Objective: This study aims to develop a contrast-free, high-sensitivity ultrasound method, denoted as Radon transform-based flow measurement (R-Flow), for in vivo mapping of microvascular flow vectors and for establishing R-Flow-derived vector-field metrics to noninvasively quantify microcirculatory patterns in liver cirrhosis. Impact Statement: R-Flow enables robust, contrast-free imaging of microvascular dynamics and demonstrates translational feasibility in the human liver. Its direction-aware indices offer pilot in vivo quantification of flow redistribution and remodeling, providing unique insights into hepatic flow dynamics. Introduction: Microvascular dysfunction is a hallmark of many diseases, yet noninvasive visualization and quantitative assessment of abnormal microcirculation remain limited. Methods: R-Flow leverages Radon transform to decode red blood cell dynamics from the spatiotemporal domain of ultrasound flow signals, reconstructing velocity vectors at microvascular scale. From these vector maps, unique direction-aware indices are further derived to characterize flow distribution and heterogeneity. Results: Validated across simulations, phantoms, and in vivo studies, R-Flow provides robust velocity estimation across a wide range (1 to 60 mm/s). Notably, it enables high-sensitivity microvascular flow vector mapping of human liver, showing strong agreement with references ( r > 0.9). In a rat model, these direction-aware indices revealed a shift from healthy multipath perfusion in control livers to directionally biased vascular pattern in cirrhotic livers, demonstrating significant correlation with pathological indicators. Conclusion: R-Flow enables noninvasive, contrast-free mapping of microvascular blood flow velocity and offers a promising approach for high-resolution assessment of microvascular flow characteristics.
Enhanced Contrast-Free in vivo 3D Ultrasound Microvessel Imaging using Hadamard Multipulse Diverging Wave Transmission and Denoising with a 32×32 Matrix array
2024 IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) | December 18, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-3
2024 IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) | December 18, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-4
ObjectivesMetabolic dysfunction‐associated steatotic liver disease (MASLD) is the most prevalent liver disorder in Western countries, with approximately 20%–30% of the MASLD patients progressing to severe stages. There is an urgent need for noninvasive, cost‐effective, widely accessible, and precise biomarkers to evaluate liver steatosis. This study aims to assess and compare the diagnostic performance of a novel reference frequency method‐based ultrasound attenuation coefficient estimation (ACE) in both fundamental (RFM‐ACE‐FI) and harmonic (RFM‐ACE‐HI) imaging for detecting and grading liver steatosis.MethodsAn Institutional Review Board‐approved prospective study was carried out between December 2018 and October 2022. A total number of 130 subjects were enrolled in the study. The correlation between RFM‐ACE‐HI values and magnetic resonance imaging proton density fat fraction (MRI‐PDFF), as well as between RFM‐ACE‐FI values and MRI‐PDFF were calculated. The diagnostic performance of RFM‐ACE‐FI and RFM‐ACE‐HI was evaluated using receiver operating characteristic (ROC) curve analysis, as compared to MRI‐PDFF. The reproducibility of RFM‐ACE‐HI was assessed by interobserver agreement between two sonographers.ResultsA strong correlation was observed between RFM‐ACE‐HI and MRI‐PDFF, with R = 0.88 (95% confidence interval [CI]: 0.83–0.92; P < .001), while the correlation between RFM‐ACE‐FI and MRI‐PDFF was R = 0.65 (95% CI: 0.50–0.76; P < .001). The area under the ROC (AUROC) curve for RFM‐ACE‐HI in staging liver steatosis grades of S ≥ 1 and S ≥ 2 was 0.97 (95% CI: 0.91–0.99; P < .001) and 0.98 (95% CI: 0.93–1.00; P < .001), respectively, and 0.76 (95% CI: 0.65–0.85) and 0.80 (95% CI: 0.70–0.88) for RFM‐ACE‐FI, respectively. Great reproducibility was achieved for RFM‐ACE‐HI, with an interobserver agreement of R = 0.97 (95% CI: 0.94–0.99; P < .001).ConclusionsThe novel RFM‐ACE‐HI method offered high liver steatosis diagnostic accuracy and reproducibility, which has important clinical implications for early disease intervention and treatment evaluation.
Enhancing Row-Column Array (RCA)-Based 3D Ultrasound Vascular Imaging With Spatial-Temporal Similarity Weighting
AbstractErectile dysfunction (ED) caused by cavernous nerve injury (CNI) is refractory to heal mainly ascribed to the adverse remodeling of the penis induced by ineffectual microvascular perfusion, fibrosis, and neurotrophins scarcity in cavernosum. Phosphodiesterase type V inhibitors (PDE5i) have been regarded as an alternative candidate drug for avoiding penile neuropathy. However, the therapeutic efficacy is severely limited due to poor accumulation under systemic medication and endogenous nitric oxide (NO) deficiency in cavernosum. Herein, an innovative liposomal microbubble (MB) loaded with both Sildenafil (one of PDE5i) and NO was designed. Ultrasound‐targeted MB destruction (UTMD)‐mediated efficient release and integration erectogenic agents into corpus cavernosum with high biosafety. On a bilateral CNI rat model, the multifunctional MB‐cooperated UTMD improved microvascular perfusion in penis, simultaneously, alleviated hypoxia and oxidative stress, indicating successful activation of NO–cyclic guanosine monophosphate pathway. Also, evaluation of the endothelial/muscular composition, intracavernosal pressure, and neural integrity in the penis proved that coordinated intervention reversed the abnormal structural remodeling and promoted the recovery of functional erection. Our work demonstrates that MB loading Sildenafil and NO combined with UTMD hold great promise to “awaken” the efficacy of PDE5i in neurogenic ED, which provided a superior option for ensuring penile rehabilitation.
In vivo assessment of hypertensive nephrosclerosis using ultrasound localization microscopy
AbstractPurposeAs a typical chronic kidney disease (CKD), hypertensive nephrosclerosis (HN) is a common syndrome of hypertension, characterized by chronic kidney microvascular damage. Early diagnosis of microvascular damage using conventional ultrasound imaging encounters challenges in sensitivity and specificity owing to the inherent diffraction limit. Ultrasound localization microscopy (ULM) has been developed to obtain microvasculature and microvascular hemodynamics within the kidney, and would be a promising tool for the early diagnosis of CKD.MethodsIn this study, the advantage of quantitative indexes obtained by using ULM (mean arterial blood flow speeds of different segments of interlobular arteries) over indexes obtained using conventional clinical serum (β2‐microglobulin, serum urea nitrogen, and creatinine) and urine (24‐h urine volume and urine protein) tests and ultrasound Doppler imaging (peak systolic velocity [PSV], end‐diastolic velocity [EDV], and resistance index [RI]) and contrast‐enhanced ultrasound imaging (CEUS; rise time [RT], peak intensity [IMAX], mean transit time [mTT], and area under the time‐intensity curve [AUC]) for early diagnosis of HN were investigated. Examinations were carried out on six spontaneously hypertensive rats (SHR) and five normal Wistar–Kyoto (WKY) rats at the age of 10 weeks.ResultsThe experimental results show that the indicators derived from conventional clinical inspections (serum and urine tests) and ultrasound imaging (PSV, EDV, RI, RT, IMAX, mTT, and AUC) do not show significant difference between hypertensive and healthy rats (p > 0.05), while the TTP of the SHR group (28.52 ± 5.52 s) derived from CEUS is significantly higher than that of the WKY group (18.68 ± 7.32 s; p < 0.05). The mean blood flow speed in interlobular artery of SHR (12.47 ± 1.06 mm/s) derived from ULM is significantly higher than that of WKY rats (10.13 ± 1.17 mm/s; p < 0.01).ConclusionThe advantages of ULM over conventional clinical inspections and ultrasound imaging methods for early diagnosis of HN were validated. The quantitative results show that ULM can effectively diagnose HN at the early stage by detecting the blood flow speed changes of interlobular arteries. ULM may promise a reliable technique for early diagnosis of HN in the future.