Back to Authors

Petersen, Kendra E.

https://orcid.org/0000-0001-7479-2168

Mayo Clinic

Mayo Clinic

Citations 4

Contrast-Free Ultrasound Microvascular Imaging via Radiality and Similarity Weighting
Yin, Jingyi , Zhang, Jingke , Huang, Lijie , DeRuiter, Ryan M. , Ji, Kaipeng , Zhao, Yanzhe , Knoll, Kate M , Petersen, Kendra E , Wu, Tao , Zhu, Xiang, Krier, James D., Robinson, Kathryn A. , Lerman, Lilach O. , Petersen, Kendra E. , Yin, Jingyi , Zhang, Jingke , DeRuiter, Ryan , Lok, U‐Wai , Bentall, Andrew , Chen, Shigao , Huang, Chengwu

IEEE Transactions on Ultrasonics | June 3, 2026 | Volume: 73 | Issue: 7 | Pages: 775-790

10.1109/tuson.2026.3699956 Get It

Ultrasound Localization Microscopy to Assess the Intrarenal Microvasculature in Autosomal Dominant Polycystic Kidney Disease
Huang, Chengwu , Abd-Elfattah, Ahmed Saleh , DeRuiter, Ryan M. , Zhang, Nathan , Knoll, Kate M , Petersen, Kendra E. , Wu, Tao , Hogan, Marie C. , Eirin, Alfonso , Lerman, Lilach O. , Irazabal, María V. , Abdelfattah, Ahmed , Zhang, Youwen, Hogan, Marie C , Eirin, Alfonso , Lerman, Lilach O , Irazabal, Maria V , Huang, Chengwu , DeRuiter, Ryan , Petersen, Kendra E , Zhang, Nathan , Zhang, Youwen , Chen, Shigao

Journal of the American Society of Nephrology | December 9, 2025 | Volume: 37 | Issue: 6 | Pages: 1221-1236

10.1681/asn.0000000968 Get It

Key Points The kidney microvasculature was quantified reliably in human autosomal dominant polycystic kidney disease early on, using super-resolution ultrasound localization microscopy. Microvascular parameters correlated with structural and functional indices, constituting promising biomarkers to evaluate noncystic parenchyma. Microvascular parameters may serve to assess disease severity and monitor progression from the early stages of the disease. Background In vitro studies in individuals with autosomal dominant polycystic kidney disease (ADPKD) have shown extensive intrarenal microvascular remodeling. However, analyses have been limited to the time of kidney failure because of the invasive nature of current methodologies to assess the intrarenal microvasculature. We hypothesized that super-resolution ultrasound microvascular imaging, known as ultrasound localization microscopy, enabled by high-framerate ultrasound imaging and microbubble localization and tracking postprocessing techniques, would safely, reliably, and reproducibly assess the intrarenal microvasculature in individuals with ADPKD at an early stage of the disease. Methods We prospectively enrolled young (<40 years of age), well-characterized, early-stage (eGFR >90 ml/min per 1.73 m 2 ) individuals with ADPKD, and sex–age 1:1 matched controls ( n =17 each) and assessed the intrarenal microvasculature using ultrasound localization microscopy. We determined the intersonographer reliability, intraobserver repeatability, and interobserver reproducibility of microvascular parameters in both groups, and the day-to-day variability in the control group. Microvascular parameters were correlated with structural (total kidney volume) and functional (eGFR) markers in individuals with ADPKD. Results Ultrasound localization microscopy provided a super-resolved map of the intrarenal microvasculature in ADPKD and matched controls. Intrarenal microvascular parameters ( e.g ., vessel density) were quantified in a safe, reliable (intraclass correlation coefficients, 0.96; 95% confidence interval, 0.91 to 0.98), reproducible (intraclass correlation coefficient, 0.96; 95% confidence interval, 0.93 to 0.98), and repeatable (coefficient of variations, 3.6%) manner. In control individuals, the day-to-day variability of most parameters was low, with coefficient of variation ranging from 1.8% to 10.7%. Microvascular parameters differed in individuals with ADPKD compared with controls, despite preserved eGFR. Interestingly, cortical vessel density and its derived perfusion correlated directly with eGFR, whereas tortuosity indices presented an inverse correlation. Conclusions Ultrasound localization microscopy provided a safe and reliable in vivo assessment of the human intrarenal microvasculature.
Novel Quantitative Liver Steatosis Assessment Method With Ultrasound Harmonic Imaging
Zhang, Jingke , Huang, Chengwu , Tang, Shanshan , Liu, Hui , DeRuiter, Ryan M. , Petersen, Kendra E , Knoll, Kate M , Robinson, Kathryn, Watt, Kymberly D., Callstrom, Matthew R. , Chen, Shigao , Petersen, Kendra E. , Zhang, Jingke , Lok, U-Wai , Liu, Hui , DeRuiter, Ryan , Petersen, Kendra, Knoll, Kate, Watt, Kymberly, Callstrom, Matthew, Huang, Chengwu , Gong, Ping , Lok, U‐Wai , Robinson, Kathryn

Journal of Ultrasound in Medicine | September 24, 2024 | Volume: 44 | Issue: 1 | Pages: 77-85

10.1002/jum.16582 Get It

ObjectivesMetabolic dysfunction‐associated steatotic liver disease (MASLD) is the most prevalent liver disorder in Western countries, with approximately 20%–30% of the MASLD patients progressing to severe stages. There is an urgent need for noninvasive, cost‐effective, widely accessible, and precise biomarkers to evaluate liver steatosis. This study aims to assess and compare the diagnostic performance of a novel reference frequency method‐based ultrasound attenuation coefficient estimation (ACE) in both fundamental (RFM‐ACE‐FI) and harmonic (RFM‐ACE‐HI) imaging for detecting and grading liver steatosis.MethodsAn Institutional Review Board‐approved prospective study was carried out between December 2018 and October 2022. A total number of 130 subjects were enrolled in the study. The correlation between RFM‐ACE‐HI values and magnetic resonance imaging proton density fat fraction (MRI‐PDFF), as well as between RFM‐ACE‐FI values and MRI‐PDFF were calculated. The diagnostic performance of RFM‐ACE‐FI and RFM‐ACE‐HI was evaluated using receiver operating characteristic (ROC) curve analysis, as compared to MRI‐PDFF. The reproducibility of RFM‐ACE‐HI was assessed by interobserver agreement between two sonographers.ResultsA strong correlation was observed between RFM‐ACE‐HI and MRI‐PDFF, with R = 0.88 (95% confidence interval [CI]: 0.83–0.92; P < .001), while the correlation between RFM‐ACE‐FI and MRI‐PDFF was R = 0.65 (95% CI: 0.50–0.76; P < .001). The area under the ROC (AUROC) curve for RFM‐ACE‐HI in staging liver steatosis grades of S ≥ 1 and S ≥ 2 was 0.97 (95% CI: 0.91–0.99; P < .001) and 0.98 (95% CI: 0.93–1.00; P < .001), respectively, and 0.76 (95% CI: 0.65–0.85) and 0.80 (95% CI: 0.70–0.88) for RFM‐ACE‐FI, respectively. Great reproducibility was achieved for RFM‐ACE‐HI, with an interobserver agreement of R = 0.97 (95% CI: 0.94–0.99; P < .001).ConclusionsThe novel RFM‐ACE‐HI method offered high liver steatosis diagnostic accuracy and reproducibility, which has important clinical implications for early disease intervention and treatment evaluation.
Sonographic Assessment of Renal Transplant Anastomotic Pseudoaneurysm: A Case Study
Petersen, Kendra E. , Hunt, Talisha M. , McMenomy, Brendan P., Prieto, Mikel , Petersen, Kendra E

Journal of Diagnostic Medical Sonography | May 23, 2022 | Volume: 38 | Issue: 6 | Pages: 575-583

10.1177/87564793221100267 Get It

Renal transplant anastomotic pseudoaneurysms (RTAPs) are a rare vascular postoperative complication. The etiology of these pseudoaneurysms is attributed to infection or surgical vessel damage. RTAPs can lead to allograft dysfunction, allograft loss, or patient mortality due to rupture or sepsis. Because of these serious complications, expedient diagnosis is imperative for initiating surgical intervention and medical management. Sonography is a useful imaging modality for diagnosing and characterizing RTAPs. The sonographic findings, although not often described in detail in the literature, are definitive and unique. This case report describes the sonographic findings of a patient 22 days post renal autotransplant, who presented with excruciating abdominal pain. Sonographic examination identified multiple classic pseudoaneurysm findings and demonstrated intrarenal and extrarenal vascular abnormalities.