Performing 3D ultrasound imaging at a real-time volume rate (e.g., >20 Hz) is a challenging task. While 2D array transducers remain the most practical approach for real-time 3D imaging, the large number of transducer elements (e.g., several thousand) that are necessary to cover an effective 3D field-of-view impose a fundamental constraint on imaging speed. Although solutions such as multiplexing and specialized transducers, including sparse arrays and row-column-addressing arrays, have been developed to address this limitation, they inevitably compromise imaging quality (e.g., SNR, resolution) in favor of speed. Coupled with the high equipment cost of 2D arrays, these compromises hinder the widespread adoption of 3D ultrasound imaging technologies in clinical settings. In this presentation, we introduce an innovative transducer clip-on device comprising a water-immersible, fast-tilting electromechanical acoustic reflector and a redirecting reflector to enable real-time 3D ultrasound imaging using common 1D array transducers. We will first introduce the principles underlying our novel technique, followed by validation studies incorporating simulation and experimental data. We will also demonstrate the feasibility of using the clip-on device to achieve a high 3D imaging volume rate that is suitable for advanced imaging modes such as shear wave elastography, blood flow imaging, and super-resolution ultrasound localization microscopy.
Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array
Objective . To develop a 3D shear wave elastography (SWE) technique using a 2D row column addressing (RCA) array, with either external vibration or acoustic radiation force (ARF) as the shear wave source. Impact Statement . The proposed method paves the way for clinical translation of 3D SWE based on the 2D RCA, providing a low-cost and high volume rate solution that is compatible with existing clinical systems. Introduction . SWE is an established ultrasound imaging modality that provides a direct and quantitative assessment of tissue stiffness, which is significant for a wide range of clinical applications including cancer and liver fibrosis. SWE requires high frame rate imaging for robust shear wave tracking. Due to the technical challenges associated with high volume rate imaging in 3D, current SWE techniques are typically confined to 2D. Advancing SWE from 2D to 3D is significant because of the heterogeneous nature of tissue, which demands 3D imaging for accurate and comprehensive evaluation. Methods . A 3D SWE method using a RCA array was developed with a volume rate up to 2000 Hz. The performance of the proposed method was systematically evaluated on tissue-mimicking elasticity phantoms and in an in vivo case study. Results . 3D shear wave motion induced by either external vibration or ARF was successfully detected with the proposed method. Robust 3D shear wave speed maps were reconstructed for phantoms and in vivo . Conclusion . The high volume rate 3D imaging provided by the 2D RCA array provides a robust and practical solution for 3D SWE with a clear pathway for future clinical translation.
Curvelet Transform-Based Sparsity Promoting Algorithm for Fast Ultrasound Localization Microscopy