Citations

Mayo Clinic

Clear

21 citation(s) found for "O’Neill, William".

Real world outcomes using 20 mm balloon expandable SAPIEN 3/ultra valves compared to larger valves (23, 26, and 29 mm)–a propensity matched analysis
Eng, Marvin H. , Abbas, Amr E. , Wang, Dee Dee , Eleid, Mackram F. , Wang, Dee Dee , Eleid, Mackram F , Hahn, Rebecca T , Lee, James , O’Neill, William W.

Catheterization and Cardiovascular Interventions | May 13, 2021 | Volume: 98 | Issue: 6 | Pages: 1185-1192

10.1002/ccd.29756 | PMID 33984182 Get It

AbstractObjective/BackgroundSmall balloon expandable valves have higher echocardiographic transvalvular gradients and rates of prosthesis‐patient mismatch (PPM) compared to larger valves. However, the impact of these echocardiographic findings on clinical outcomes is unknown. We sought to determine the clinical outcomes of 20 mm SAPIEN 3 (S3 BEV) compared to larger S3 BEV in relation to echocardiographic hemodynamics.MethodsUsing the STS/ACC transcatheter valve registry, we performed a propensity‐matched comparison of patients undergoing treatment of native aortic valve stenosis using transfemoral, balloon‐expandable implantation of 20 mm and ≥ 23 mm S3 BEVs. Baseline and procedure characteristics, echocardiographic variables and survival were analyzed. Multivariable logistic regression was used to identify predictors of 1‐year mortality.ResultsAfter propensity matching of the 20 mm and ≥ 23 mm SAPIEN 3 valves, 3,931 pairs with comparable baseline characteristics were identified. Small valves were associated with significantly higher echocardiographic gradients at discharge (15.7 ± 7.1 mmHg vs. 11.7 ± 5.5 mmHg, p < 0.0001) and severe PPM rates (21.5% vs. 9.7%, p < 0.0001). There was no significant difference in 1‐year all‐cause mortality (20 mm: 13.0% vs. ≥23 mm: 12.7%, p = 0.72) or other major adverse event rates and outcomes between the two cohorts. Based on a multivariable analysis, elevated discharge mean gradient (>20 mmHg), severe PPM and the use of 20 mm versus ≥23 mm were not independent predictors of 1‐year mortality.ConclusionSAPIEN 3 20 mm valves were associated with higher echocardiographic gradients, and severe PPM rates compared to larger valves but these factors were not associated with significant differences in 1‐year all‐cause mortality or rehospitalization.
Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Vemulapalli, Sreekanth , Xiang, Qun, Wang, Dee Dee , Eleid, Mackram F. , Sandhu, Gurpreet S. , Salinger, Michael H., Russell, Hyde M., Kodali, Susheel , Dvir, Danny , Russo, Mark J., Fang, Kenith, Coylewright, Megan , Shah, Pinak , Babaliaros, Vasilis , Khan, Jaffar M. , Tommaso, Carl L. , Saucedo, Jorge , Makkar, Rajj, Mack, Michael J. , Holmes, David R. , Leon, Martin B. , Bapat, Vinayak , Thourani, Vinod H. , Rihal, Charanjit S. , O’Neill, William, Feldman, Ted , Douglas, Pamela S. , Eleid, Mackram, Cabalka, Allison K. , Rihal, Charanjit, Wang, Dee Dee , Douglas, Pamela S , Guerrero, Mayra , Greenbaum, Adam B. , George, Isaac , Whisenant, Brian K. , Pershad, Ashish , Shah, Pinak , Kar, Saibal , Makkar, Raj , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | March 6, 2020 | Volume: 13 | Issue: 3 | Pages: No page available

10.1161/circinterventions.119.008425 | PMID 32138529 Get It

Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.
Complete percutaneous apical access and closure: Short and intermediate term outcomes
Eng, Marvin H. , Kherallah, Riyad , Guerrero, Mayra , Frisoli, Tiberio , Villablanca, Pedro , Wang, Dee Dee , Wyman, Janet , Wang, Dee Dee , Guerrero, Mayra E , Greenbaum, Adam B. , Lee, James , O’Neill, William W.

Catheterization and Cardiovascular Interventions | January 20, 2020 | Volume: 96 | Issue: 2 | Pages: 481-487

10.1002/ccd.28731 | PMID 31957915 Get It

AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Wood, David , Krajcer, Zvonimir , Sathananthan, Janarthanan , Strickman, Neil E., Metzger, Chris, Fearon, William F. , Aziz, Mark, Satler, Lowell F. , Waksman, Ron , Eng, Marvin H. , Heimansohn, David, Sampson, Andrew, Coady, Paul , Rodriguez, Roberto , Krishnaswamy, Amar , Lee, Jason T. , Ben‐Dor, Itsik , Moainie, Sina L. , Kodali, Susheel , Yadav, Pradeep , Kozak, Mark, Bacharach, J. Michael, Feldman, Ted , Nanjundappa, Aravinda , Bersin, Robert M., Potluri, Srinivasa , Barker, Colin M. , Bernardo, Nelson L. , Lumsden, Alan B. , Dake, Michael D. , Brown, David L. , Maor, Nathaniel, Nardone, Samuel, Webb, John G. , Investigators, on behalf of the SAFE MANTA Study, Kapadia, Samir , Greenbaum, Adam B. , Szerlip, Molly , Chhatriwalla, Adnan K , O’Neill, Brian Patrick , Guerrero, Mayra , Zhang, Ming , Barleben, Andrew R. , Campbell, John , Cohen, David Jonathan , Lauck, Sandra , O’Neill, William W. , Investigators, on behalf of the SAFE MANTA Study

Circulation: Cardiovascular Interventions | July 12, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007258 | PMID 31296082 Get It

Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
Association of peripheral artery disease with in‐hospital outcomes after endovascular transcatheter aortic valve replacement
Mohananey, Divyanshu , Villablanca, Pedro , Ando, Tomo , Wang, Dee Dee , Wiley, José , Eng, Marvin H. , Shah, Binita , Saucedo, Jorge , Bhatt, Deepak L. , Ando, Tomo , Wang, Dee Dee , Eng, Marvin , Ramakrishna, Harish , Bhatt, Deepak L , Shah, Binita , Gupta, Tanush , Ranka, Sagar , Bhatia, Nirmanmoh , Adegbala, Oluwole Muyiwa , Kalra, Ankur , O’Neill, William W.

Catheterization and Cardiovascular Interventions | April 26, 2019 | Volume: 94 | Issue: 2 | Pages: 249-255

10.1002/ccd.28310 | PMID 31025488 Get It

AbstractObjectivesThe aim of this study was to determine the prevalence of peripheral artery disease (PAD) and its association with in‐hospital outcomes after endovascular transcatheter aortic valve replacement (EV‐TAVR).BackgroundTAVR is an established treatment for patients at prohibitive, high, or intermediate surgical risk. PAD is a significant comorbidity in the determination of surgical risk. However, data on association of PAD with outcomes after EV‐TAVR are limited.MethodsPatients in the National Inpatient Sample who underwent EV‐TAVR between January 1, 2012 and September 30, 2015 were evaluated. The primary outcome was in‐hospital mortality.ResultsA total of 51,685 patients underwent EV‐TAVR during the study period. Of these, 12,740 (24.6%) had a coexisting diagnosis of PAD. The adjusted odds for in‐hospital mortality [OR 1.08 (95% CI 0.83–1.41)], permanent pacemaker implantation [OR 0.98 (0.85–1.14)], conversion to open aortic valve replacement [OR 1.05 (0.49–2.26)], or acute myocardial infarction [OR 1.31(0.99–1.71)] were not different in patients with versus without PAD. However, patients with PAD had greater adjusted odds of vascular complications [OR 1.80 (1.50–2.16)], major bleeding [OR 1.20 (1.09–1.34)], acute kidney injury (AKI) [OR 1.19 (1.05–1.36)], cardiac complications [aOR 1.21 (1.01–1.44)], and stroke [OR 1.39(1.10–1.75)] compared with patients without PAD. Length of stay (LOS) was significantly longer for patients with PAD [7.23 (0.14) days vs. 7.11 (0.1) days, p < 0.001].ConclusionOf patients undergoing EV‐TAVR, ~25% have coexisting PAD. PAD was not associated with increased risk of in‐hospital mortality but was associated with higher risk of vascular complications, major bleeding, AKI, stroke, cardiac complications, and longer LOS.
Temporal trends of survival and utilization of mechanical circulatory support devices in patients with in‐hospital cardiac arrest secondary to ventricular tachycardia/ventricular fibrillation
Patel, Nileshkumar, Kumar, Varun , Panakos, Andrew, Narayanan, Mahesh Anantha , Bhardwaj, Bhaskar , Arora, Shilpkumar , Deshmukh, Abhishek , Patel, Nileshkumar , Basir, Mir B. , Cohen, Mauricio G. , Kini, Annapoorna , Sharma, Samin K. , Dangas, George , O’Neill, William W. , Alfonso, Carlos E., Patel, Nileshkumar J , Atti, Varunsiri , Kumar, Varun , Anantha Narayanan, Mahesh , Patel, Nish , Basir, Mir B , Cohen, Mauricio G , Kini, Annapoorna S , Sharma, Samin K , Dangas, George

Catheterization and Cardiovascular Interventions | February 21, 2019 | Volume: 94 | Issue: 4 | Pages: 578-587

10.1002/ccd.28138 | PMID 30790415 Get It

AbstractBackgroundPulseless ventricular tachycardia/ventricular fibrillation (VT/VF) is the initial rhythm in a third of in‐hospital cardiac arrest patients. Mechanical circulatory support (MCS) device use remains poorly understood in this population.MethodsWe conducted an observational analysis of temporal trends in the utilization of MCS in VT/VF IHCA between January 2008 and December 2014 utilizing the Nationwide Inpatient Sample (NIS) database. Using multivariable analysis, we assessed factors associated with MCS use and survival to discharge.ResultsAmong 151,628 hospitalizations with VT/VF IHCA, 14,981 (9.9%) received MCS. Intra‐aortic balloon pump (IABP) was the most commonly used MCS (9.1%). From 2008 to 2014, there was significant increase in the utilization of MCS (8.7–11%; ptrend < 0.0001). On multivariable analysis, there was 12‐fold increase and three‐fold increase in the utilization of PVAD and ECMO respectively; however, there was no significant change in the use of IABP. Over the seven‐year sample period, there was significant increase in the overall survival to hospital discharge (35.4–43.5%; ptrend < 0.0001). Survival to hospital discharge increased in both MCS and non‐MCS groups.ConclusionThere was significant increase in utilization of MCS after VT/VF IHCA during the study period. IABP was the most commonly utilized MCS. The survival to hospital discharge increased in the overall study population including both MCS and non‐MCS groups. Future studies are needed to identify patient population most likely to benefit from the use of MCS after VT/VF IHCA.
Double-Blind Phase III Trial of Adjuvant Chemotherapy With and Without Bevacizumab in Patients With Lymph Node–Positive and High-Risk Lymph Node–Negative Breast Cancer (E5103)
O’Neill, Anne, Gradishar, William J. , Hobday, Timothy J. , Goldstein, Lori J. , Bloom, Stuart H. , Brufsky, Adam , Sparano, Joseph A. , Le‐Lindqwister, Nguyet, Hendricks, Carolyn B., Northfelt, Donald W. , Dang, Chau T. , O'Neill, Anne, Gradishar, William, Mayer, Ingrid A. , Bloom, Stuart , Brufsky, Adam M., Le-Lindqwister, Nguyet Anh, Brufsky, Adam M , Sparano, Joseph A , Miller, Kathy D. , Tevaarwerk, Amyé , Sledge, George W.

Journal of Clinical Oncology | July 24, 2018 | Volume: 36 | Issue: 25 | Pages: 2621-2629

10.1200/jco.2018.79.2028 | PMID 30040523 Get It

PurposeBevacizumab improves progression-free survival but not overall survival in patients with metastatic breast cancer. E5103 tested the effect of bevacizumab in the adjuvant setting in patients with human epidermal growth factor receptor 2–negative disease.Patients and MethodsPatients were assigned 1:2:2 to receive placebo with doxorubicin and cyclophosphamide (AC) followed by weekly paclitaxel (arm A), bevacizumab only during AC and paclitaxel (arm B), or bevacizumab during AC and paclitaxel followed by bevacizumab monotherapy for 10 cycles (arm C). Random assignment was stratified and bevacizumab dose adjusted for choice of AC schedule. Radiation and hormonal therapy were administered concurrently with bevacizumab in arm C. The primary end point was invasive disease–free survival (IDFS).ResultsFour thousand nine hundred ninety-four patients were enrolled. Median age was 52 years; 64% of patients were estrogen receptor positive, 27% were lymph node negative, and 78% received dose-dense AC. Chemotherapy-associated adverse events including myelosuppression and neuropathy were similar across all arms. Grade ≥ 3 hypertension was more common in bevacizumab-treated patients, but thrombosis, proteinuria, and hemorrhage were not. The cumulative incidence of clinical congestive heart failure at 15 months was 1.0%, 1.9%, and 3.0% in arms A, B, and C, respectively. Bevacizumab exposure was less than anticipated, with approximately 24% of patients in arm B and approximately 55% of patients in arm C discontinuing bevacizumab before completing planned therapy. Five-year IDFS was 77% (95% CI, 71% to 81%) in arm A, 76% (95% CI, 72% to 80%) in arm B, and 80% (95% CI, 77% to 83%) in arm C.ConclusionIncorporation of bevacizumab into sequential anthracycline- and taxane-containing adjuvant therapy does not improve IDFS or overall survival in patients with high-risk human epidermal growth factor receptor 2–negative breast cancer. Longer duration bevacizumab therapy is unlikely to be feasible given the high rate of early discontinuation.
Influence of hospital volume on outcomes of percutaneous atrial septal defect and patent foramen ovale closure: A 10‐years us perspective
Singh, Vikas , Badheka, Apurva O., Patel, Nileshkumar, Chothani, Ankit , Mehta, Kathan , Arora, Shilpkumar , Patel, Nilay , Deshmukh, Abhishek , Shah, Neeraj , Savani, Ghanshyambhai T., Manvar, Sohilkumar, Thakkar, Badal, Panchal, Vinaykumar , Palacios, Igor F. , Rihal, Charanjit S. , Cohen, Mauricio G. , Marchena, Eduardo de , Rathod, Ankit D. , Patel, Jay N. , Rihal, Charanjit S. , O’Neill, William W. , Cohen, Mauricio G

Catheterization and Cardiovascular Interventions | December 22, 2014 | Volume: 85 | Issue: 6 | Pages: 1073-1081

10.1002/ccd.25794 | PMID 25534392 Get It

Background: Contemporary data regarding percutaneous closure of atrial septal defect/patent foramen ovale (ASD/PFO) are lacking. We evaluated the current trends in utilization of ASD/PFO closure in adults and investigated the effect of annual hospital volume on in‐hospital outcomes. Methods: We queried the Nationwide Inpatient Sample between the years 2001 and 2010 using the International Classification of Diseases (ICD‐9‐CM) procedure code for percutaneous closure of ASD/PFO with device. Hierarchical mixed effects models were generated to identify the independent multivariate predictors of outcomes. Results: A total of 7,107 percutaneous ASD/PFO closure procedures (weighted n = 34,992) were available for analysis. A 4.7‐fold increase in the utilization of this procedure from 3/million in 2001 to 14/million adults in 2010 in US (P < 0.001) was noted. Overall, percutaneous ASD/PFO closure was associated with 0.5% mortality and 12% in‐hospital complications. The utilization of intracardiac echocardiography (ICE) increased 15 fold (P < 0.001) during the study period. The procedures performed at the high volume hospitals [2nd (14–37 procedures/year) and 3rd (>38 procedures/year) tertile] were associated with significant reduction in complications, length of stay and cost of hospitalization when compared to those performed at lowest volume centers (<13 procedures/year). Majority (70.5%) of the studied hospitals were found to be performing <10 procedures/year hence deviating from the ACC/AHA/SCAI clinical competency guidelines. Conclusions: Low hospital volume is associated with an increased composite (mortality and procedural complications) adverse outcome following ASD/PFO closure. In the interest of patient safety, implementation of the current guidelines for minimum required annual hospital volume to improve clinical outcomes is warranted. © 2014 Wiley Periodicals, Inc.
The Current Use of Impella 2.5 in Acute Myocardial Infarction Complicated by Cardiogenic Shock: Results from the USpella Registry
O’Neill, William W. , Schreiber, Theodore , Wohns, David , Rihal, Charanjit S. , Naidu, Srihari S. , Civitello, Andrew B. , Dixon, Simon , Maini, Brijeshwar , Ohman, E. Magnus , Rihal, Charanjit S. , Massaro, Joseph M.

Journal of Interventional Cardiology | December 13, 2013 | Volume: 27 | Issue: 1 | Pages: 1-11

10.1111/joic.12080 | PMID 24329756 Get It

Abstract Objectives To evaluate the periprocedural characteristics and outcomes of patients supported with Impella 2.5 prior to percutaneous coronary intervention (pre‐PCI) versus those who received it after PCI (post‐PCI) in the setting of cardiogenic shock (CS) complicating an acute myocardial infarction (AMI). Background Early mechanical circulatory support may improve outcome in the setting of CS complicating an AMI. However, the optimal timing to initiate hemodynamic support has not been well characterized. Methods Data from 154 consecutive patients who underwent PCI and Impella 2.5 support from 38 US hospitals participating in the USpella Registry were included in our study. The primary end‐point was survival to discharge. Secondary end‐points included assessment of patients' hemodynamics and in‐hospital complications. A multivariate regression model was used to identify independent predictors for mortality. Results Both groups were comparable except for diabetes (P = 0.02), peripheral vascular disease (P = 0.008), chronic obstructive pulmonary disease (P = 0.05), and prior stroke (P = 0.04), all of which were more prevalent in the pre‐PCI group. Patients in the pre‐PCI group had more lesions (P = 0.006) and vessels (P = 0.01) treated. These patients had also significantly better survival to discharge compared to patients in the post‐PCI group (65.1% vs.40.7%, P = 0.003). Survival remained favorable for the pre‐PCI group after adjusting for potential confounding variables. Initiation of support prior to PCI with Impella 2.5 was an independent predictor of in‐hospital survival (Odds ratio 0.37, 95% confidence interval: 0.17–0.79, P = 0.01) in multivariate analysis. The incidence of in‐hospital complications included in the secondary end‐point was similar between the 2 groups. Conclusions The results of our study suggest that early initiation of hemodynamic support prior to PCI with Impella 2.5 is associated with more complete revascularization and improved survival in the setting of refractory CS complicating an AMI. (J Interven Cardiol 2014;27:1–11)