Abstract Artificial intelligence (AI) and mucosal exposure devices like Endocuff have independently improved the adenoma detection rate (ADR) during colonoscopy. This meta-analysis evaluated the combined effect of Endocuff and AI versus AI alone on colorectal neoplasia detection rates. We searched PubMed, Embase, and Web of Science for randomized controlled trials (RCTs) comparing the impact of Endocuff+AI versus AI alone on colorectal neoplasia detection. Primary outcome was ADR; secondary outcomes included advanced adenoma detection rate (AADR), sessile serrated lesion detection rate (SSLDR), cecal intubation time, and withdrawal time. Pooled risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were calculated using a random-effects model. Three RCTs with 2404 subjects were included (n = 1198 Endocuff+AI vs. n = 1206 AI alone). ADR was significantly higher in the Endocuff+AI group than in the AI alone group (54% vs. 48%, respectively) (RR 1.12, 95% CI 1.03–1.21, P = 0.01, I2 = 0%). There was a trend toward higher AADR (12.3% vs. 10%, RR 1.23, 95% CI 0.96–1.59, P = 0.10, I2 = 17%) and SSLDR (17.6% vs. 15.5%, RR 1.16, 95% CI 0.96–1.40, P = 0.13, I2 = 0%) in the Endocuff+AI group compared with the AI alone group, but it did not reach statistical significance. Both cecal intubation time (MD -0.61 minutes; 95% CI -1.54–0.33; P = 0.20; I2 = 87%) and withdrawal time (MD -0.42 minutes; 95% CI -1.01–0.17; P = 0.17, I2 = 60%) were similar between the two groups. Endocuff combined with AI was superior to AI alone in improving the adenoma detection rate without increasing intubation or withdrawal times.
Computer‐aided detection for esophageal achalasia (with video)
ObjectivesAchalasia is an esophageal motility disorder that impairs quality of life and is often missed (20–50%) on endoscopy. A newly developed computer‐aided detection (CAD) software has shown high accuracy for achalasia diagnosis in preclinical settings. However, its benefit in a clinical setting remains unclear.MethodsBetween February and August 2023, 83 endoscopists from 27 centers assessed 50 randomized endoscopic videos (25 achalasia, 25 nonachalasia) without and with CAD. Endoscopists assessed videos without CAD, then with CAD after 2 months. The primary end‐point was improvement in sensitivity for nonexperienced endoscopists (no endoscopic experience of achalasia). Sensitivity, specificity, and accuracy with and without CAD were compared using the McNemar test.ResultsSensitivity for diagnosing achalasia increased significantly with CAD, rising from 74.2% (95% confidence interval [CI] 72.2–76.0%) to 91.2% (95% CI 89.9–92.4%) for all readers, showing a difference of 17.1% (95% CI 15.1–19.0%). Specifically, sensitivity improved from 66.9% (95% CI 63.6–70.0%) to 91.9% (95% CI 89.9–93.6%) among nonexperienced endoscopists, resulting in a difference of 25.0% (95% CI 21.7–28.4%), and from 79.5% (95% CI 77.1–81.8%) to 90.8% (95% CI 89.0–92.3%) among experienced endoscopists (endoscopic experience of at least one achalasia case), with a difference of 11.3% (95% CI 8.9–13.6%). Accuracy and specificity improved significantly with CAD assistance, regardless of reader's experience.ConclusionCAD improves achalasia detection by 17%, confirming preclinical results. The benefit was higher for nonexperienced endoscopists. CAD assistance may lead to prompt and effective treatment, minimizing the risk of false‐negative diagnosis in clinical practice.Trial registrationThis study was registered in the University Hospital Medical Information Network Clinical Trial Registry (https://www.umin.ac.jp/ctr/) number: UMIN000053047.
Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
Can optical evaluation distinguish between T1a and T1b esophageal adenocarcinoma: an international expert interobserver agreement study
Background Piecemeal endoscopic mucosal resection (EMR) is an acceptable technique for T1a esophageal adenocarcinoma, but en bloc R0 excision is advocated for T1b disease as it may offer a potential cure and mitigate recurrence. Thus, distinguishing between T1a and T1b disease is imperative under current treatment paradigms. We investigated whether expert Barrett’s endoscopists could make this distinction based on optical evaluation. Methods Endoscopic images of histologically confirmed high grade dysplasia (HGD), T1a, and T1b disease (20 sets for each) were compiled from consecutive patients at a single institution. Each set contained four images including an overview, a close-up in high definition white light, a near-focus magnification image, and a narrow-band image. Experts predicted the histology for each set. Results 19 experts from 8 countries (Australia, USA, Italy, Netherlands, Germany, Canada, Belgium, and Portugal) participated. The majority had been practicing for > 20 years, with a median (interquartile range) annual case volume of 50 (18–75) for Barrett’s EMR and 25 (10–45) for Barrett’s endoscopic submucosal dissection. Esophageal adenocarcinoma (T1a/b) could be distinguished from HGD with a pooled sensitivity of 89.1 % (95 %CI 84.7–93.4). T1b adenocarcinoma could be predicted with a pooled sensitivity of 43.8 % (95 %CI 29.9–57.7). Fleiss’ kappa was 0.421 (95 %CI 0.399–0.442; P < 0.001), indicating fair-to-moderate agreement. Conclusions Expert Barrett’s endoscopists could reliably differentiate T1a/T1b esophageal adenocarcinoma from HGD. Despite fair-to-moderate agreement for T staging, T1b disease could not be reliably distinguished from T1a disease. This may impact clinical decision making and selection of endoscopic techniques.
International consensus on the management of large (≥20 mm) colorectal laterally spreading tumors: World Endoscopy Organization Delphi study
ObjectivesThere have been significant advances in the management of large (≥20 mm) laterally spreading tumors (LSTs) or nonpedunculated colorectal polyps; however, there is a lack of clear consensus on the management of these lesions with significant geographic variability especially between Eastern and Western paradigms. We aimed to provide an international consensus to better guide management and attempt to homogenize practices.MethodsTwo experts in interventional endoscopy spearheaded an evidence‐based Delphi study on behalf of the World Endoscopy Organization Colorectal Cancer Screening Committee. A steering committee comprising six members devised 51 statements, and 43 experts from 18 countries on six continents participated in a three‐round voting process. The Grading of Recommendations, Assessment, Development and Evaluations tool was used to assess evidence quality and recommendation strength. Consensus was defined as ≥80% agreement (strongly agree or agree) on a 5‐point Likert scale.ResultsForty‐two statements reached consensus after three rounds of voting. Recommendations included: three statements on training and competency; 10 statements on preresection evaluation, including optical diagnosis, classification, and staging of LSTs; 14 statements on endoscopic resection indications and technique, including statements on en bloc and piecemeal resection decision‐making; seven statements on postresection evaluation; and eight statements on postresection care.ConclusionsAn international expert consensus based on the current available evidence has been developed to guide the evaluation, resection, and follow‐up of LSTs. This may provide guiding principles for the global management of these lesions and standardize current practices.
Establishing Standards for Gastrointestinal Endoscopic-Related Fluoroscopy: An International Expert Consensus Using a Modified Delphi Process
Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3–4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.
Benefits and challenges in implementation of artificial intelligence in colonoscopy: World Endoscopy Organization position statement
The number of artificial intelligence (AI) tools for colonoscopy on the market is increasing with supporting clinical evidence. Nevertheless, their implementation is not going smoothly for a variety of reasons, including lack of data on clinical benefits and cost‐effectiveness, lack of trustworthy guidelines, uncertain indications, and cost for implementation. To address this issue and better guide practitioners, the World Endoscopy Organization (WEO) has provided its perspective about the status of AI in colonoscopy as the position statement. WEO Position Statement: Statement 1.1: Computer‐aided detection (CADe) for colorectal polyps is likely to improve colonoscopy effectiveness by reducing adenoma miss rates and thus increase adenoma detection; Statement 1.2: In the short term, use of CADe is likely to increase health‐care costs by detecting more adenomas; Statement 1.3: In the long term, the increased cost by CADe could be balanced by savings in costs related to cancer treatment (surgery, chemotherapy, palliative care) due to CADe‐related cancer prevention; Statement 1.4: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADe to support its use in clinical practice; Statement 2.1: Computer‐aided diagnosis (CADx) for diminutive polyps (≤5 mm), when it has sufficient accuracy, is expected to reduce health‐care costs by reducing polypectomies, pathological examinations, or both; Statement 2.2: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADx to support its use in clinical practice; Statement 3: We recommend that a broad range of high‐quality cost‐effectiveness research should be undertaken to understand whether AI implementation benefits populations and societies in different health‐care systems.
Long-term outcomes of peroral endoscopic myotomy for achalasia: a systematic review and meta-analysis
Background The long-term outcomes of esophageal peroral endoscopic myotomy (POEM) are still unknown. Methods We searched electronic databases (MEDLINE/PubMed, EMBASE, Scopus) for studies assessing outcomes after POEM for esophageal achalasia with a minimum median follow-up duration of 36 months. Pooled rates of clinical success and postoperative reflux were calculated and compared with the same values at 12/24/36 months when available. Subgroup analyses were performed to explore the interstudy heterogeneity. Results From 1528 initial records, 11 studies (2017–2021) were included. A total of 2342 patients (age 48.1 [SD 6.8] years; 50.1 % males) with a median follow-up of 48 months (interquartile range 45–60) were analyzed. The pooled clinical success rate was 87.3 % (95 %CI 83.6 %–91.0 %; I2 = 73.1 %). The symptomatic reflux pooled rate was 22.0 % (95 %CI 14.4 %–29.5 %; I2 = 92.7 %). Three cases of peptic strictures and one Barrett’s esophagus were reported. The pooled rate of severe adverse events was 1.5 % (95 %CI 0.5 %–2.5 %; I2 = 52.8 %). Conclusions Long-term clinical efficacy of POEM persisted in 87 % of patients with achalasia. Post-POEM symptomatic reflux remained stable over time. The risk for Barrett’s esophagus and peptic strictures appeared minimal.
Submucosal tunnelling techniques for Zenker’s diverticulum: a systematic review of early outcomes with pooled analysis
In the last decade, flexible endoscopic septotomy has been reported as a well-tolerated and effective treatment for Zenker’s diverticulum. More recently, novel endoscopic submucosal tunneling techniques, namely Zenker-PerOral Endoscopic Myotomy (Z-POEM) and PerOral Endoscopic Septotomy (POES) have been proposed to obtain complete muscular septum exposure and deeper myotomy. The aim of this study is to provide a systematic review with a meta-analysis of the first experiences of third space approaches for Zenker’s diverticulum. Electronic databases (Medline, Scopus, EMBASE) were searched up to October 2020. Studies including patients with symptomatic Zenker’s diverticulum who underwent endoscopic treatment by submucosal tunneling technique were eligible. Procedural, clinical and safety outcomes were assessed by pooling data with a random-effect model to obtain a proportion with a 95% confidence interval. Nine retrospective studies were eligible for inclusion (196 patients). Five studies were performed in the USA, two in Europe and two in Asia. Endoscopic treatment was feasible in 96.9% (I 2 = 0%) of patients. The mean procedure duration was 36.4 ± 14.3 minutes. Clinical success was achieved after 93.4% (I 2 = 0%) of procedures. The overall adverse events rate was 4.9% (I 2 = 0%). No differences between the two approaches (Z-POEM vs POES) have been shown in terms of both efficacy and safety. Submucosal tunneling techniques appear to be feasible for symptomatic Zenker’s diverticulum, with promising results in terms of efficacy and safety outcomes.