Back to Authors

DeRuiter, Ryan M.

https://orcid.org/0000-0003-2135-6607

Mayo Clinic

Mayo Clinic

Citations 10

Contrast-Free Ultrasound Microvascular Imaging via Radiality and Similarity Weighting
Yin, Jingyi , Zhang, Jingke , Huang, Lijie , DeRuiter, Ryan M. , Ji, Kaipeng , Zhao, Yanzhe , Knoll, Kate M , Petersen, Kendra E , Wu, Tao , Zhu, Xiang, Krier, James D., Robinson, Kathryn A. , Lerman, Lilach O. , Petersen, Kendra E. , Yin, Jingyi , Zhang, Jingke , DeRuiter, Ryan , Lok, U‐Wai , Bentall, Andrew , Chen, Shigao , Huang, Chengwu

IEEE Transactions on Ultrasonics | June 3, 2026 | Volume: 73 | Issue: 7 | Pages: 775-790

10.1109/tuson.2026.3699956 Get It

Fast 3-D Ultrasound Localization Microscopy via Projection-Based Processing Framework
Zhang, Jingke , Yin, Jingyi , Huang, Lijie , DeRuiter, Ryan M. , Ji, Kaipeng , Zhao, Yanzhe , Krier, James D., Zhu, Xiang, Lerman, Lilach O. , Yin, Jingyi , Zhang, Jingke , DeRuiter, Ryan , Lok, U‐Wai , Wu, Tao , Ji, Kaipeng, Huang, Chengwu , Chen, Shigao

IEEE Transactions on Medical Imaging | May 15, 2026 | Volume: 45 | Issue: 7 | Pages: 4105-4122

10.1109/tmi.2026.3692792 Get It

Mapping Microvascular Flow via Radon Transform Ultrasound: Technical Advances and Pilot Application
Yin, Jingyi , Huang, Lijie, Zhang, Jingke , DeRuiter, Ryan M., Zhu, Xiang-yang, Krier, James D., Kim, Y, Zhao, Y., Ji, Kaipeng , Lerman, L. O., Chen, S., Huang, Chengwu , Zhao, Yanzhe , Huang, Chengwu , Zhang, Jingke , Huang, Lijie, Lok, U‐Wai , DeRuiter, Ryan M. , Lucien, Fabrice , Lerman, Lilach O.

BME Frontiers | January 30, 2026 | Volume: 7 | Issue: No issue available | Pages: No page available

10.34133/bmef.0234 Get It

Objective: This study aims to develop a contrast-free, high-sensitivity ultrasound method, denoted as Radon transform-based flow measurement (R-Flow), for in vivo mapping of microvascular flow vectors and for establishing R-Flow-derived vector-field metrics to noninvasively quantify microcirculatory patterns in liver cirrhosis. Impact Statement: R-Flow enables robust, contrast-free imaging of microvascular dynamics and demonstrates translational feasibility in the human liver. Its direction-aware indices offer pilot in vivo quantification of flow redistribution and remodeling, providing unique insights into hepatic flow dynamics. Introduction: Microvascular dysfunction is a hallmark of many diseases, yet noninvasive visualization and quantitative assessment of abnormal microcirculation remain limited. Methods: R-Flow leverages Radon transform to decode red blood cell dynamics from the spatiotemporal domain of ultrasound flow signals, reconstructing velocity vectors at microvascular scale. From these vector maps, unique direction-aware indices are further derived to characterize flow distribution and heterogeneity. Results: Validated across simulations, phantoms, and in vivo studies, R-Flow provides robust velocity estimation across a wide range (1 to 60 mm/s). Notably, it enables high-sensitivity microvascular flow vector mapping of human liver, showing strong agreement with references ( r > 0.9). In a rat model, these direction-aware indices revealed a shift from healthy multipath perfusion in control livers to directionally biased vascular pattern in cirrhotic livers, demonstrating significant correlation with pathological indicators. Conclusion: R-Flow enables noninvasive, contrast-free mapping of microvascular blood flow velocity and offers a promising approach for high-resolution assessment of microvascular flow characteristics.
Ultrasound Localization Microscopy to Assess the Intrarenal Microvasculature in Autosomal Dominant Polycystic Kidney Disease
Huang, Chengwu , Abd-Elfattah, Ahmed Saleh , DeRuiter, Ryan M. , Zhang, Nathan , Knoll, Kate M , Petersen, Kendra E. , Wu, Tao , Hogan, Marie C. , Eirin, Alfonso , Lerman, Lilach O. , Irazabal, María V. , Abdelfattah, Ahmed , Zhang, Youwen, Hogan, Marie C , Eirin, Alfonso , Lerman, Lilach O , Irazabal, Maria V , Huang, Chengwu , DeRuiter, Ryan , Petersen, Kendra E , Zhang, Nathan , Zhang, Youwen , Chen, Shigao

Journal of the American Society of Nephrology | December 9, 2025 | Volume: 37 | Issue: 6 | Pages: 1221-1236

10.1681/asn.0000000968 Get It

Key Points The kidney microvasculature was quantified reliably in human autosomal dominant polycystic kidney disease early on, using super-resolution ultrasound localization microscopy. Microvascular parameters correlated with structural and functional indices, constituting promising biomarkers to evaluate noncystic parenchyma. Microvascular parameters may serve to assess disease severity and monitor progression from the early stages of the disease. Background In vitro studies in individuals with autosomal dominant polycystic kidney disease (ADPKD) have shown extensive intrarenal microvascular remodeling. However, analyses have been limited to the time of kidney failure because of the invasive nature of current methodologies to assess the intrarenal microvasculature. We hypothesized that super-resolution ultrasound microvascular imaging, known as ultrasound localization microscopy, enabled by high-framerate ultrasound imaging and microbubble localization and tracking postprocessing techniques, would safely, reliably, and reproducibly assess the intrarenal microvasculature in individuals with ADPKD at an early stage of the disease. Methods We prospectively enrolled young (<40 years of age), well-characterized, early-stage (eGFR >90 ml/min per 1.73 m 2 ) individuals with ADPKD, and sex–age 1:1 matched controls ( n =17 each) and assessed the intrarenal microvasculature using ultrasound localization microscopy. We determined the intersonographer reliability, intraobserver repeatability, and interobserver reproducibility of microvascular parameters in both groups, and the day-to-day variability in the control group. Microvascular parameters were correlated with structural (total kidney volume) and functional (eGFR) markers in individuals with ADPKD. Results Ultrasound localization microscopy provided a super-resolved map of the intrarenal microvasculature in ADPKD and matched controls. Intrarenal microvascular parameters ( e.g ., vessel density) were quantified in a safe, reliable (intraclass correlation coefficients, 0.96; 95% confidence interval, 0.91 to 0.98), reproducible (intraclass correlation coefficient, 0.96; 95% confidence interval, 0.93 to 0.98), and repeatable (coefficient of variations, 3.6%) manner. In control individuals, the day-to-day variability of most parameters was low, with coefficient of variation ranging from 1.8% to 10.7%. Microvascular parameters differed in individuals with ADPKD compared with controls, despite preserved eGFR. Interestingly, cortical vessel density and its derived perfusion correlated directly with eGFR, whereas tortuosity indices presented an inverse correlation. Conclusions Ultrasound localization microscopy provided a safe and reliable in vivo assessment of the human intrarenal microvasculature.
Enhanced Contrast-Free in vivo 3D Ultrasound Microvessel Imaging using Hadamard Multipulse Diverging Wave Transmission and Denoising with a 32×32 Matrix array
Zhang, Jingke , Huang, Lijie , Yin, Jingyi , Chen, Shigao , Zhang, Jingke , Lok, U‐Wai , Huang, Chengwu , DeRuiter, Ryan M.

2025 IEEE International Ultrasonics Symposium (IUS) | October 20, 2025 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/ius62464.2025.11201304 Get It

Super-resolution ultrasound imaging of microvasculature: Initial experiences in preclinical and clinical applications
Huang, Chengwu , Lok, U‐Wai , Zhang, Jingke , DeRuiter, Ryan M. , Chen, Shigao

The Journal of the Acoustical Society of America | July 18, 2025 | Volume: 157 | Issue: 4_Supplement | Pages: A22-A22

10.1121/10.0037263 Get It

Ultrasound localization microscopy (ULM) enables imaging of the microvasculature at spatial resolutions surpassing the limits of conventional ultrasound, while maintaining comparable penetration depth. This super-resolution technique relies on the localization and tracking of individual microbubbles (MBs) administered into the bloodstream, providing detailed visualization of microvascular structures and functions. However, clinical implementation of ULM faces significant challenges, such as low signal-to-noise ratio (SNR), tissue motion artifacts, and prolonged acquisition times. In this presentation, we will discuss advancements aimed at achieving robust and reproducible clinical implementation of ULM through a series of technical innovations and optimizations. These include signal enhancement techniques to boost MB SNR, advanced algorithms for accurate MB localization and tracking at clinically relevant dosages, optimized data acquisition strategies tailored to clinical workflows, and the development of 3-D imaging capabilities. Through pilot preclinical and clinical studies, we demonstrate the feasibility and efficacy of ULM in various applications, including chronic kidney disease (CKD), kidney transplant, liver disease evaluation, and beyond, in both animal models and human subjects under clinical scanning conditions. These findings underscore the transformative potential of super-resolution ultrasound imaging as a diagnostic tool, paving the way for widespread clinical adoption.
Improving Imaging Field of View of 3-D Transcranial Rat Brain Super-Resolution With Robotic Registered Compounding and Nonrigid Deformation Correction
DeRuiter, Ryan M. , Jones, Rebecca M. , Belgharbi, Hatim , Sode, Masashi , Lee, Hanjoo , Santibáñez, Francisco , Dayton, Paul A. , Pinton, Gianmarco , DeRuiter, Ryan

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | May 29, 2025 | Volume: 72 | Issue: 7 | Pages: 889-905

10.1109/tuffc.2025.3574916 Get It

Improved Curvelet Transform-based Sparsity Promoting Algorithm for Fast Ultrasound Localization Microscopy
Trzasko, Joshua D. , Zhang, Jingke , Chen, Shigao , Zhang, Jingke , Lok, U‐Wai , Huang, Chengwu , DeRuiter, Ryan M.

2024 IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) | December 18, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-3

10.1109/uffc-js60046.2024.10794058 Get It

GPU-based Blockwise Non-Local Means Filtering with Microbubble Separation for 3D Ultrasound Localization Microscopy
Trzasko, Joshua D. , Zhang, Jingke , Chen, Shigao , Zhang, Jingke , Lok, U‐Wai , Huang, Chengwu , DeRuiter, Ryan M.

2024 IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) | December 18, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/uffc-js60046.2024.10794030 Get It

Novel Quantitative Liver Steatosis Assessment Method With Ultrasound Harmonic Imaging
Zhang, Jingke , Huang, Chengwu , Tang, Shanshan , Liu, Hui , DeRuiter, Ryan M. , Petersen, Kendra E , Knoll, Kate M , Robinson, Kathryn, Watt, Kymberly D., Callstrom, Matthew R. , Chen, Shigao , Petersen, Kendra E. , Zhang, Jingke , Lok, U-Wai , Liu, Hui , DeRuiter, Ryan , Petersen, Kendra, Knoll, Kate, Watt, Kymberly, Callstrom, Matthew, Huang, Chengwu , Gong, Ping , Lok, U‐Wai , Robinson, Kathryn

Journal of Ultrasound in Medicine | September 24, 2024 | Volume: 44 | Issue: 1 | Pages: 77-85

10.1002/jum.16582 Get It

ObjectivesMetabolic dysfunction‐associated steatotic liver disease (MASLD) is the most prevalent liver disorder in Western countries, with approximately 20%–30% of the MASLD patients progressing to severe stages. There is an urgent need for noninvasive, cost‐effective, widely accessible, and precise biomarkers to evaluate liver steatosis. This study aims to assess and compare the diagnostic performance of a novel reference frequency method‐based ultrasound attenuation coefficient estimation (ACE) in both fundamental (RFM‐ACE‐FI) and harmonic (RFM‐ACE‐HI) imaging for detecting and grading liver steatosis.MethodsAn Institutional Review Board‐approved prospective study was carried out between December 2018 and October 2022. A total number of 130 subjects were enrolled in the study. The correlation between RFM‐ACE‐HI values and magnetic resonance imaging proton density fat fraction (MRI‐PDFF), as well as between RFM‐ACE‐FI values and MRI‐PDFF were calculated. The diagnostic performance of RFM‐ACE‐FI and RFM‐ACE‐HI was evaluated using receiver operating characteristic (ROC) curve analysis, as compared to MRI‐PDFF. The reproducibility of RFM‐ACE‐HI was assessed by interobserver agreement between two sonographers.ResultsA strong correlation was observed between RFM‐ACE‐HI and MRI‐PDFF, with R = 0.88 (95% confidence interval [CI]: 0.83–0.92; P < .001), while the correlation between RFM‐ACE‐FI and MRI‐PDFF was R = 0.65 (95% CI: 0.50–0.76; P < .001). The area under the ROC (AUROC) curve for RFM‐ACE‐HI in staging liver steatosis grades of S ≥ 1 and S ≥ 2 was 0.97 (95% CI: 0.91–0.99; P < .001) and 0.98 (95% CI: 0.93–1.00; P < .001), respectively, and 0.76 (95% CI: 0.65–0.85) and 0.80 (95% CI: 0.70–0.88) for RFM‐ACE‐FI, respectively. Great reproducibility was achieved for RFM‐ACE‐HI, with an interobserver agreement of R = 0.97 (95% CI: 0.94–0.99; P < .001).ConclusionsThe novel RFM‐ACE‐HI method offered high liver steatosis diagnostic accuracy and reproducibility, which has important clinical implications for early disease intervention and treatment evaluation.