding a RF saturation band (RFSB) pulses to the 3D‐MPRAGE sequence. Methods The RFSB was added to the 3D‐MPRAGE sequence as a preparation pulse option. To test the effectiveness, 37 subjects were scanned on the C3T under an IRB‐approved protocol using 3D‐MPRAGE with and without RFSB. Ten of those subjects underwent repeated scans with and without RFSB to evaluate test‐retest reliability. A consensus evaluation by two neuroradiologists was performed on all data to compare signal to noise ratio, image contrast, presence of artifacts, and diagnostic confidence. Quantitative analysis included calculating test‐retest differences by image subtraction and evaluating the variance in flow‐artifact‐induced image intensity between the scans with and without RFSB. Additionally, one subject was scanned on a whole‐body 3T scanner using a transmit/receive (T/R) head coil to demonstrate the method's applicability across different MRI platforms as a proof of concept. Results The Wilcoxon signed‐rank test of the neuroradiologist evaluations showed a significant reduction in artifacts and an improvement in diagnostic confidence in the posterior fossa region with and without RFSB ( p < 0.0001). Test–retest analysis showed that adding RFSB significantly reduced image intensity variability in the cerebellum, even among subjects without visible flow artifacts. The normalized difference decreased from 8.71% to 6.41% ( p = 0.0059), suggesting improved image reliability in regions prone to flow‐related artifacts. Additionally, similar findings were observed in scans on a whole‐body 3T with a T/R head coil, demonstrating the broader applicability of this method. Conclusion Incorporating RFSB into 3D‐MPRAGE scans effectively reduces flow‐related ghost artifact on the C3T scanner, improving image quality and diagnostic confidence. These findings suggest that the proposed method could be widely implemented across MRI systems utilizing a smaller RF‐transmit coil.
Improved Curvelet Transform-based Sparsity Promoting Algorithm for Fast Ultrasound Localization Microscopy
Trzasko, Joshua D. , Zhang, Jingke , Chen, Shigao , Zhang, Jingke , Lok, U‐Wai , Huang, Chengwu , DeRuiter, Ryan M.

2024 IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) | December 18, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-3

10.1109/uffc-js60046.2024.10794058 Get It

GPU-based Blockwise Non-Local Means Filtering with Microbubble Separation for 3D Ultrasound Localization Microscopy
Trzasko, Joshua D. , Zhang, Jingke , Chen, Shigao , Zhang, Jingke , Lok, U‐Wai , Huang, Chengwu , DeRuiter, Ryan M.

2024 IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) | December 18, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/uffc-js60046.2024.10794030 Get It

Modeling the Acute Mucosal Toxicity of Fractionated Radiotherapy Combined with the ATM Inhibitor WSD0628
Garcia, D. , Rathi, Sneha , Connors, Margaret A. , Grams, Michael P. , Vaubel, Rachael A. , Bakken, Katrina K. , Ott, Lauren L. , Carlson, Brett L. , Hu, Zeng , Decker, Paul A. , Eckel‐Passow, Jeanette E. , Zhong, Wei , Trzasko, Joshua D. , Herman, Margot , Elmquist, William F. , Remmes, Nicholas B. , Garcia, Darwin A , Grams, Michael P , Burgenske, Danielle M , Zhong, Wei , Trzasko, Joshua D , Herman, Michael G , Elmquist, William F , Remmes, Nicholas B , Sarkaria, Jann N , Vaubel, Rachael A , Bakken, Katrina K , Decker, Paul A. , Burgenske, Danielle M. , Sarkaria, Jann N.

Molecular Cancer Therapeutics | November 19, 2024 | Volume: 24 | Issue: 2 | Pages: 299-309

10.1158/1535-7163.mct-24-0664 Get It

Abstract Ataxia Telangiectasia–mutated (ATM) inhibitors are being developed as radiosensitizers to improve the antitumor effects of radiotherapy, but ATM inhibition can also radiosensitize normal tissues. Therefore, understanding the elevated risk of normal tissue toxicities is critical for radiosensitizer development. This study focused on modeling the relationship between acute mucosal toxicity, radiation dose, fractionation schedule, and radiosensitizer exposure. The ATM inhibitor WSD0628 was combined with single or fractionated doses of radiation delivered to the oral cavity or esophagus of Friend Leukemia virus B (FVB) mice. The potentiation by WSD0628 was quantified by a sensitizer enhancement ratio (SER), which describes the changes in radiation tolerance for radiation combined with WSD0628 relative to radiation-only regimens. WSD0628 profoundly enhanced radiation-induced acute oral and esophageal toxicities. For oral mucosal toxicity, the enhancement by WSD0628 with 3 fractions of radiation resulted in an SER ranging from 1.3 (0.25 mg/kg) to 3.1 (7.5 mg/kg). For the 7.5 mg/kg combination, the SER increased with increasing number of fractions from 2.2 (1 fraction) to 4.3 (7 fractions) for oral toxicity and from 2.2 (1 fraction) to 3.6 (3 fractions) for esophageal toxicity, which reflects a loss of the normal tissue sparing benefit of fractionated radiation. These findings were used to develop a modified biologically effective dose model to determine alternative radiation schedules with or without WSD0628 that result in similar levels of toxicity. Successful radiosensitizer dose escalation to a maximally effective therapeutic dose will require careful deliberation of tumor site and reduction of radiation dose volume limits for organs at risk.
Modeling and measurement of lead tip heating and resonant length for implanted, insulated wires
Speltz, Lydia J. Bardwell , Shu, Yunhong , Tarasek, Matthew , Trzasko, Joshua D. , Bernstein, Matt A. , Bardwell Speltz, Lydia J , Bernstein, Matt A , Lee, Seung‐Kyun , Foo, Thomas

Magnetic Resonance in Medicine | May 31, 2024 | Volume: 92 | Issue: 4 | Pages: 1714-1727

10.1002/mrm.30145 Get It

AbstractPurposeTo study implant lead tip heating because of the RF power deposition by developing mathematical models and comparing them with measurements acquired at 1.5 T and 3 T, especially to predict resonant length.Theory and MethodsA simple exponential model and an adapted transmission line model for the electric field transfer function were developed. A set of wavenumbers, including that calculated from insulated antenna theory (King wavenumber) and that of the embedding medium were considered. Experiments on insulated, capped wires of varying lengths were performed to determine maximum temperature rise under RF exposure. The results are compared with model predictions from analytical expressions derived under the assumption of a constant electric field, and with those numerically calculated from spatially varying, simulated electric fields from body coil transmission. Simple expressions for the resonant length bounded between one‐quarter and one‐half wavelength are developed based on the roots of transcendental equations.ResultsThe King wavenumber for both models more closely matched the experimental data with a maximum root mean square error of 9.81°C at 1.5 T and 5.71°C at 3 T compared to other wavenumbers with a maximum root mean square error of 27.52°C at 1.5 T and 22.01°C for 3 T. Resonant length was more accurately predicted compared to values solely based on the embedding medium.ConclusionAnalytical expressions were developed for implanted lead heating and resonant lengths under specific assumptions. The value of the wavenumber has a strong effect on the model predictions. Our work could be used to better manage implanted device lead tip heating.
Locally Low-Rank Denoising of Multi-Echo Functional MRI Data With Application in Resting-State Analysis
Meyer, Nolan , Ahmed, Zaki , In, Myung‐Ho , Shu, Yunhong , Trzasko, Joshua D. , Meyer, Nolan K , In, Myung-Ho , Kang, Daehun , Huston, John , Bernstein, Matt A.

Topics in Magnetic Resonance Imaging | October 5, 2023 | Volume: 32 | Issue: 5 | Pages: 37-49

10.1097/rmr.0000000000000307 Get It

Abstract: Objectives: Locally low-rank (LLR) denoising of functional magnetic resonance imaging (fMRI) time series image data is extended to multi-echo (ME) data. The proposed method extends the capabilities of non-physiologic noise suppression beyond single-echo applications with a dedicated ME algorithm. Materials and Methods: Following an institutional review board (IRB) approved protocol, resting-state fMRI data were acquired in 7 healthy subjects. A compact 3T scanner enabled whole-brain acquisition of multiband ME fMRI data at high spatial resolution (1.4 × 1.4 × 2.8 mm3) with a 1810 ms repetition time (TR). Image data were denoised with ME-LLR preceding functional processing. The results of connectivity maps generated from denoised data were compared with maps generated with equivalent processing of non-denoised images. To assess ME-LLR as a method to reduce scan time, comparisons were made between maps computed from image data with full and retrospectively truncated durations. Assessments were completed with seed-based connectivity analyses using echo-combined image data. In a feasibility assessment, nondenoised and denoised full-duration echo-combined data were equivalently processed with independent component analysis (ICA) and compared. Results: ME-LLR denoising yielded strengthened resting-state network connectivity maps after nuisance regression and seed-based connectivity analysis. In assessing ME-LLR as a scan reduction mechanism, maps generated from denoised data at half scan time showed comparable quality with maps generated from full-duration, non-denoised data, at both single subject and group levels. ME-LLR substantially increased temporal signal-to-noise ratio (tSNR) for image data respective to each individual echo and for image data after nuisance regression. Among echo-specific image volumes, increases in tSNR yielded by ME-LLR were most pronounced for image data with the longest echo time and thereby lowest SNR. ICA showed resting-state networks consistently identified between non-denoised and denoised data, with clearer demarcation of networks for ME-LLR. Conclusions: ME-LLR is demonstrated to suppress non-physiologic noise, enhance functional connectivity map quality, and could potentially facilitate scan time reduction in ME-fMRI.