Citations

Mayo Clinic

Clear

23 citation(s) found for "Nair, Devi".

The impact of pulmonary hypertension on outcomes of transcatheter mitral valve replacement in mitral annular calcification
Cajigas, Héctor , Kaptzan, Tatiana, Lewis, Bradley R., El‐Sabbagh, Abdallah, Al‐Hijji, Mohammed , Eleid, Mackram F. , Wang, Dee Dee , Eng, Marvin H. , Kodali, Susheel , Chakravarty, Tarun , O’Hair, Daniel, Jones, Noah, Makkar, Raj , Reisman, Mark, Leon, Martin B. , Rihal, Charanjit S. , Cajigas, Hector R , Eleid, Mackram F , Wang, Dee Dee , Pershad, Ashish , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Alkhouli, Mohamad , George, Isaac , Pershad, Ashish , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Catheterization and Cardiovascular Interventions | January 12, 2022 | Volume: 99 | Issue: 5 | Pages: 1647-1658

10.1002/ccd.30057 | PMID 35019204 Get It

AbstractObjectivesTo assess the impact of pulmonary hypertension (PH) on outcomes of patients with severe mitral annular calcification (MAC) undergoing transcatheter mitral valve replacement (TMVR).BackgroundPH is associated with poor outcomes after mitral valve surgery. Whether the presence of PH in patients with MAC undergoing (TMVR) is associated with poor outcomes, is unknown.MethodsRetrospective evaluation of 116 patients from 51 centers in 11 countries who underwent TMVR with valve in mitral annular calcification (ViMAC) using balloon‐expandable aortic transcatheter valves (THVs) from September 2012 to March 2017. Pulmonary artery systolic blood pressure (PASP) by echocardiogram was available in 90 patients. The subjects were stratified based on PASP: No PH = PASP ≤35 mmHg (n = 11); mild to moderate PH = PASP 36–49 mmHg (n = 21) and severe PH = PASP ≥50 mmHg (n = 58). Clinical, procedural, and echocardiographic outcomes were assessed.ResultsMean age was 72.7 (±12.8) years, 59 (65.6%) were female, Society of Thoracic Surgeons score was 15.8 + 11.8% and 90.0% where in New York Heart Association (NYHA) class III–IV. There was no significant difference in all‐cause mortality at 30 days (no PH = 27.3%, mild–moderate PH = 19.0%, severe PH = 31.6%; p = 0.55) or at 1 year (no PH = 54.5%, mild–moderate PH = 38.1%, severe PH = 56.1%; p = 0.36). No difference in adverse events, NYHA class or amount of residual mitral regurgitation at 1 year were observed between the groups.ConclusionThis study suggests that the presence of PH in patients with predominantly mitral stenosis with MAC undergoing TMVR does not impact mortality or adverse events. Further studies are needed to fully understand the effect of PH in this group of patients.
Sex-Based Differences in Outcomes With Percutaneous Transcatheter Repair of Mitral Regurgitation With the MitraClip System: Transcatheter Valve Therapy Registry From 2011 to 2017
Villablanca, Pedro , Vemulapalli, Sreekanth , Stebbins, Amanda , Dai, Dadi, So, Chak-Yu , Eng, Marvin H. , Wang, Dee Dee , Frisoli, Tiberio , Lee, James , Kang, Guson , Ibrahim, Homam , Staniloae, Cezar , Gaba, Prakriti , Lemor, Alejandro , Finn, Matthew , Leon, Martin B. , Villablanca, Pedro A , Lee, James C , Staniloae, Cezar , Lemor, Alejandro , Ramakrishna, Harish , Shah, Binita , Wang, Dee Dee , Szerlip, Molly , Williams, Mathew , O’Neill, William W. , Shah, Binita

Circulation: Cardiovascular Interventions | November 16, 2021 | Volume: 14 | Issue: 11 | Pages: No page available

10.1161/circinterventions.120.009374 | PMID 34784236 Get It

Background: Women have a higher rate of adverse events after mitral valve surgery. We sought to evaluate whether outcomes after transcatheter edge-to-edge repair intervention by sex have similar trends to mitral valve surgery. Methods: The primary outcome was 1-year major adverse events defined as a composite of all-cause mortality, stroke, and any bleeding in the overall study cohort. Patients who underwent transcatheter edge-to-edge repair for mitral regurgitation with the MitraClip system in the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy registry were evaluated. Linked administrative claims from the Centers for Medicare and Medicaid Services were used to evaluate 1-year clinical outcomes. Associations between sex and outcomes were evaluated using a multivariable logistic regression model for in-hospital outcomes and Cox model for 1-year outcomes. Results: From November 2013 to March 2017, 5295 patients, 47.6% (n=2523) of whom were female, underwent transcatheter edge-to-edge repair. Females were less likely to have >1 clip implanted ( P <0.001) and had a lower adjusted odds ratio of device success (adjusted odds ratio, 0.78 [95% CI, 0.67–0.90]), driven by lower odds of residual mitral gradient <5 mm Hg (adjusted odds ratio, 0.54 [CI, 0.46–0.63]) when compared with males. At 1-year follow-up, the primary outcome did not differ by sex. Female sex was associated with lower adjusted 1-year risk of all-cause mortality (adjusted hazard ratio, 0.80 [CI, 0.68–0.94]), but the adjusted 1-year risk of stroke and any bleeding did not differ by sex. Conclusions: No difference in composite outcome of all-cause mortality, stroke, and any bleeding was observed between females and males. Adjusted 1-year all-cause mortality was lower in females compared with males.
Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry
Sabbagh, Abdallah El , Al‐Hijji, Mohammed , Wang, Dee Dee , Eleid, Mackram F. , Ureña, Marina , Himbert, Dominique , Chakravarty, Tarun , Fang, Hao , Zahr, Firas , Dvir, Danny , Sardar, Muhammad , Cheema, Asim N. , Alnasser, Sami , Iyer, Vijay , Kaddissi, Georges, Webb, John G. , Makkar, Raj , Vahanian, Alec , Rihal, Charanjit S. , Eleid, Mackram F , Nejjari, Mohammed , Dvir, Danny , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Wang, Dee Dee , Holzhey, David Michael , Pershad, Ashish , Nejjari, Mohammed , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation: Cardiovascular Interventions | October 19, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.010854 | PMID 34665654 Get It

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
Abstract 6023: The Need for Blood Transfusion Is an Independent Predictor of Incident Cardiovascular Events and All-Cause Mortality among Patients Undergoing Percutaneous Coronary Intervention
Mercado, Nestor, Dixon, Simon, Lamos, Pedro, Guarneri, Mimi, Terstein, Paul, Wijns, Williom, Boersma, Eric , Brugts, Jasper Jan , Ix, Joachim H. , Shlipak, Michael G. , Gersh, Bernard J. , O’Neill, William W.

Circulation | July 3, 2021 | Volume: 118 | Issue: suppl_18 | Pages: No page available

10.1161/circ.118.suppl_18.s_1049-a Get It

Periprocedural bleeding is one of the most frequent complications of percutaneours coronary interventions. We assessed the relation between blood transfusion and all-cause mortality or incident cardiovascular events (death, MI, stroke) among 6103 patients of the Evaluation of Oral Xemilofiban in Controlling Thrombotic Events (EXCITE)-trial. Subjects were followed for 7 months after enrollment for the occurrence of events. Multivariate Cox-regression analysis evaluated the independent association of blood transfusion with each outcome adjusted for age, gender, race, diabetes mellitus, hypertension, hypercholesterolemia, history of MI, PCI, CABG, heart failure, LVEF<30%, use of beta-blockers, statins, ACE-inhibitors, platelet inhibitors and allocation to treatment with xemolifiban. In addition, propensity score analyses were performed (ROC 0.80). Mean age was 59.2 years, 21.7% were female, and 18.9% had diabetes mellitus. Of the169 patients who received blood transfusion, 14 (8.3%) died and 42 (24.9%) experienced a CVD event. Of the 5934 patients without transfusion, 65 (1.1%) died (p-value: <0.001) and 555 (9,4%) experienced a CVD event (p-value: <0.001) In multivariate analysis, blood transfusion was associated with a 5.3 fold increased risk of mortality (HR 5.3; 95% CI 2.8 –10.2), and a 2.5 fold increased risk of incident CVD (HR 2.5; 95% CI 1.7–3.4.) Noteworthy, patients who were US citizens had a higher transfusion rate then non-US citizens (OR 1.45, 95%CI 1.02–2.06) The need of blood transfusion is a strong and independent predictor of all-cause mortality and incident CVD events among patients undergoing PCI.
Short‐ and mid‐term outcomes in percutaneous mitral valve replacement using balloon expandable valves
Eng, Marvin H. , Kargoli, Faraj , Wang, Dee Dee , Frisoli, Tiberio , Villablanca, Pedro, Nemeh, Hassan, Guerrero, Mayra , O’Neill, Brian , Wyman, Janet , Guerrero, Mayra E , O'Neill, Brian P , Wang, Dee Dee , Lee, James C. , Villablanca, Pedro, Greenbaum, Adam B. , O’Neill, William W.

Catheterization and Cardiovascular Interventions | June 9, 2021 | Volume: 98 | Issue: 6 | Pages: 1193-1203

10.1002/ccd.29783 | PMID 34106514 Get It

AbstractBackgroundDue to elevated surgical risk, transcatheter mitral valve replacement (TMVR) is used as an alternative for treating failed bioprosthetic valves, annuloplasty repairs and mitral annular calcification (MAC). We report the procedural and longitudinal outcomes for each subtype: Mitral valve‐in‐valve (MVIV), mitral valve‐in‐ring (MViR), and valve‐in‐MAC (ViMAC).MethodsConsecutive patients undergoing TMVR from October 2013 to December 2019 were assessed. Patients at high risk for left ventricular outflow tract obstruction had either alcohol septal ablation or intentional laceration of the anterior leaflet (LAMPOON).ResultsEight‐eight patients underwent TMVR; 38 MViV, 31 MViR, and 19 ViMAC procedures were performed. The median Society of Thoracic Surgery 30‐day predicted risk of mortality was 8.2% (IQR 5.2, 19.9) for all. Sapien 3 (78%) and transseptal access (98%) were utilized in most cases. All‐cause in‐hospital mortality, technical, and procedural success were 8%, 83%, and 66% respectively. Median follow up was 1.4 years (IQR 0.5–2.9 years) and overall survival was 40% at 4 years. Differential survival rates were observed with MViV doing the best, followed by MViR and ViMAC having a <20% survival at 4 years. After adjusting for co‐variates, MViV procedure was the strongest predictor of survival (HR 0.24 [95% CI 0.079–0.7]).ConclusionTMVR is performed in at high‐risk patients with attenuated long‐term survival. MViV has the best success and survival rate, but long‐term survival in MViR and ViMAC is guarded.
Real world outcomes using 20 mm balloon expandable SAPIEN 3/ultra valves compared to larger valves (23, 26, and 29 mm)–a propensity matched analysis
Eng, Marvin H. , Abbas, Amr E. , Wang, Dee Dee , Eleid, Mackram F. , Wang, Dee Dee , Eleid, Mackram F , Hahn, Rebecca T , Lee, James , O’Neill, William W.

Catheterization and Cardiovascular Interventions | May 13, 2021 | Volume: 98 | Issue: 6 | Pages: 1185-1192

10.1002/ccd.29756 | PMID 33984182 Get It

AbstractObjective/BackgroundSmall balloon expandable valves have higher echocardiographic transvalvular gradients and rates of prosthesis‐patient mismatch (PPM) compared to larger valves. However, the impact of these echocardiographic findings on clinical outcomes is unknown. We sought to determine the clinical outcomes of 20 mm SAPIEN 3 (S3 BEV) compared to larger S3 BEV in relation to echocardiographic hemodynamics.MethodsUsing the STS/ACC transcatheter valve registry, we performed a propensity‐matched comparison of patients undergoing treatment of native aortic valve stenosis using transfemoral, balloon‐expandable implantation of 20 mm and ≥ 23 mm S3 BEVs. Baseline and procedure characteristics, echocardiographic variables and survival were analyzed. Multivariable logistic regression was used to identify predictors of 1‐year mortality.ResultsAfter propensity matching of the 20 mm and ≥ 23 mm SAPIEN 3 valves, 3,931 pairs with comparable baseline characteristics were identified. Small valves were associated with significantly higher echocardiographic gradients at discharge (15.7 ± 7.1 mmHg vs. 11.7 ± 5.5 mmHg, p < 0.0001) and severe PPM rates (21.5% vs. 9.7%, p < 0.0001). There was no significant difference in 1‐year all‐cause mortality (20 mm: 13.0% vs. ≥23 mm: 12.7%, p = 0.72) or other major adverse event rates and outcomes between the two cohorts. Based on a multivariable analysis, elevated discharge mean gradient (>20 mmHg), severe PPM and the use of 20 mm versus ≥23 mm were not independent predictors of 1‐year mortality.ConclusionSAPIEN 3 20 mm valves were associated with higher echocardiographic gradients, and severe PPM rates compared to larger valves but these factors were not associated with significant differences in 1‐year all‐cause mortality or rehospitalization.
Primary Outcome Evaluation of a Next-Generation Left Atrial Appendage Closure Device
Kar, Saibal , Doshi, Shephal K. , Sadhu, Ashish, Horton, Rodney , Osorio, José , Stone, James, Shah, Manish H. , Dukkipati, Srinivas R. , Adler, Stuart W., Kim, Jamie , Wazni, Oussama M. , Price, Mathew J., Holmes, David R. , Shipley, Robert D., Gordon, Nicole, Allocco, Dominic J. , Investigators, On behalf of the PINNACLE FLX, Kar, Saibal , Ellis, Christopher R. , Nair, Devi G , Asch, Federico M. , Reddy, Vivek Y. , Investigators, On behalf of the PINNACLE FLX

Circulation | April 6, 2021 | Volume: 143 | Issue: 18 | Pages: 1754-1762

10.1161/circulationaha.120.050117 | PMID 33820423 Get It

Background: Left atrial appendage (LAA) occlusion provides an alternative to oral anticoagulation for thromboembolic risk reduction in patients with nonvalvular atrial fibrillation. Since regulatory approval in 2015, the WATCHMAN device has been the only LAA closure device available for clinical use in the United States. The PINNACLE FLX study (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the Watchman FLX LAA Closure Technology) evaluated the safety and effectiveness of the next-generation WATCHMAN FLX LAA closure device in patients with nonvalvular atrial fibrillation in whom oral anticoagulation is indicated, but who have an appropriate rationale to seek a nonpharmaceutical alternative. Methods: This was a prospective, nonrandomized, multicenter US Food and Drug Administration study. The primary safety end point was the occurrence of one of the following events within 7 days after the procedure or by hospital discharge, whichever was later: death, ischemic stroke, systemic embolism, or device- or procedure-related events requiring cardiac surgery. The primary effectiveness end point was the incidence of effective LAA closure (peri-device flow ≤5 mm), as assessed by the echocardiography core laboratory at 12-month follow-up. Results: A total of 400 patients were enrolled. The mean age was 73.8±8.6 years and the mean CHA 2 DS 2 -VASc score was 4.2±1.5. The incidence of the primary safety end point was 0.5% with a 1-sided 95% upper CI of 1.6%, meeting the performance goal of 4.2% ( P <0.0001). The incidence of the primary effectiveness end point was 100%, with a 1-sided 95% lower CI of 99.1%, again meeting the performance goal of 97.0% ( P <0.0001). Device-related thrombus was reported in 7 patients, no patients experienced pericardial effusion requiring open cardiac surgery, and there were no device embolizations. Conclusions: LAA closure with this next-generation LAA closure device was associated with a low incidence of adverse events and a high incidence of anatomic closure. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02702271.
Complete percutaneous apical access and closure: Short and intermediate term outcomes
Eng, Marvin H. , Kherallah, Riyad , Guerrero, Mayra , Frisoli, Tiberio , Villablanca, Pedro , Wang, Dee Dee , Wyman, Janet , Wang, Dee Dee , Guerrero, Mayra E , Greenbaum, Adam B. , Lee, James , O’Neill, William W.

Catheterization and Cardiovascular Interventions | January 20, 2020 | Volume: 96 | Issue: 2 | Pages: 481-487

10.1002/ccd.28731 | PMID 31957915 Get It

AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Wood, David , Krajcer, Zvonimir , Sathananthan, Janarthanan , Strickman, Neil E., Metzger, Chris, Fearon, William F. , Aziz, Mark, Satler, Lowell F. , Waksman, Ron , Eng, Marvin H. , Heimansohn, David, Sampson, Andrew, Coady, Paul , Rodriguez, Roberto , Krishnaswamy, Amar , Lee, Jason T. , Ben‐Dor, Itsik , Moainie, Sina L. , Kodali, Susheel , Yadav, Pradeep , Kozak, Mark, Bacharach, J. Michael, Feldman, Ted , Nanjundappa, Aravinda , Bersin, Robert M., Potluri, Srinivasa , Barker, Colin M. , Bernardo, Nelson L. , Lumsden, Alan B. , Dake, Michael D. , Brown, David L. , Maor, Nathaniel, Nardone, Samuel, Webb, John G. , Investigators, on behalf of the SAFE MANTA Study, Kapadia, Samir , Greenbaum, Adam B. , Szerlip, Molly , Chhatriwalla, Adnan K , O’Neill, Brian Patrick , Guerrero, Mayra , Zhang, Ming , Barleben, Andrew R. , Campbell, John , Cohen, David Jonathan , Lauck, Sandra , O’Neill, William W. , Investigators, on behalf of the SAFE MANTA Study

Circulation: Cardiovascular Interventions | July 12, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007258 | PMID 31296082 Get It

Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.