Back to Authors

Ramchandani, Mohan

https://orcid.org/0000-0003-4656-5210

Mayo Clinic

Asian Institute of Gastroenterology

Citations 3

Endoscopic diagnosis and prevalence of early gastric cancer in India: A prospective study
Mohapatra, Ashutosh, Mohapatra, Sonmoon , Mahawar, Shruti, Pani, Krushna Chandra, Mohapatra, Nachiketa, Ramchandani, Mohan , Reddy, D. Nageshwar , Goenka, Mahesh Kumar , Uedo, Noriya , Goenka, Mahesh K

DEN Open | November 4, 2023 | Volume: 4 | Issue: 1 | Pages: No page available

10.1002/deo2.309 Get It

AbstractObjectivesAlthough countries like Japan and South Korea have implemented nationwide endoscopic screening programs, there is limited evidence on the effectiveness of endoscopy for diagnosing early gastric cancer (EGC) in developing countries such as India. In the present study, we aimed to determine the feasibility of endoscopic detection of EGC from India.MethodsThe data was prospectively collected for all patients ≥40 years who underwent a diagnostic upper endoscopy from April to September 2021. A single endoscopist who performed the endoscopic procedures completed 1‐month training in advanced endoscopy in Japan. Following the training, the endoscopist continued to engage in internet‐based discussions regarding his cases encountered. Prior to this training, the endoscopist had not detected any EGC cases during his 12‐year gastroenterology practice.ResultsA total of 1033 patients were included in the study, with males accounting for 65.4% and a mean age 52 years. The average procedural time was 7.13 ± 4.8 min. A total of 25 patients (2.4%) were found to have GC, including 6 patients (0.6%) with EGC. Two patients had synchronous EGC lesions. All EGC patients were males, with an average age of 66 years. All EGCs were detected in the distal stomach in the presence of Helicobacter pylori infection and severe atrophic gastritis.ConclusionOur findings showed that the endoscopic detection of EGC is feasible in India. Optimal training on endoscopic diagnosis of EGC can improve the detection of such lesion. Further studies are warranted to assess the optimization and implementation of an endoscopic screening program for EGC in India.
Benefits and challenges in implementation of artificial intelligence in colonoscopy: World Endoscopy Organization position statement
Hassan, Cesare , Halvorsen, Natalie , Berzin, Tyler M. , Renteln, Daniel von , Hewett, David G. , Repici, Alessandro , Ramchandani, Mohan , Khatry, Maryam Al , Yu, Honggang , Saito, Yutaka , Misawa, Masashi , Parasa, Sravanthi , Matsubayashi, Carolina Ogawa , Ogata, Haruhiko , Tajiri, Hisao, Ahmad, Omer F. , Rex, Douglas K. , Berzin, Tyler M , Hewett, David G , Wang, Pu , Saito, Yutaka , Misawa, Masashi , Matsubayashi, Carolina Ogawa , Hassan, Cesare , Mori, Yuichi , East, James E. , Byrne, Michael F. , Kudo, Shin‐ei , Wang, Pu , Pausawasdi, Nonthalee , Dekker, Evelien , Sharma, Prateek

Digestive Endoscopy | February 7, 2023 | Volume: 35 | Issue: 4 | Pages: 422-429

10.1111/den.14531 Get It

The number of artificial intelligence (AI) tools for colonoscopy on the market is increasing with supporting clinical evidence. Nevertheless, their implementation is not going smoothly for a variety of reasons, including lack of data on clinical benefits and cost‐effectiveness, lack of trustworthy guidelines, uncertain indications, and cost for implementation. To address this issue and better guide practitioners, the World Endoscopy Organization (WEO) has provided its perspective about the status of AI in colonoscopy as the position statement. WEO Position Statement: Statement 1.1: Computer‐aided detection (CADe) for colorectal polyps is likely to improve colonoscopy effectiveness by reducing adenoma miss rates and thus increase adenoma detection; Statement 1.2: In the short term, use of CADe is likely to increase health‐care costs by detecting more adenomas; Statement 1.3: In the long term, the increased cost by CADe could be balanced by savings in costs related to cancer treatment (surgery, chemotherapy, palliative care) due to CADe‐related cancer prevention; Statement 1.4: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADe to support its use in clinical practice; Statement 2.1: Computer‐aided diagnosis (CADx) for diminutive polyps (≤5 mm), when it has sufficient accuracy, is expected to reduce health‐care costs by reducing polypectomies, pathological examinations, or both; Statement 2.2: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADx to support its use in clinical practice; Statement 3: We recommend that a broad range of high‐quality cost‐effectiveness research should be undertaken to understand whether AI implementation benefits populations and societies in different health‐care systems.
Fine-needle aspiration of pancreatic cystic lesions: a randomized study with long-term follow-up comparing standard and flexible needles
Al‐Haddad, Mohammad , Wallace, Michael B. , Brugge, William R. , Li, Zhao-Shen, Sethi, Amrita , Pleskow, Douglas K. , Pannala, Rahul , Woodward, Timothy A., Ramchandani, Mohan , Jin, Zhendong , Xu, Can , Faigel, Douglas O. , Pleskow, Douglas , Raimondo, Massimo , Ramchandani, Mohan J , Wallace, Michael B , Al-Haddad, Mohammad , Lakhtakia, Sundeep , Li, Zhao‐Shen , Nguyen, Cuong Cao , DeWitt, John M.

Endoscopy | November 16, 2020 | Volume: 53 | Issue: 11 | Pages: 1132-1140

10.1055/a-1311-9927 Get It

Abstract Background Pancreatic cystic lesions (PCLs) are increasingly found on cross-sectional imaging, with the majority having a low risk for malignancy. The added value of fine-needle aspiration (FNA) in risk stratification remains unclear. We evaluated the impact of three FNA needles on diagnostic accuracy, clinical management, and the ability to accrue fluid for tumor markers. Methods A multicenter prospective trial randomized 250 patients with PCLs ≥ 13 mm 2:1:1 to 19G Flex, 19G, and 22G needles with crossover for repeated FNA procedures. Diagnostic accuracy was established at 2-year follow-up, with the final diagnosis from surgical histopathology or consensus diagnosis by experts based sequentially on clinical presentation, imaging, and aspirate analysis in blinded review. Results Enrolled patients (36 % symptomatic) had PCLs in the head (44 %), body (28 %), and tail (26 %). Percentage of cyst volume aspirated was 78 % (72 % – 84 %) for 19G Flex, 74 % (64 % – 84 %) for 22G, and 73 % (63 % – 83 %) for 19G (P = 0.84). Successful FNA was significantly higher for 19G Flex (89 % [82 % – 94 %]) and 22G (82 % [70 % – 90 %]) compared with 19G (75 % [63 % – 85 %]) (P = 0.02). Repeated FNA was required more frequently in head/uncinate lesions than in body and tail (P < 0.01). Diagnostic accuracy of the cyst aspirate was 84 % (73 % – 91 %) against histopathology at 2-year follow-up (n = 79), and 77 % (70 % – 83 %) against consensus diagnosis among nonsurgical cases (n = 171). Related serious adverse events occurred in 1.2 % (0.2 % – 3.5 %) of patients. Conclusions Our study results demonstrate a statistically significant difference among the three needles in the overall success rate for aspiration, but not in the percentage of cyst volume aspirated. Flexible needles may be particularly valuable in sampling cystic PCLs in the pancreatic head/uncinate process.