Back to Authors

Hassan, Cesare

0000-0001-7167-1459

Mayo Clinic

Humanitas University

Citations 15

Environmental impact of computer-aided diagnosis in colonoscopy: a carbon footprint assessment of a prospective study cohort
Olabintan, Olaolu , Halvorsen, Natalie , Baddeley, Robin , Kudo, Shin-ei, Barua, Ishita , Misawa, Masashi , Hunt, Claire , Nilsen, Jens Aksel , Frigstad, Svein Oskar , Rastogi, Amit, Holme, Øyvind , Gulati, Shraddha , Hassan, Cesare , Hayee, Bu , Mori, Yuichi , Kudo, Shin-ei, Mori, Kensaku , Hunt, Claire, East, James E. , Hassan, Cesare , Kalager, Mette , Løberg, Magnus , Haji, Amyn , Bretthauer, Michael , Mori, Yuichi

Endoscopy | October 7, 2025 | Volume: 58 | Issue: 03 | Pages: 303-309

10.1055/a-2717-8365 Get It

Abstract The environmental impact of computer-aided diagnosis (CADx) in colonoscopy is unknown. The potential to reduce greenhouse gas emissions by limiting unnecessary polypectomies may be offset by emissions associated with CADx devices. We quantified and compared the carbon footprint of colonoscopy with and without CADx. Life-cycle carbon emissions associated with endoscopic snares, polyp traps, histopathology, and CADx devices were estimated using life-cycle assessment software. The effect of CADx was estimated by the carbon dioxide equivalent (CO2e) emissions related to outcomes from a prospective cohort of patients who underwent colonoscopy with optical diagnosis under a leave-in-situ strategy (i.e. rectosigmoid polyps ≤5 mm predicted as non-neoplastic were not removed) with and without CADx assistance. We analyzed 1134 individuals (median age 67 years, 59% male) with 1716 colorectal polyps. Colonoscopy with CADx reduced the number of snares and polyp traps from 567 to 543 (difference: 24) and histopathology submissions from 1343 to 1278 (difference: 65). However, the total carbon footprint increased from 832 kg CO2e (95%CI 815 to 847) without CADx to 946 kg CO2e (95%CI 927 to 965) with CADx, corresponding to an absolute increase of 114 kg CO2e (95%CI 80 to 150) or 0.10 kg CO2e per colonoscopy. Using CADx under a leave-in-situ strategy increased the environmental burden of colonoscopy.
Artificial Intelligence-Assisted Colonoscopy With or Without Mucosal Exposure Device for Detection of Colorectal Adenomas: A Meta-Analysis
Beran, Azizullah , Ramai, Daryl, Albakri, Almaza A., Spadaccini, Marco , Hassan, Cesare , Guardiola, John , Rex, Douglas K., Spadaccini, Marco , Hassan, Cesare , Guardiola, John J , Nayfeh, Tarek , Saleem, Nasir , Repici, Alessandro

Endoscopy International Open | August 4, 2025 | Volume: 13 | Issue: CP | Pages: No page available

10.1055/a-2676-4144 Get It

Abstract Artificial intelligence (AI) and mucosal exposure devices like Endocuff have independently improved the adenoma detection rate (ADR) during colonoscopy. This meta-analysis evaluated the combined effect of Endocuff and AI versus AI alone on colorectal neoplasia detection rates. We searched PubMed, Embase, and Web of Science for randomized controlled trials (RCTs) comparing the impact of Endocuff+AI versus AI alone on colorectal neoplasia detection. Primary outcome was ADR; secondary outcomes included advanced adenoma detection rate (AADR), sessile serrated lesion detection rate (SSLDR), cecal intubation time, and withdrawal time. Pooled risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were calculated using a random-effects model. Three RCTs with 2404 subjects were included (n = 1198 Endocuff+AI vs. n = 1206 AI alone). ADR was significantly higher in the Endocuff+AI group than in the AI alone group (54% vs. 48%, respectively) (RR 1.12, 95% CI 1.03–1.21, P = 0.01, I2 = 0%). There was a trend toward higher AADR (12.3% vs. 10%, RR 1.23, 95% CI 0.96–1.59, P = 0.10, I2 = 17%) and SSLDR (17.6% vs. 15.5%, RR 1.16, 95% CI 0.96–1.40, P = 0.13, I2 = 0%) in the Endocuff+AI group compared with the AI alone group, but it did not reach statistical significance. Both cecal intubation time (MD -0.61 minutes; 95% CI -1.54–0.33; P = 0.20; I2 = 87%) and withdrawal time (MD -0.42 minutes; 95% CI -1.01–0.17; P = 0.17, I2 = 60%) were similar between the two groups. Endocuff combined with AI was superior to AI alone in improving the adenoma detection rate without increasing intubation or withdrawal times.
Position statement of the World Endoscopy Organization: Role of endoscopy in screening, diagnosis, and treatment of esophageal superficial squamous neoplasiaia
Hassan, Cesare , Goda, Kenichi, Iyer, Prasad G. , Awadhi, Sameer Al , Lehibi, Abed Al , Arantes, Vitor , Burgos, Herbert, Cerisoli, Cecilio L., Dawsey, Sanford, Fleischer, David, Fluxá, Fernando, Inoue, Haruhiro , John, Sneha , Khashab, Mouen A., Kothari, Shivangi , Lee, Yeong Yeh, Ngamruengphong, Saowanee , Sharara, Ala I. , Shimamura, Yuto , Varocha, Mahachai, Villa‐Gomez, Guido, Wang, Kenneth K. , Yip, Hon Chi , Sharma, Prateek , Lee, Yeong Yeh , Chiu, Philip Wai Yan , Emura, Fabian , G Iyer, Prasad, Kim, Gwang Ha , Shimamura, Yuto , Yip, Hon-Chi , Hassan, Cesare , Lee, Yeong Yeh , Antonelli, Giulio , Burgos, Herbert, Dawsey, Sanford, Draganov, Peter V. , González, Nicolás , Kashin, Sergey V. , Khashab, Mouen A. , Lee, Yeong Yeh, Remes Troche, José M , Varocha, Mahachai, Wang, Wen‐Lun

Digestive Endoscopy | December 26, 2024 | Volume: 37 | Issue: 5 | Pages: 470-489

10.1111/den.14967 Get It

Esophageal squamous cell carcinoma (ESCC) remains a significant global health challenge, being the sixth leading cause of cancer mortality with pronounced geographic variability. The incidence rates range from 125 per 100,000 in northern China to 1–1.5 per 100,000 in the United States, driven by environmental and lifestyle factors such as tobacco and alcohol use, dietary habits, and pollution. Major modifiable risk factors include tobacco and alcohol consumption, with a synergistic risk increase when combined. Nonmodifiable risk factors include previous diagnoses of head and neck squamous cell carcinoma (H&N SCC), achalasia, and prior radiotherapy. Prevention strategies must be tailored to specific regional burdens to efficiently allocate medical and financial resources. Gastrointestinal endoscopy is crucial in reducing ESCC burden through early detection and characterization of neoplastic changes, such as high‐grade dysplasia. Early diagnosis significantly improves survival rates, while endoscopic resection of noninvasive dysplasia can prevent ESCC onset, reducing treatment burden for advanced disease. Postresection surveillance can detect high‐risk metachronous lesions. Despite these benefits, endoscopic prevention faces challenges, including the lack of high‐level evidence supporting its efficacy, opportunity costs, the need for specialized training and techniques, and the requirement for advanced technology investments. This Position Statement from the World Endoscopy Organization (WEO) aims to address these challenges, supplying recommendations for the exploitation of endoscopic resources regarding the possible role of screening, quality, and training for the detection, characterization, resection, and surveillance of ESCC.
International Validation of a Novel PEACE Scale to Improve the Quality of Upper Gastrointestinal Mucosal Inspection During Endoscopy
Romańczyk, Marcin , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Bisschops, Raf , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, C. Prakash, Inoue, Haruhiro , Iyer, Prasad G. , Srinivasan, Sachin , Gyawali, C. Prakash , Hassan, Cesare , Gyawali, C P , Hassan, Cesare , Bisschops, Raf , Grover, Samir C , Kaminski, Michal Filip , Bugdol, Monika Natalia , Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Sharma, Prateek

Clinical and Translational Gastroenterology | November 14, 2024 | Volume: 16 | Issue: 1 | Pages: e00786

10.14309/ctg.0000000000000786 Get It

INTRODUCTION: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists. METHODS: In total, 39 EGD videos, with different degrees of mucosal cleanliness were retrieved from a previously conducted prospective trial. All experts rated the cleanliness of the mucosa on each video using the PEACE scale. To evaluate agreement of all scores (0–3), intraclass correlation coefficient 2.1 was used. The agreement on adequate (scores 2 and 3) and inadequate (scores 0 and 1) cleanliness was assessed using kappa values. RESULTS: Videos evaluating esophagus, stomach, and duodenum cleanliness were reviewed by 16 endoscopists. The PEACE scores demonstrated good agreement (intraclass correlation coefficient 0.82, 95% CI 0.75–0.89), especially for esophagus (0.84; 95% CI 0.71–0.95) and stomach (0.81; 95% CI 0.69–0.91), while agreement was moderate for the duodenum (0.69; 95% CI 0.51–0.87). The agreement was similar between Eastern (0.86; 95% CI 0.79–0.92) and Western experts (0.80; 95% CI 0.72–0.88). Similarly, agreement regarding adequate cleanliness was comparable between Eastern (0.70; 95% CI 0.55–0.85) and Western (0.74; 95% CI 0.64–0.84) endoscopists being overall 0.75 (95% CI 0.65–0.85). DISCUSSION: The PEACE scoring system is a simple and reliable scale to assess the cleanliness during EGD. The score is now validated among international experts with high concordance, justifying its use in clinical practice.
Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Khalaf, Kareem , Pawlak, Katarzyna M. , Alkandari, Asma , Baron, Todd H. , Bechara, Robert , Binda, Cecilia , Chen, Yen‐I , Moura, Eduardo Guimarães Hourneaux de , Forbes, Nauzer , James, Paul, Martin, Harry , May, Gary R. , Mosko, Jeffrey D. , Oyeleke, Ganiyat K. , Petersen, Bret T. , Saxena, Payal , Sethi, Amrita , Sharaiha, Reem Z. , Tang, Raymond S. , Villarroel, Mariano , Hooft, Jeanin E. van , Renteln, Daniel von , Walsh, Catharine M. , Aberin, Tricia, Banavage, Dawn, Chen, Jowell Akina, Clancy, James, Drake, Heather, Im, Melanie, Low, Chooi Peng, Myszko, Alexandra, Navarro, Krista, Redman, Jessica, Reyes, Wayne, Weinstein, Faina, Na, Caleb, Tham, Daniel , He, Tony , Malipatil, Sharan B., Gimpaya, Nikko , Kundra, Arjun , Grover, Samir C. , Barkun, Alan N , Bechara, Robert , Binda, Cecilia , de Moura, Eduardo , Hassan, Cesare , Kahaleh, Michel , Sharaiha, Reem Z , Villarroel, Mariano , van Hooft, Jeanin E , Voermans, Rogier P , von Renteln, Daniel , Walsh, Catharine M , Gupta, Sunil , Fujiyoshi, Yusuke , Grover, Samir C , Causada Calo, Natalia S , Pawlak, Katarzyna M , Adler, Douglas G. , Barkun, Alan , Berzin, Tyler M. , Cai, Ming‐Yan , Carrara, Silvia , Fugazza, Alessandro , Hassan, Cesare , James, Paul D., Kahaleh, Michel , Maselli, Roberta , Repici, Alessandro , Spadaccini, Marco , Teshima, Christopher , Voermans, Rogier P. , Clancy, James, Reyes, Wayne, Gupta, Sunil , Mokhtar, Ahmed H., Gholami, Reza

Endoscopy International Open | October 7, 2024 | Volume: 12 | Issue: 11 | Pages: E1315-E1325

10.1055/a-2427-3893 Get It

Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
Expert endoscopist assessment of colorectal polyp size using virtual scale endoscopy, visual or snare-based estimation: a prospective video-based study
Crainic, Ioana Popescu, Rex, Douglas K. , Hassan, Cesare , Pohl, Heiko , Rastogi, Amit, Anderson, Joseph C. , Taghiakbari, Mahsa , Medawar, Edgard , Renteln, Daniel von , East, James, Hassan, Cesare , Djinbachian, Roupen , Barkun, Alan , Shaukat, Aasma , East, James E. , Mori, Yuichi , Sharma, Prateek

Scandinavian Journal of Gastroenterology | February 9, 2024 | Volume: 59 | Issue: 5 | Pages: 608-614

10.1080/00365521.2024.2308519 Get It

Benefits and challenges in implementation of artificial intelligence in colonoscopy: World Endoscopy Organization position statement
Hassan, Cesare , Halvorsen, Natalie , Berzin, Tyler M. , Renteln, Daniel von , Hewett, David G. , Repici, Alessandro , Ramchandani, Mohan , Khatry, Maryam Al , Yu, Honggang , Saito, Yutaka , Misawa, Masashi , Parasa, Sravanthi , Matsubayashi, Carolina Ogawa , Ogata, Haruhiko , Tajiri, Hisao, Ahmad, Omer F. , Rex, Douglas K. , Berzin, Tyler M , Hewett, David G , Wang, Pu , Saito, Yutaka , Misawa, Masashi , Matsubayashi, Carolina Ogawa , Hassan, Cesare , Mori, Yuichi , East, James E. , Byrne, Michael F. , Kudo, Shin‐ei , Wang, Pu , Pausawasdi, Nonthalee , Dekker, Evelien , Sharma, Prateek

Digestive Endoscopy | February 7, 2023 | Volume: 35 | Issue: 4 | Pages: 422-429

10.1111/den.14531 Get It

The number of artificial intelligence (AI) tools for colonoscopy on the market is increasing with supporting clinical evidence. Nevertheless, their implementation is not going smoothly for a variety of reasons, including lack of data on clinical benefits and cost‐effectiveness, lack of trustworthy guidelines, uncertain indications, and cost for implementation. To address this issue and better guide practitioners, the World Endoscopy Organization (WEO) has provided its perspective about the status of AI in colonoscopy as the position statement. WEO Position Statement: Statement 1.1: Computer‐aided detection (CADe) for colorectal polyps is likely to improve colonoscopy effectiveness by reducing adenoma miss rates and thus increase adenoma detection; Statement 1.2: In the short term, use of CADe is likely to increase health‐care costs by detecting more adenomas; Statement 1.3: In the long term, the increased cost by CADe could be balanced by savings in costs related to cancer treatment (surgery, chemotherapy, palliative care) due to CADe‐related cancer prevention; Statement 1.4: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADe to support its use in clinical practice; Statement 2.1: Computer‐aided diagnosis (CADx) for diminutive polyps (≤5 mm), when it has sufficient accuracy, is expected to reduce health‐care costs by reducing polypectomies, pathological examinations, or both; Statement 2.2: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADx to support its use in clinical practice; Statement 3: We recommend that a broad range of high‐quality cost‐effectiveness research should be undertaken to understand whether AI implementation benefits populations and societies in different health‐care systems.
Long-term outcomes of peroral endoscopic myotomy for achalasia: a systematic review and meta-analysis
Vespa, Edoardo , Chandrasekar, Viveksandeep Thoguluva , Spadaccini, Marco , Patel, Harsh K. , Maselli, Roberta , Carlani, Elisa , Hassan, Cesare , Repici, Alessandro , Chandrasekar, Viveksandeep T , Spadaccini, Marco , Hassan, Cesare , Pellegatta, Gaia , Galtieri, P.A. , Sharma, Prateek

Endoscopy | July 7, 2022 | Volume: 55 | Issue: 02 | Pages: 167-175

10.1055/a-1894-0147 Get It

Background The long-term outcomes of esophageal peroral endoscopic myotomy (POEM) are still unknown. Methods We searched electronic databases (MEDLINE/PubMed, EMBASE, Scopus) for studies assessing outcomes after POEM for esophageal achalasia with a minimum median follow-up duration of 36 months. Pooled rates of clinical success and postoperative reflux were calculated and compared with the same values at 12/24/36 months when available. Subgroup analyses were performed to explore the interstudy heterogeneity. Results From 1528 initial records, 11 studies (2017–2021) were included. A total of 2342 patients (age 48.1 [SD 6.8] years; 50.1 % males) with a median follow-up of 48 months (interquartile range 45–60) were analyzed. The pooled clinical success rate was 87.3 % (95 %CI 83.6 %–91.0 %; I2 = 73.1 %). The symptomatic reflux pooled rate was 22.0 % (95 %CI 14.4 %–29.5 %; I2 = 92.7 %). Three cases of peptic strictures and one Barrett’s esophagus were reported. The pooled rate of severe adverse events was 1.5 % (95 %CI 0.5 %–2.5 %; I2 = 52.8 %). Conclusions Long-term clinical efficacy of POEM persisted in 87 % of patients with achalasia. Post-POEM symptomatic reflux remained stable over time. The risk for Barrett’s esophagus and peptic strictures appeared minimal.
Definition of competence standards for optical diagnosis of diminutive colorectal polyps: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement
Houwen, Britt B. S. L. , Hassan, Cesare , Greuter, Marjolein J.E. , Hazewinkel, Yark, Vleugels, Jasper L.A., Antonelli, Giulio , Bustamante, Marco , Coron, Emmanuel , Cortas, George, Dinis‐Ribeiro, Mário , Dobru, Daniela , Iacucci, Marietta , Jover, Rodrigo , Kuvaev, Roman , Neumann, Helmut , Rutter, Matthew D. , Saunders, Brian P. , Tate, David J. , Bisschops, Raf , Dekker, Evelien , Bustamante-Balén, Marco , Neumann, Helmut , Pellisé, Maria , Puig, Ignasi , Rutter, Matthew D , Mori, Yuichi , Bisschops, Raf , Dekker, Evelien , Hassan, Cesare , Iacucci, Marietta , Coupé, Veerle M.H. , East, James E. , Mori, Yuichi , Longcroft‐Wheaton, Gaius

Endoscopy | December 6, 2021 | Volume: 54 | Issue: 01 | Pages: 88-99

10.1055/a-1689-5130 Get It

Abstract Background The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 – 5 mm). Methods A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds. Recommendation 1 In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm in the rectosigmoid. Histopathology is used as the gold standard. Level of agreement 95 %. Recommendation 2 In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm. Histopathology is used as the gold standard. Level of agreement 100 %. Conclusion The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.