Citations

Mayo Clinic

Clear

192 citation(s) found for "Fu, Shuai".

Hi-c FFPE sequencing analysis is highly concordant with FISH and detects additional variants informing diagnosis and treatment in diffuse large B-cell lymphoma
Wu, Dehong , Wang, Chang , Visco, Carlo, Chiu, April , Xu, Mina L. , Tam, Wayne , Wen, Shuai, Zu, Youli , Pan, Zenggang , Bernal‐Mizrachi, Leon , Krieken, Joannes H.J.M. Van, Choi, William , Chen, Weina , Ferreri, Andrés J.M. , Moeller, Michael, Sikkink, Kristin , Schmitt, Anthony D. , Zu, Youli , Xu‐Monette, Zijun Y. , Tzankov, Alexandar , Visco, Carlo , Hsi, Eric D. , Dybkær, Karen , Wen, Shuai, Wang, Bangchen , Bhagat, Govind , Montes‐Moreno, Santiago , Ponzoni, Maurilio , Parsons, Benjamin M. , Li, Yong , Hastie, Alex R. , Young, Ken H.

Blood | December 5, 2025 | Volume: 146 | Issue: Supplement 1 | Pages: 3529-3529

10.1182/blood-2025-3529 Get It

Abstract Background: Diffuse large B-cell lymphoma (DLBCL) is the most common type of non-Hodgkin lymphoma (NHL), accounting for approximately 30% of all NHL cases. DLBCL diagnosis relies on histologic examination, immunophenotyping, molecular and fluorescence in situ hybridization (FISH) analysis to differentiate it from similar NHL subtypes with overlapping morphological features, including more high-grade lymphomas like double-hit lymphoma. Because FISH is performed in a panel of single- or dual-target test format and analyzed through microscopy and manual image analysis, assessment of multiple target biomarkers can be cumbersome and expensive. As additional biomarkers for diagnosis, subtyping, prognosis, and therapeutic decision-making become available, target panels will become larger, posing additional challenges to clinical laboratories. Patients and Methods In this study, Hi-C sequencing of FFPE samples was performed to identify all genomic rearrangements by a single sequencing analysis for an unselected DLBCL case series of 159 patients, and the results were compared to FISH for the detection of clinically important variants. Results Hi-C sequencing showed superior performance compared to FISH: standard FISH for DLBCL includes testing for MYC, BCL2, and BCL6. Between FISH and Hi-C, these biomarkers were detected 105 times, of which, FISH detected 80/105 (76%) and Hi-C detected 102/105 (97%). The cohort included 4 double-hit lymphomas by FISH but Hi-C sequencing detected five. Besides DLBCL diagnostic biomarkers (MYC, BCL2, BCL6), many additional biomarkers were detected by Hi-C sequencing including variants not tested by FISH because the clinical suspicion was ambiguous and the relevant FISH probes were not used, and those not tested because the biomarkers were not thought to be common and, hence, left out of the FISH panel. In total, Hi-C sequencing detected additional biomarkers in 42 (26%) cases, including (1) variants targeted by FISH (i.e. MYC, BCL2, BCL6) but negative, (2) classification biomarkers for other lymphomas (CCND1, MALT, IRF4), and (3) those not tested because the biomarkers are not common and not included in the FISH panel. These additional biomarkers were supportive of suspected diagnosis of DLBCL versus double-hit lymphoma (24 cases), prompted reconsideration of a different diagnosis that may have led to different treatments (6 cases, e.g. mantle cell lymphoma), or biomarkers such as PDL1, ALK, and ATM which have implications for targeted therapies and/or inclusion in clinical trials (5 cases). Conclusion The Hi-C FFPE sequencing technology has the potential to improve the workflow of pathology labs for detection of a wide range of structural variants informing precision diagnosis and treatment for lymphomas.
Threshold-Based Overlap of Breast Cancer High-Risk Classification Using Family History, Polygenic Risk Scores, and Traditional Risk Models in 180,398 Women
Ho, Peh Joo , Loo, Christine Kim Yan , Lim, Ryan Jak Yang, Goh, Mui Heng, Abubakar, Mustapha , Ahearn, Thomas U. , Andrulis, Irene L. , Antonenkova, Natalia, Aronson, Kristan J. , Augustinsson, Annelie , Behrens, Sabine , Bodelón, Clara , Bogdanova, Natalia , Bolla, Manjeet K. , Brantley, Kristen D. , Brenner, Hermann , Byers, Helen L., Camp, Nicola J. , Cessna, Melissa H., Chang-Claude, Jenny, Choi, Ji-Yeob , Czene, Kamila , Dörk, Thilo , Eliassen, A. Heather , Engel, Christoph , Eriksson, Mikael , Evans, D. Gareth , Fritschi, Lin , Genkinger, Jeanine M. , Geurts-Giele, Willemina R.R. , Glendon, Gord, Hall, Per , Hamann, U. , Ho, Cecilia Y.S., Hooning, Maartje J. , Hoppe, Reiner , Humphreys, Keith , Ito, Hidemi , Jakubowska, Anna , Jernström, Helena , John, Esther M. , Johnson, Nichola , Kang, Daehee , Kim, Sung‐Won , Kitahara, Cari M. , Ko, Yon-Dschun, Kraft, Peter, Kwong, Ava , Lambrechts, Diether, Larsson, Susanna C. , Li, Shuai , Lindblom, Annika , Linet, Martha, Lissowska, Jolanta , Lophatananon, Artitaya , MacInnis, Robert J. , Mannermaa, Arto, Manoukian, Siranoush, Margolin, Sara, Matsuo, Keitaro , Michailidou, Kyriaki , Taib, Nur Aishah Mohd , Murphy, Rachel A. , Newman, William G. , Obi, Nadia , Olopade, Olufunmilayo I., Panayiotidis, Mihalis I. , Park, Sue K. , Park‐Simon, Tjoung‐Won , Patel, Alpa V , Peterlongo, Paolo , Plaseska‐Karanfilska, Dijana , Pylkäs, Katri , Rashid, Muhammad Usman , Rodríguez, Juan , Sandler, Dale P. , Sawyer, Elinor J. , Scott, Christopher G. , Shahi, Shamim , Shu, Xiao‐Ou , Shulman, Katerina, Simard, Jacques , Southey, Melissa C., Stone, Jennifer , Taylor, Jack A. , Teo, Soo‐Hwang , Teras, Lauren R. , Vachon, Celine M., Houdt, Maxime Van , Verhoeven, Jelle , Weinberg, Clarice R. , Wolk, Alicja , Yamaji, Taiki , Yip, Cheng Har , Zheng, Wei , Hartman, Mikael , Li, Jingmei , Investigators, on behalf of the ABCTB, Investigators, kConFab, Investigators, MyBrCa, Investigators, SGBCC, Olopade, Olufunmilayo I. , Lambrechts, Diether , Lambrechts, Diether , Hamann, Ute , Hooning, Maartje J. , Bogdanova, Natalia V , Czene, Kamila , Dörk, Thilo , Eliassen, A Heather , Engel, Christoph , Eriksson, Mikael , Evans, D Gareth , Fletcher, Olivia , Fritschi, Lin , Genkinger, Jeanine , Hall, Per N , Ho, Cecilia Y S , Humphreys, Keith , Ito, Hidemi , Jakubowska, Anna , Jernström, Helena , Johnson, Nichola , Kim, Sung-Won , Kitahara, Cari M , Kwong, Ava , Larsson, Susanna C , Li, Shuai , Lindblom, Annika , Lissowska, Jolanta , Lophatananon, Artitaya , Maclnnis, Robert , Matsuo, Keitaro , Michailidou, Kyriaki , Mohd Taib, Nur Aishah , Murphy, Rachel A , Newman, William G , Obi, Nadia , Panayiotidis, Mihalis I , Park, Sue K , Park-Simon, Tjoung-Won , Peterlongo, Paolo , Plaseska-Karanfilska, Dijana , Pylkäs, Katri , Rashid, Muhammad U , Rennert, Gad , Rodriguez, Juan , Sandler, Dale P , Sawyer, Elinor J , Scott, Christopher , Shu, Xiao-Ou , Simard, Jacques , Stone, Jennifer , Taylor, Jack A , Teo, Soo H , Teras, Lauren R , Houdt, Maxime Van , Verhoeven, Jelle , Weinberg, Clarice R , Wolk, Alicja , Zheng, Wei , Hartman, Mikael , Li, Jingmei , Lambrechts, Diether , Behrens, Sabine , John, Esther M , Olopade, Olufunmilayo I , Lambrechts, Diether , Augustinsson, Annelie , Brenner, Hermann , Camp, Nicola J , Brantley, Kristen D , Lim, Ryan Jak Yang, Byers, Helen, Castelao, Jose E. , Chang‐Claude, Jenny , Chanock, Stephen Jacob , Chenevix‐Trench, Georgia , Colonna, Sarah V. , Daly, Mary Beryl , Derouane, Françoise , Fletcher, Olivia , Gago-Domínguez, Manuela , Ho, Weang-Kee , Howell, Anthony , Iwasaki, Motoki , Ko, Yon‐Dschun, Mannermaa, Arto , Manoukian, Siranoush , Margolin, Sara , Milne, Roger L. , Muir, Kenneth , O’Brien, Katie M. , Rennert, Gad , Saloustros, Emmanouil , Southey, Melissa C. , Terry, Mary Beth , Torres, Diana , Investigators, on behalf of the ABCTB, Investigators, kConFab, Investigators, MyBrCa, Investigators, SGBCC

Cancers | November 3, 2025 | Volume: 17 | Issue: 21 | Pages: 3561

10.3390/cancers17213561 | PMID 41228354 Get It

Background: Breast cancer polygenic risk scores (PRS) and traditional risk models (e.g., the Gail model [Gail]) are known to contribute largely independent information, but it is unclear how the overlap varies by ancestry, age, disease type (invasive breast cancer, DCIS), and risk threshold. Methods: In a retrospective case–control study, we evaluated risk prediction performance in 180,398 women (161,849 of European ancestry; 18,549 of Asian ancestry). Odds ratios (ORs) from logistic regression models and the area under the receiver operating characteristic curve (AUC) were estimated. Results: PRS for invasive disease showed a stronger association in younger (<50 years) women (OR = 2.51, AUC = 0.622) than in women ≥ 50 years (OR = 2.06, AUC = 0.653) of European ancestry. PRS performance in Asians was lower (OR range = 1.62–1.64, AUC = 0.551–0.600). Gail performance was modest across groups and poor in younger Asian women (OR = 0.94–0.99, AUC = 0.523–0.533). Age interactions were observed for both PRS (p < 0.001) and Gail (p < 0.001) in Europeans, whereas in Asians, age interaction was observed only for Gail (invasive: p < 0.001; DCIS: p = 0.002). PRS identified more high-risk individuals than Gail in Asian populations, especially ≥50 years, while Gail identified more in Europeans. Overlap between PRS, Gail, and family history was limited at higher thresholds. Calibration analysis, comparing empirical and model-based ROC curves, showed divergence for both PRS and Gail (p < 0.001), which indicates miscalibration. In Europeans, family history and prior biopsies drove Gail discrimination. In younger Asians, age at first live birth was influential. Conclusions: PRS adds value to risk stratification beyond traditional tools, especially in younger women and Asian ancestry populations.
Adult Abdominal Photon-Counting CT Protocols: A Multiinstitutional Consensus of the Society of Abdominal Radiology Photon-Counting Detector CT Emerging Technology Commission
Anathakrishnan, Lakshmi, Marin, Daniele , Toia, Giuseppe V. , Borhani, Amir A. , Chung, Ryan , Morgan, Desiree E. , Dane, Bari , Schwartz, Fides R. , Leng, Shuai , Fletcher, Joel G.

American Journal of Roentgenology | October 8, 2025 | Volume: 225 | Issue: 6 | Pages: No page available

10.2214/ajr.25.33625 | PMID 41060190 Get It

Technical performance of dual‐contrast‐agent K‐edge imaging with four energy thresholds on a commercial photon counting detector CT
Treb, Kevin , Marsh, Jeffrey F., Shanblatt, Elisabeth R. , Nowak, Tristan , Dunning, Chelsea A. S. , Fung, George S. K. , Schmidt, Bernhard , McCollough, C, Leng, Shuai, Treb, Kevin J, Treb, Kevin , Leng, Shuai

Medical Physics | October 8, 2025 | Volume: 52 | Issue: 10 | Pages: No page available

10.1002/mp.70063 | PMID 41058552 Get It

Abstract Background Photon counting detector CT (PCD‐CT) has the potential to sort detected x‐ray photons into more than two energy bins to perform multi‐material decomposition using K‐edge materials without additional mathematical constraints/assumptions. The availability of multiple energy thresholds in PCD‐CT opens the possibility for unique clinical applications such as simultaneous multi‐contrast‐agent imaging. Purpose To evaluate the technical performance of a PCD‐CT system with four energy thresholds for conducting multi‐material decomposition of iodine, gadolinium, and water after a comprehensive system calibration procedure. Methods Experiments were performed on a commercial PCD‐CT scanner (NAEOTOM Alpha, Siemens Healthineers) using a research mode with four energy thresholds. Material calibration was performed by scanning contrast materials with known concentration placed in various sizes of cylindrical water‐equivalent phantoms at various tube currents and positions. From these data, per‐voxel contrast models were derived for each material by multiple linear regressions up to second order, where the predictor variables were combinations of tube current, phantom diameter, and distance to isocenter. After calibration, small (20 cm diameter) and large (30 cm × 40 cm) uniform multi‐energy CT phantoms and an anthropomorphic thorax phantom (31 cm × 39 cm), each containing bone, soft tissue, and several quantitative inserts of iodine (0.2–5.0 mg/ml), gadolinium (0.3–5.0 mg/ml), and a mixture of both (5.0 mg/ml each) were scanned using the four‐energy threshold mode at 140 kV with energy thresholds set at 20, 52, 75, and 82 keV. Images for each energy threshold were reconstructed with a filtered back‐projection algorithm and a quantitative kernel (Qr44). Subsequent image‐based material decomposition was performed on individual voxels of the energy threshold images using the models derived from the calibration process to generate water, iodine, and gadolinium basis images. Quantitative material concentrations and image noise magnitudes, and noise power spectra (NPS) were measured. Results Iodine and gadolinium concentrations above 1.25 mg/ml were visible in the material basis images in all phantoms. Averaged quantitative accuracy for iodine and gadolinium in the small, large, and thorax phantoms were 0.39 ± 0.30 mg/ml, 0.96 ± 0.53 mg/ml, and 0.53 ± 0.35 mg/ml, respectively. In the water basis images, accuracy was within 24 HU in all phantoms. Noise magnitudes in iodine and gadolinium basis images were 2.91 and 3.52 times that of the lowest energy threshold image for the small phantom, and were 6.92 and 7.17 times that of the lowest threshold image for the large phantom. Noise texture did not change between the energy threshold and material basis images for either size phantom as measured by the NPS. Conclusions After a comprehensive system calibration, a commercial PCD‐CT with four energy thresholds performed multiple material decomposition of iodine, gadolinium, and water for concentrations above 1.25 mg/ml in human‐sized phantoms. Noise amplification and quantitative accuracy from the decomposition greatly depended on object size.
Diagnosis, Prognosis, and Drug Target Discovery for Chronic Widespread Pain: A Large Proteogenomic Study
Meng, Ruogu , Liu, Duanke, Guo, Yuchen, Wang, Yunhe, Gao, Yaqing , Huang, Zhe , Zhu, Liang , Zeng, Chao , Ma, Jun , Irani, Anushka, Lei, Guanghua, Irani, Anushka , Chen, Li , Xie, Junqing , Irani, Anushka , Kelleher, Eoin , Guo, Yuchen, Wang, Yunhe, Yuan, Shuai , Dong, Yanhui, Lei, Guanghua, Prieto‐Alhambra, Daniel

Advanced Science | September 30, 2025 | Volume: 12 | Issue: 47 | Pages: No page available

10.1002/advs.202507691 | PMID 41025730 Get It

Abstract Chronic widespread pain (CWP) remains challenging due to its heterogeneous causes and complex mechanisms. A total of 2920 plasma proteins are analyzed from 29,254 UK Biobank participants. A total of 256 proteins are identified as cross‐sectionally correlated with CWP. A simple (top 10 proteins) and comprehensive (all significant proteins) proteomic‐based score (ProtS) is created for CWP diagnosis, both outperforming and improving the existing clinical score (area under the curve, AUC: 0.801, 0.723, and 0.791 alone, and 0.856 and 0.880 in combination). In addition, the protein score predicted 13‐years risk of pain‐related traits over the body, including pain onset, progression, and intensity; Moreover, it has stronger associations with nociplastic pain and fibromyalgia compared to nociceptive and neuropathic pain, implying a unique protein signature of different pain mechanisms. Finally, among 434 candidate proteins prioritized in the observational analysis, 18 are corroborated with causal relevance by Mendelian randomization, and importantly, four (CA14, DPEP1, LGALS3, and TNF) showed potential as novel drug targets repurposed for treating CWP.
Prospective comparison of ultra-high-resolution photon-counting detector CT coronary angiography versus conventional CT
McCollough, Cynthia H. , Davis, Ann A., Weber, Nikkole M. , Kasten, Holly J., Melka, Elnata F., Rajendran, Kishore , Leng, Shuai , Davis, Aeden K, Leng, Shuai , McCollough, Cynthia H , Rajendran, Kishore , Carter, Rickey E.

British Journal of Radiology | September 5, 2025 | Volume: 99 | Issue: 1177 | Pages: 73-82

10.1093/bjr/tqaf220 | PMID 40911287 Get It

Abstract Objectives Determine differences in quantitative stenosis severity measurements for ultra-high-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (cCTA) relative to energy-integrating detector (EID) cCTA in a large patient cohort. Methods Adult participants seen between November 2022 and March 2023 underwent a clinical dual-source EID-CT cCTA and a research dual-source PCD-CT cCTA on the same day. Percent diameter stenosis (PDS) was measured, and stenosis severity was assigned based on the PDS of the most severe lesion per patient to determine a coronary artery disease reporting and data system (CAD-RADS) score. Agreement between EID-CT and PCD-CT for PDS and CAD-RADS was determined. Results A total of 112 participants were enrolled, yielding 82 subjects with at least 1 stenosis at PCD-CT (mean age, 68.0 ± 10.8 years; 69.5% [57/82] males). A total of 177 paired stenoses were quantified. The percent decrease in mean PDS from PCD-CT (24.3%) to EID-CT (29.4%) was 17.3% (median difference in PDS: −5.0%, 95% CI: −5.7% to −4.0%). The assigned CAD-RADS score changed in 31/82 subjects. In 11/31 subjects, the most severe stenosis was missed at EID-CT due to partial volume averaging of a small calcification, yet PCD clearly identified stenosis at those locations. In 20/31 subjects, the CAD-RADS score decreased at PCD-CT due to the decreased calcium blooming resulting from the improved spatial resolution. Conclusions UHR PCD cCTA decreases quantitative measures of stenosis severity when a stenosis is identified at EID, leading to decreases in CAD-RADS assignments. Advances in knowledge With its improved spatial resolution, PCD-CT identifies stenoses missed on EID-CT.
Four-Dimensional Computed Tomography-Derived Radiolunate Arthrokinematics With a Case Study in Four-Corner Arthrodesis
Trentadue, Taylor P. , Thoreson, Andrew R. , Lopez, Cesar , Leng, Shuai, Amadio, Peter C. , Kakar, Sanjeev , Zhao, Kristin D. , Amadio, Peter, Kakar, Sanjeev , Trentadue, Taylor P , Trentadue, Taylor P , Leng, Shuai

HAND | August 7, 2025 | Volume: 21 | Issue: 8 | Pages: 1286-1296

10.1177/15589447251352124 | PMID 40770847 Get It

Background: The radiolunate joint is conventionally thought to be spared from radiocarpal osteoarthritis, but proximal lunate degenerative changes have been noted. An investigation of radiolunate arthrokinematics in ostensibly healthy wrists may improve understanding of posttraumatic and postoperative outcomes. We hypothesize that four-dimensional computed tomography (4DCT)-derived radiolunate arthrokinematics during motion will differ between wrists with type 1 and type 2 lunates. The clinical-translational relevance of this analysis is highlighted using a 4DCT case study of scaphoid excision with 4-corner arthrodesis (SEFCA). Methods: Four-dimensional computed tomography data were collected during flexion-extension and radioulnar deviation in 19 healthy wrists (mean [SD] age: 43.6 [11.7] years, 21.1% female) and 1 wrist 3 years after SEFCA (male, 52 years). Carpal osteokinematics and joint arthrokinematics were calculated to derive median radiolunate interosseous proximities at each 4DCT-captured timepoint. Results: Median radiolunate interosseous proximities during motion are well approximated by second-order regressions in uninjured wrists. In the arthrodesed wrist, closest proximities occurred at the extremes of motion except maximum radial deviation. Conclusions: This study quantifies a normative range of median radiolunate interosseous proximities during wrist motion. The normative 4DCT datasets provide a reference range for evaluating postoperative arthrokinematics, suggesting the clinical-translational potential of dynamic imaging. The case study highlights applications for patient-level postoperative evaluation, which can be expanded to other pathologies, surgeries, or conditions in the future.
Preserving noise texture through training data curation for deep learning denoising of high‐resolution cardiac EID‐CT
Treb, Kevin , Chang, Shaojie , Koons, Emily K. , Marsh, Jeffrey F., Foley, Thomas A. , Williamson, Eric E. , Koons, Emily, Marsh, Jeffrey, Foley, Thomas , McCollough, Cynthia, Treb, Kevin , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | July 15, 2025 | Volume: 52 | Issue: 7 | Pages: No page available

10.1002/mp.17938 | PMID 40660962 Get It

Abstract Background To utilize high spatial resolution reconstructions for cardiac imaging at energy‐integrating detector CT (EID)‐CT with comparable noise to similar reconstructions at photon‐counting detector (PCD)‐CT, methods to control EID‐CT image noise are needed. Supervised convolutional neural networks (CNN) have shown promise for denoising, but a challenge remains to efficiently create high‐quality and unbiased estimates of noise without access to dedicated software or proprietary information, such that natural noise texture is retained in CNN‐denoised CT images. Purpose This study aims to develop and test image‐based noise estimation methods that can be used to train a CNN model, and to evaluate denoising performance and noise texture preservation for EID‐CT coronary CT angiography (cCTA) images reconstructed with high‐resolution kernels. Methods U‐net CNN models were trained for denoising. To supervise training, noise‐only images were estimated directly from high‐resolution kernel (Bv59) reconstructed EID‐CT (HR EID‐CT) patient images using two different methods: subtraction of low‐ and high‐strength iterative reconstruction (IR); subtraction of adjacent image slices with the same IR strength. The noise estimates from these methods contain differing noise texture and anatomical information. Networks were trained and validated separately for three data sets: the training data from each of the two noise‐estimation methods, and a 50%–50% partition of training data between the two methods. The trained models were applied to two sets of testing data: CT images of a uniform water phantom to measure noise power spectra (NPS), and an independent cohort of seven patient cCTA HR EID‐CT exams. The denoised patient images were compared to standard resolution EID‐CT reconstructions (Bv40). As a low‐noise reference, patient images acquired on the same day with a PCD‐CT and reconstructed using a similar kernel as HR EID‐CT were used for comparison. Results Models trained with each noise‐image estimation method denoised the HR EID‐CT images by 74%–79% to achieve a comparable noise magnitude to the HR PCD‐CT images. The peak, average, and 10% peak frequencies of the NPS of the input images (6.08, 6.24, and 12.0 cm −1 ) were better approximated by the model trained on adjacent slice subtraction (6.56, 5.87, and 11.5 cm −1 ) than by the model trained on subtraction of low‐ and high‐IR images (4.64, 5.44, and 11.3 cm −1 ). In cCTA images, the IR subtraction model images retained anatomic structures from input images but resulted in undesirable salt‐and‐pepper noise texture and CT number bias. The model trained on adjacent slice subtraction images had more natural texture and no significant bias, but the model sometimes removed small anatomic structures. The model trained on the mixed training dataset preserved both noise texture and anatomy from the model inputs and enabled visualization of small structures seen in PCD‐CT images that were previously unresolved by EID‐CT. Conclusions The noise texture and anatomical accuracy in CT images denoised with an image‐based supervised CNN are greatly influenced by the characteristics and partitioning of training data. With higher‐resolution reconstructions and noise texture‐preserving deep learning denoising, the quality of cCTA images from EID‐CT can be enhanced to enable resolvability of subtle anatomy similar to PCD‐CT.
Learned high resolution energy‐integrating detector CT angiography: Harnessing the power of ultra‐high‐resolution photon counting detector CT
Koons, Emily K. , Chang, Shaojie , Missert, Andrew D., Gong, Hao , Thorne, Jamison E. , Hoodeshenas, Safa , McCollough, C, Leng, Shuai, Rajiah, Prabhakar Shantha, Missert, Andrew D., Rajiah, Prabhakar , Leng, Shuai

Medical Physics | May 8, 2025 | Volume: 52 | Issue: 7 | Pages: No page available

10.1002/mp.17874 | PMID 40344194 Get It

Abstract Background Coronary computed tomography angiography (cCTA) is a widely used noninvasive diagnostic exam to assess patients for coronary artery disease (CAD). However, the spatial resolution of most CT scanners is limited due to the use of energy‐integrating detectors (EIDs). Purpose To develop a convolutional neural network ( I mproved LUMEN visualization through A rtificial super‐resolu T ion imag E s (ILUMENATE)) informed by photon‐counting‐detector (PCD)‐CT to improve EID‐CT image resolution and determine its impact on cCTA. Materials and methods With IRB approval, 30 patients undergoing clinically indicated cCTA were scanned with EID‐CT (SOMATOM Force, Siemens Healthineers, Forchheim, Germany) and subsequently with ultra‐high‐resolution (UHR) PCD‐CT (NAEOTOM Alpha, Siemens Healthineers) on the same day. ILUMENATE was trained on eight patient PCD‐CT datasets (67,890 patch pairs with 90% for training (61,101), 10% reserved for validation (6,789)) and applied to 22 unseen EID‐CT cases. Spatial resolution was evaluated using line profiles and percent diameter stenosis quantified with a severity score assigned. Two experienced radiologists, blinded to image type, selected preferred series and scored images for overall quality, sharpness, and noise comparing original EID‐CT and ILUMENATE output. Results Visual assessment and line profiles showed substantial resolution improvement with ILUMENATE. Percent diameter stenosis was significantly reduced (mean ± standard deviation: 4.42% ± 4.82%) using ILUMENATE ( p < 0.001) with nine lesions shifting down in severity score. Readers preferred ILUMENATE images in 22/22 cases and scored ILUMENATE superiorly for overall quality, sharpness, and noise ( p < 0.05). Conclusions ILUMENATE enhanced image resolution, resulting in improved overall image quality, reduced calcium blooming artifacts, and improved lumen visibility in cCTA exams performed using EID‐CT. This could potentially allow for improved accessibility to UHR image quality, allowing for more accurate assessment of CAD.
Quantitative CT imaging: where are we, and what is missing?
Treb, Kevin , Sadaney, Ahmed O El , Ferrero, Andrea , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Rajendran, Kishore , Treb, Kevin J, El Sadaney, Ahmed O , Leng, Shuai , Yu, Lifeng , Rajiah, Prabhakar Shantha, McCollough, Cynthia H , Rajendran, Kishore , Treb, Kevin , Baffour, Francis , Rajiah, Prabhakar , Fletcher, Joel G.

British Journal of Radiology | April 7, 2025 | Volume: 98 | Issue: 1175 | Pages: 1834-1842

10.1093/bjr/tqaf075 | PMID 40193477 Get It

Abstract Quantitative computed tomography (CT) enables the measurement of biophysical processes characterized by morphology, composition, flow, and/or motion to aid in clinical diagnosis and intervention. Since its initial application for determining bone mineral density for skeletal fragility assessment, quantitative CT has continued to evolve alongside CT’s technological advancements. A key challenge facing quantitative CT is the lack of standardization pertinent to image acquisition, reconstruction, and image analysis. With the introduction of spectral CT involving dual-energy approaches and photon-counting detectors (PCD), we are now able to obtain detailed information regarding mass densities of endogenous and exogeneous materials. Furthermore, energy-resolved CT yields spectral image types (eg, virtual monoenergetic image) that are, in principle, independent of tube potential and patient size. This paves the way for workflow standardization and helps improve the consistency and reproducibility of CT-derived measurements. In this article, we review clinical applications of quantitative CT, discuss key challenges associated with quantitative CT and its adoption into routine practice, and outline the unique benefits ushered by new CT technologies such as PCD-CT towards improving quantitative imaging.