Back to Authors

Berzin, Tyler M.

https://orcid.org/0000-0002-4364-6210

Mayo Clinic

Beth Israel Deaconess Medical Center

Citations 9

US multicenter outcomes of endoscopic ultrasound-guided gallbladder drainage with lumen-apposing metal stents for acute cholecystitis
David, Yakira , Kakked, Gaurav, Confer, Bradley , Shah, Ruchit N. , Khara, Harshit S. , Diehl, David L. , Krafft, Matthew , Shah-Khan, Sardar M. , Nasr, John , Benias, Petros C. , Muniraj, Thiruvengadam , Aslanian, Harry R., Chahal, Prabhleen , Rodriguez, John , DuBroff, Jason, Latour, Rabi De, Khanna, Lauren , Haber, Gregory , Hoerter, Nicholas A. , Pandey, Nishi , Bakhit, Mena , Kowalski, Thomas E., Loren, David E. , Chiang, Austin , Schlachterman, Alexander , Nieto, Jose , Ichkhanian, Yervant , Khashab, Mouen A. , Halabi, Maan El , Kwon, Richard S. , Hernandez-Lara, Ariosto, Poneros, John M., Sethi, Amrita, Gonda, Tamas A. , Kushnir, Vladimir , Cosgrove, Natalie , Mullady, Daniel , Al-Shahrani, Abdullah , Buscaglia, Jonathan M. , Bucobo, Juan Carlos , Rolston, Vineet S. , Kedia, Prashant , Kasmin, Franklin, Kumta, Nikhil A. , DiMaio, Christopher J. , Krafft, Matthew Richard , Trindade, Arvind J. , Adler, Douglas G. , Tzimas, Demetrios J. , Goodman, Adam J. , Nieto, José , Deshmukh, Ameya A. , Prabhu, Anoop , Storm, Andrew C. , Berzin, Tyler M. , Sethi, Amrita , D'Souza, Lionel S. , Nagula, Satish

Endoscopy International Open | January 13, 2025 | Volume: 13 | Issue: CP | Pages: No page available

10.1055/a-2495-5542 Get It

AbstractEUS-guided gallbladder drainage (EUS-GBD) using lumen apposing metal stents (LAMS) has excellent technical and short-term clinical success for acute cholecystitis (AC). The goals of this study were to determine the long-term clinical outcomes and adverse events (AEs) of EUS-GBD with LAMS.A multicenter, retrospective study was conducted at 18 US tertiary care institutions. Inclusion criteria: any AC patient with attempted EUS-GBD with LAMS and minimum 30-day post-procedure follow-up. Long-term clinical success was defined as absence of recurrent acute cholecystitis (RAC) > 30 days and long-term AE was defined as occurring > 30 days from the index procedure.A total of 109 patients were included. Technical success was achieved in 108 of 109 (99.1%) and initial clinical success in 106 of 109 (97.2%). Long-term clinical success was achieved in 98 of 109 (89.9%) over a median follow-up of 140 days (range 30–1188). On multivariable analysis (MVA), acalculous cholecystitis (odds ratio [OR] 15.93, 95% confidence interval [CI] 1.22–208.52, P = 0.04) and the occurrence of a LAMS-specific AE (OR 63.60, 95% CI 5.08–799.29, P <0.01) were associated with RAC. AEs occurred in 38 of 109 patients (34.9%) at any time, and in 10 of 109 (9.17%) > 30 days from the index procedure. Most long-term AEs (7 of 109; 6.42%) were LAMS-specific. No technical or clinical factors were associated with occurrence of AEs. LAMS were removed in 24 of 109 patients (22%). There was no difference in RAC or AEs whether LAMS was removed or not.EUS-GBD with LAMS has a high rate of long-term clinical success and modest AE rates in patients with AC and is a reasonable destination therapy for high-risk surgical candidates.
S2152 Understanding of Artificial Intelligence in Healthcare Among Gastroenterology Fellows and Early Career Gastroenterologists
Khanna, Sahil , Tariq, Raseen , Dilmaghani, Saam , Soroush, Ali , Berzin, Tyler M.

American Journal of Gastroenterology | October 24, 2024 | Volume: 119 | Issue: 10S | Pages: S1535-S1535

10.14309/01.ajg.0001037976.48093.8d Get It

Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Khalaf, Kareem , Pawlak, Katarzyna M. , Alkandari, Asma , Baron, Todd H. , Bechara, Robert , Binda, Cecilia , Chen, Yen‐I , Moura, Eduardo Guimarães Hourneaux de , Forbes, Nauzer , James, Paul, Martin, Harry , May, Gary R. , Mosko, Jeffrey D. , Oyeleke, Ganiyat K. , Petersen, Bret T. , Saxena, Payal , Sethi, Amrita , Sharaiha, Reem Z. , Tang, Raymond S. , Villarroel, Mariano , Hooft, Jeanin E. van , Renteln, Daniel von , Walsh, Catharine M. , Aberin, Tricia, Banavage, Dawn, Chen, Jowell Akina, Clancy, James, Drake, Heather, Im, Melanie, Low, Chooi Peng, Myszko, Alexandra, Navarro, Krista, Redman, Jessica, Reyes, Wayne, Weinstein, Faina, Na, Caleb, Tham, Daniel , He, Tony , Malipatil, Sharan B., Gimpaya, Nikko , Kundra, Arjun , Grover, Samir C. , Barkun, Alan N , Bechara, Robert , Binda, Cecilia , de Moura, Eduardo , Hassan, Cesare , Kahaleh, Michel , Sharaiha, Reem Z , Villarroel, Mariano , van Hooft, Jeanin E , Voermans, Rogier P , von Renteln, Daniel , Walsh, Catharine M , Gupta, Sunil , Fujiyoshi, Yusuke , Grover, Samir C , Causada Calo, Natalia S , Pawlak, Katarzyna M , Adler, Douglas G. , Barkun, Alan , Berzin, Tyler M. , Cai, Ming‐Yan , Carrara, Silvia , Fugazza, Alessandro , Hassan, Cesare , James, Paul D., Kahaleh, Michel , Maselli, Roberta , Repici, Alessandro , Spadaccini, Marco , Teshima, Christopher , Voermans, Rogier P. , Clancy, James, Reyes, Wayne, Gupta, Sunil , Mokhtar, Ahmed H., Gholami, Reza

Endoscopy International Open | October 7, 2024 | Volume: 12 | Issue: 11 | Pages: E1315-E1325

10.1055/a-2427-3893 Get It

Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
Risk of Pancreatitis After Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Cystic Lesions: A Systematic Review and Meta-Analysis
Magahis, Patrick T. , Chhoda, Ankit , Berzin, Tyler M. , Farrell, James J. , Wright, Drew , Rizvi, Anam, Hanscom, Mark , Carr-Locke, David L., Sampath, Kartik, Sharaiha, Reem Z. , Mahadev, SriHari , Wright, Drew N , Berzin, Tyler M , Carr‐Locke, David L.

American Journal of Gastroenterology | July 8, 2024 | Volume: 119 | Issue: 11 | Pages: 2174-2186

10.14309/ajg.0000000000002942 Get It

INTRODUCTION: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is frequently used to risk-stratify pancreatic cystic lesions (PCLs). Rising PCL incidence and developments in tissue acquisition and specimen analysis necessitate updated appraisal of EUS-FNA safety, particularly the risk of postprocedure pancreatitis, the most common EUS-FNA-related adverse event. Our systematic review aims to accurately quantify the risk of EUS-FNA-related pancreatitis to best inform decisions regarding EUS-FNA's optimal role in PCL workup. METHODS: We performed systematic searches in 4 databases from inception to April 2024 for original English-language studies investigating EUS-FNA-related pancreatitis. We extracted data on demographics and EUS-FNA-related pancreatitis risk, severity, and risk factors. These were meta-analyzed through the DerSimonian Laird Method using a random-effects model. Meta-regression of pancreatitis risk was performed to delineate associations with clinical and procedural characteristics. RESULTS: Sixty-four studies comprised 8,086 patients and reported 110 EUS-FNA-related pancreatitis events. Pooled risk of EUS-FNA-related pancreatitis was 1.4% (95% confidence intervals, −0.8% to 3.5%; I 2 = 0.00), which was predominantly of mild severity (67%) and uniformly nonfatal. Pancreatitis risk lacked significant association with sample size, age, sex, cyst size, needle caliber, or passes, although we noted trends toward higher risk in studies published after 2015, those using higher gauge needles (19 G vs 22 G/25 G), and those performing EUS-guided through-the-needle biopsy. DISCUSSION: We note with high certainty that pancreatitis after EUS-FNA of PCLs is infrequent and mild in severity with no mortality in the included cohort. EUS-guided through-the-needle biopsy may serve as a significant risk factor for EUS-FNA-related pancreatitis risk; however, further studies are needed to delineate other predisposing characteristics.
S2624 Novel Hemostatic Agent as a Modality for Post-sphincterotomy Bleeding
Igbinedion, Samuel , Holzwanger, Erik , Mahmood, Sultan , Sawhney, Mandeep , Gabr, Moamen , Ghanem, Ahmed, Pleskow, Douglas K. , Berzin, Tyler M.

American Journal of Gastroenterology | October 18, 2023 | Volume: 118 | Issue: 10S | Pages: S1811-S1811

10.14309/01.ajg.0000960136.16449.c4 Get It

Benefits and challenges in implementation of artificial intelligence in colonoscopy: World Endoscopy Organization position statement
Hassan, Cesare , Halvorsen, Natalie , Berzin, Tyler M. , Renteln, Daniel von , Hewett, David G. , Repici, Alessandro , Ramchandani, Mohan , Khatry, Maryam Al , Yu, Honggang , Saito, Yutaka , Misawa, Masashi , Parasa, Sravanthi , Matsubayashi, Carolina Ogawa , Ogata, Haruhiko , Tajiri, Hisao, Ahmad, Omer F. , Rex, Douglas K. , Berzin, Tyler M , Hewett, David G , Wang, Pu , Saito, Yutaka , Misawa, Masashi , Matsubayashi, Carolina Ogawa , Hassan, Cesare , Mori, Yuichi , East, James E. , Byrne, Michael F. , Kudo, Shin‐ei , Wang, Pu , Pausawasdi, Nonthalee , Dekker, Evelien , Sharma, Prateek

Digestive Endoscopy | February 7, 2023 | Volume: 35 | Issue: 4 | Pages: 422-429

10.1111/den.14531 Get It

The number of artificial intelligence (AI) tools for colonoscopy on the market is increasing with supporting clinical evidence. Nevertheless, their implementation is not going smoothly for a variety of reasons, including lack of data on clinical benefits and cost‐effectiveness, lack of trustworthy guidelines, uncertain indications, and cost for implementation. To address this issue and better guide practitioners, the World Endoscopy Organization (WEO) has provided its perspective about the status of AI in colonoscopy as the position statement. WEO Position Statement: Statement 1.1: Computer‐aided detection (CADe) for colorectal polyps is likely to improve colonoscopy effectiveness by reducing adenoma miss rates and thus increase adenoma detection; Statement 1.2: In the short term, use of CADe is likely to increase health‐care costs by detecting more adenomas; Statement 1.3: In the long term, the increased cost by CADe could be balanced by savings in costs related to cancer treatment (surgery, chemotherapy, palliative care) due to CADe‐related cancer prevention; Statement 1.4: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADe to support its use in clinical practice; Statement 2.1: Computer‐aided diagnosis (CADx) for diminutive polyps (≤5 mm), when it has sufficient accuracy, is expected to reduce health‐care costs by reducing polypectomies, pathological examinations, or both; Statement 2.2: Health‐care delivery systems and authorities should evaluate the cost‐effectiveness of CADx to support its use in clinical practice; Statement 3: We recommend that a broad range of high‐quality cost‐effectiveness research should be undertaken to understand whether AI implementation benefits populations and societies in different health‐care systems.
Establishing key research questions for the implementation of artificial intelligence in colonoscopy: a modified Delphi method
Ahmad, Omer F. , Mori, Yuichi , Misawa, Masashi , Kudo, Toyoki , Anderson, J. , Bernal, Jorge , Bisschops, Raf , Chen, Peng‐Jen , Eelbode, Tom , Elson, Daniel S. , Gurudu, Suryakanth, Histace, Aymeric , Karnes, William E. , Repici, Alessandro , Singh, Rajvinder , Valdastri, Pietro , Wallace, Michael B. , Wang, Pu , Lovat, Laurence , Kudo, Shin-Ei , Anderson, John T , Bisschops, Raf , Chen, Peng-Jen , East, James E , Gurudu, Suryakanth R, Histace, Aymeric , Wallace, Michael B , Wang, Pu , Mori, Yuichi , Berzin, Tyler M. , Byrne, Michael F. , East, James E. , Stoyanov, Danail V.

Endoscopy | November 10, 2020 | Volume: 53 | Issue: 09 | Pages: 893-901

10.1055/a-1306-7590 Get It

Abstract Background Artificial intelligence (AI) research in colonoscopy is progressing rapidly but widespread clinical implementation is not yet a reality. We aimed to identify the top implementation research priorities. Methods An established modified Delphi approach for research priority setting was used. Fifteen international experts, including endoscopists and translational computer scientists/engineers, from nine countries participated in an online survey over 9 months. Questions related to AI implementation in colonoscopy were generated as a long-list in the first round, and then scored in two subsequent rounds to identify the top 10 research questions. Results The top 10 ranked questions were categorized into five themes. Theme 1: clinical trial design/end points (4 questions), related to optimum trial designs for polyp detection and characterization, determining the optimal end points for evaluation of AI, and demonstrating impact on interval cancer rates. Theme 2: technological developments (3 questions), including improving detection of more challenging and advanced lesions, reduction of false-positive rates, and minimizing latency. Theme 3: clinical adoption/integration (1 question), concerning the effective combination of detection and characterization into one workflow. Theme 4: data access/annotation (1 question), concerning more efficient or automated data annotation methods to reduce the burden on human experts. Theme 5: regulatory approval (1 question), related to making regulatory approval processes more efficient. Conclusions This is the first reported international research priority setting exercise for AI in colonoscopy. The study findings should be used as a framework to guide future research with key stakeholders to accelerate the clinical implementation of AI in endoscopy.
Volumetric laser endomicroscopy and its application to Barrett's esophagus: results from a 1,000 patient registry
Smith, Michael S. , Konda, Vani J. , Gordon, Stuart R. , DeMeester, Steven R. , Joshi, Vivek , Ganguly, Eric K. , Mashimo, Hiroshi , Jobe, Blair A. , McKinley, Matthew , Wallace, Michael B. , Thakkar, Shyam , Schnoll‐Sussman, Felice , Sharaiha, Reem Z. , Tarnasky, P, Wolfsen, Herbert C. , Hawes, Robert H. , Lipham, John C. , Khara, Harshit S. , Navaneethan, U, Kedia, Prashant , Hasan, Muhammad K. , Sethi, Amrita , Samarasena, Jason , Siddiqui, Uzma D. , Gress, Frank G., Rodríguez, Reynaldo , Lee, C, Gonda, Tamas A. , Waxman, Irving , Hyder, S., Poneros, John M., Sharzehi, Kaveh , Palma, Jack A. Di, Sejpal, Divyesh V., Hagen, J. A., Rothstein, Richard, Sawhney, Mandeep , Malik, Zubair , Chang, Kenneth J. , Fichera, Alessandro , Gaidhane, Monica , Wallace, Michael B , Cash, Brooks D. , Trindade, Arvind J. , Diehl, David L. , Singh, Satish K. , Komatsu, Y, Kahaleh, Michel , Pleskow, Douglas K. , Hyder, S, Oh, Daniel S. , Berzin, Tyler M.

Diseases of the Esophagus | April 30, 2019 | Volume: 32 | Issue: 9 | Pages: No page available

10.1093/dote/doz029 Get It

SUMMARY Volumetric laser endomicroscopy (VLE) uses optical coherence tomography (OCT) for real-time, microscopic cross-sectional imaging. A US-based multi-center registry was constructed to prospectively collect data on patients undergoing upper endoscopy during which a VLE scan was performed. The objective of this registry was to determine usage patterns of VLE in clinical practice and to estimate quantitative and qualitative performance metrics as they are applied to Barrett's esophagus (BE) management. All procedures utilized the NvisionVLE Imaging System (NinePoint Medical, Bedford, MA) which was used by investigators to identify the tissue types present, along with focal areas of concern. Following the VLE procedure, investigators were asked to answer six key questions regarding how VLE impacted each case. Statistical analyses including neoplasia diagnostic yield improvement using VLE was performed. One thousand patients were enrolled across 18 US trial sites from August 2014 through April 2016. In patients with previously diagnosed or suspected BE (894/1000), investigators used VLE and identified areas of concern not seen on white light endoscopy (WLE) in 59% of the procedures. VLE imaging also guided tissue acquisition and treatment in 71% and 54% of procedures, respectively. VLE as an adjunct modality improved the neoplasia diagnostic yield by 55% beyond the standard of care practice. In patients with no prior history of therapy, and without visual findings from other technologies, VLE-guided tissue acquisition increased neoplasia detection over random biopsies by 700%. Registry investigators reported that VLE improved the BE management process when used as an adjunct tissue acquisition and treatment guidance tool. The ability of VLE to image large segments of the esophagus with microscopic cross-sectional detail may provide additional benefits including higher yield biopsies and more efficient tissue acquisition. Clinicaltrials.gov NCT02215291