Background: Accurate identification of patients with metabolic dysfunction–associated steatohepatitis (MASH) at risk of disease progression (at-risk MASH) is critical for guiding resmetirom and semaglutide therapy. Inconsistent definitions of at-risk MASH complicate clinical risk classification and comparisons across studies. This study aimed to standardize the definition of at-risk MASH and propose optimized MRE-based liver stiffness (LS-MRE) cutoffs to improve noninvasive risk stratification and better guide pharmacotherapy. Methods: In this prospective study, 413 patients with suspected or diagnosed MASLD from two medical centers underwent liver biopsy and MRE. Results: A simplified definition of at-risk MASH (MASH with fibrosis stage≥2) identified a broader group of patients requiring clinical attention than a stricter definition requiring NAFLD Activity Score≥4 with ≥1 point in steatosis, inflammation, and ballooning (n=122 vs. 77). LS-MRE alone showed the highest diagnostic accuracy for identifying at-risk MASH using the simplified definition (AUC 0.91 [0.87, 0.95]) and cirrhosis (AUC 0.93 [0.88, 0.99]), compared with FIB-4 and individual laboratory parameters (AST, ALT, and platelet count) ( p <0.01 for all, paired DeLong tests). Optimized LS-MRE cutoffs (2.8–6.4 kPa) captured 25 additional biopsy-proven pharmacotherapy candidates (28% of all eligible patients) compared to AASLD guidelines–recommended cutoffs (3.1–4.4 kPa), improving sensitivity (80% vs. 50%) with acceptable specificity (73% vs. 88%). Conclusions: A simplified definition of at-risk MASH enables broader identification of treatment candidates. LS-MRE demonstrates excellent diagnostic performance and improves noninvasive risk stratification when paired with optimized cutoffs. These findings support the use of MRE to guide resmetirom and semaglutide eligibility and improve access to emerging therapies.
Tissue Strain Mapping via Magnetic Resonance Elastography Can Be Used to Detect Active Lesion Expansion
ABSTRACT Purpose Active lesion expansion is clinically important because it can indicate disease progression and influence management and treatment planning. However, sequential imaging is often unavailable, and rapid growth can only be inferred from indirect findings such as active perilesional tissue injury. This study aimed to implement and test the feasibility of an MR elastography (MRE)‐based technique for assessing the expansile nature of mass lesions by detecting stiffness changes caused by mechanical strain manifestations in adjacent tissues. Methods A tissue strain mapping (TSM) algorithm was developed using spatial–temporal directional filtering to reveal the presence of perilesional latent strain that is not apparent in conventional MRE inversions. The technical feasibility was tested in tissue‐simulating phantoms containing a mass that was progressively expanded. Preliminary feasibility for clinical application was also demonstrated in representative in vivo examples. Resulting TSM maps were compared with conventional MRE stiffness maps. Results In the phantom experiments, TSM revealed the presence of local strain at the periphery of the expanding mass, with the effect increasing proportionally to the degree of expansion. Conventional MRE did not demonstrate comparable localized stiffening patterns. In vivo examples showed similar perilesional strain features that were not apparent on conventional MRE maps. Conclusion The feasibility of the proposed MRE‐based TSM technique was demonstrated in phantom and preliminary in vivo studies. These findings suggest that the technique is a promising tool for assessing the expansile nature of mass lesions and motivate further development of the TSM processing and exploration of potential clinical applications.
Free‐Breathing,
3D
Cardiac Magnetic Resonance Elastography for Myocardial Stiffness Mapping
ABSTRACT Purpose Magnetic resonance elastography (MRE) of the heart has predominantly utilized breath‐held acquisitions with limited anatomic coverage. This work investigates the feasibility of 3D, free‐breathing cardiac MRE. Methods A 3D hybrid radial and EPI acquisition is utilized and combined with retrospective binning of k ‐space via physiologic monitoring, iterative reconstruction, MRE processing and inversions, and post‐processing specialized for cardiac imaging. Results Feasibility of free‐breathing stiffness mapping of the left ventricular myocardium was demonstrated in 11 participants. Myocardial stiffness estimates were obtained throughout the left ventricle for seven temporal states of the cardiac cycle. Stiffness estimates were presented in participant‐specific images, 17‐segment bullseye plots, and stiffness plots throughout the cardiac cycle. Results indicate increased stiffness in systolic states, with localized stiffness heterogeneity observed between participants, illustrating a key benefit of 3D cardiac MRE acquisition. Mean stiffness estimates obtained through 11 subjects were 4.44 ± 0.68 kPa (begin‐systole), 5.74 ± 0.94, 5.42 ± 0.87 (end‐systole), 3.84 ± 0.71 (begin‐diastole), 3.51 ± 0.74, 3.54 ± 0.52, and 3.55 ± 0.59 kPa (end‐diastole). Statistical testing indicated significant differences in stiffness across cardiac states with one‐way, repeated‐measures ANOVA ( p < 0.001) and Friedman's test ( p < 0.001). Experiments in scanning three participants with and without applied motion indicated that stiffness changes were more robustly detected in systole than in diastole, although patterns were subject‐specific. Comparison of free‐breathing stiffness measurements against reference breath‐held measurements yielded similar systolic stiffness estimates. Conclusions This study establishes the feasibility of free‐breathing, 3D cardiac MRE in healthy volunteers. With the current framework, stiffness estimation appears more robust in systole, and the reliability of diastolic estimates is limited and subject‐specific.
MR
Elastography‐Based Slip Interface Imaging for Assessment of Myofascial Interface Mobility in Chronic Low Back Pain: A Pilot Study
ABSTRACT Purpose Abnormal restrictions at myofascial interfaces are a key factor in chronic low back pain (CLBP) with myofascial pain syndrome (MPS), but no established imaging method exists for quantitative assessment. This pilot study evaluated the clinical feasibility of MR elastography (MRE)‐based slip interface imaging (SII) for visualizing myofascial mobility in CLBP‐MPS patients versus age−/sex‐/BMI‐matched healthy participants. A new SII biomarker, maximal normalized displacement discontinuity (), was introduced, and the previously developed normalized octahedral shear strain (NOSS) map was used for comparison. Preliminary assessments of vibration‐frequency effects, repeatability, and group differences in inter‐muscular mobility were conducted. Methods MRE was conducted at 30, 60, and 90 Hz to compare with NOSS for visualizing inter‐muscular slip interfaces at the quadratus lumborum‐erector spinae (QL‐ES) and erector spinae‐multifidus (ES‐M) muscle boundaries at L3‐L4. Repeatability of and NOSS was assessed at 30 Hz (identified as the best‐performing frequency) using within‐subject coefficients of variation and a linear mixed‐effects model from within‐ and between‐day scans. Clinical feasibility was then assessed via Wilcoxon rank‐sum tests in six CLBP‐MPS patients and matched controls. Results at 30 Hz exhibited superior delineation of slip interfaces compared to higher frequencies and NOSS. demonstrated significantly lower variation and better repeatability than NOSS. Healthy participants showed continuous, well‐defined slip interfaces, whereas CLBP‐MPS patients displayed disrupted interfaces with significant mobility reduction at L4 ES‐M. Conclusion SII with lower vibration frequency and map enhances visualization of lower back myofascial mobility and shows potential for assessing differences between healthy individuals and CLBP‐MPS patients.
Detection of transient tissue displacement using wavelet MR elastography: Phantom validation and in vivo human brain repeatability study
AbstractPurposeWhile standard MR elastography (MRE) uses harmonic mechanical waves, there are some applications in which imaging and analysis of transient mechanical motion are of interest. Wavelet MRE has been developed for detecting broadband motion from transient excitation. The goal of this study was to evaluate the accuracy and efficiency of wavelet MRE for transient displacement detection in brain MRE applications.MethodsTransient motion was induced in a gel phantom, while MRE images were acquired using bipolar motion‐encoding gradient (MEG) at multiple frequencies (20–200 Hz). Displacements were estimated using (1) combinations of multiple MEGs forming the wavelet MRE and (2) deconvolution from a single MEG. These estimated displacements were used to calculate the MRE phase for each MEG. Correlation (r2) between the calculated and acquired phases was evaluated.Three healthy volunteers were scanned twice in a clinical scanner using wavelet MRE with an occipital impact. Time‐resolved brain translation, rotation, and maximal principal strain were calculated. Repeatability was assessed both qualitatively and through Pearson correlation.ResultsWavelet MRE outperformed standard MRE in displacement estimation, showing higher correlations between calculated and acquired phase, even with fewer phase offsets. In the volunteer study, consistent temporal motion dynamics and spatial maximal principal strain distributions across repeated scans demonstrated the repeatability of wavelet MRE.ConclusionThis study validated the accuracy and efficiency of wavelet MRE for broadband motion detection and demonstrated its feasibility and repeatability in vivo. This technique shows promise for advancing our understanding of the injury risks and mechanisms associated with sports‐related head trauma.
Three-Dimensional Vector MR Elastography for Evaluating Tissue Mechanical Heterogeneity to Assess Liver Disease Progression
Abstract Purpose To evaluate the test–retest repeatability of a rapid, free‐breathing two‐dimensional (2D) MR elastography (MRE) technique and to assess the reliability of the liver‐stiffness measurements compared with conventional breath‐hold MREs. Methods Fifteen and 115 participants were enrolled in the technical repeatability and measurement equivalence assessment cohorts, respectively. All participants underwent rapid free‐breathing and conventional breath‐hold 2D MRE (twice in repeatability cohort) on 1.5T scanners. Both methods have four phase offsets over one harmonic motion cycle at 60 Hz; one and 10 cycles were collected and processed in breath‐hold and free‐breathing MREs, respectively. The liver stiffness measurements of free‐breathing (LS F ) and breath‐hold MRE (LS B ) were calculated from manually drawn regions of interest. The repeatability coefficients and Spearman correlation were used to assess technical repeatability and measurement agreement between LS F and LS B . Univariable and multivariable linear regressions were performed to identify potential influencing factors, including age, sex, body mass index, and fat fraction, in the measurement agreement between LS B and LS F . Results The repeatability coefficient of free‐breathing 2D MRE is comparable to breath‐hold MRE (LS F : 20.8%, LS B : 20.4%). LS F showed a strong agreement and significant correlation with LS B (LS F = 1.01 × LS B , ρ = 0.94, p < 0.001). The measurement agreement between LS F and LS B was only significantly affected by sex ( p = 0.047) after adjusting for confounding factors of age, body mass index, and fat fraction. Conclusions The nongated, free‐breathing, multislice 2D MRE technique can provide reliable liver stiffness measurements compared with conventional breath‐hold 2D MRE. It could provide a comfortable alternative method with reliable liver stiffness measurements for patients who have difficulty in suspending respiration.
Three‐Dimensional MR Elastography of Microvascular Invasion
AbstractPurposeAbnormal adherence at functional myofascial interfaces is hypothesized as an important phenomenon in myofascial pain syndrome. This study aimed to investigate the feasibility of MR elastography (MRE)–based slip interface imaging (SII) to visualize and assess myofascial mobility in healthy volunteers.MethodsSII was used to assess local shear strain at functional myofascial interfaces in the flexor digitorum profundus (FDP) and thighs. In the FDP, MRE was performed at 90 Hz vibration to each index, middle, ring, and little finger. Two thigh MRE scans were performed at 40 Hz with knees flexed and extended. The normalized octahedral shear strain (NOSS) maps were calculated to visualize myofascial slip interfaces. The entropy of the probability distribution of the gradient NOSS was computed for the two knee positions at the intermuscular interface between vastus lateralis and vastus intermedius, around rectus femoris, and between vastus intermedius and vastus medialis.ResultsNOSS map depicted distinct functional slip interfaces in the FDP for each finger. Compared to knee flexion, clearer slip interfaces and larger gradient NOSS entropy at the vastus lateralis–vastus intermedius interface were observed during knee extension, where the quadriceps are not passively stretched. This suggests the optimal position for using SII to visualize myofascial slip interface in skeletal muscles is when muscles are not subjected to any additional force.ConclusionThe study demonstrated that MRE‐based SII can visualize and assess myofascial interface mobility in extremities. The results provide a foundation for investigating the hypothesis that myofascial pain syndrome is characterized by changes in the mobility of myofascial interfaces.