AbstractEUS-guided gallbladder drainage (EUS-GBD) using lumen apposing metal stents (LAMS) has excellent technical and short-term clinical success for acute cholecystitis (AC). The goals of this study were to determine the long-term clinical outcomes and adverse events (AEs) of EUS-GBD with LAMS.A multicenter, retrospective study was conducted at 18 US tertiary care institutions. Inclusion criteria: any AC patient with attempted EUS-GBD with LAMS and minimum 30-day post-procedure follow-up. Long-term clinical success was defined as absence of recurrent acute cholecystitis (RAC) > 30 days and long-term AE was defined as occurring > 30 days from the index procedure.A total of 109 patients were included. Technical success was achieved in 108 of 109 (99.1%) and initial clinical success in 106 of 109 (97.2%). Long-term clinical success was achieved in 98 of 109 (89.9%) over a median follow-up of 140 days (range 30–1188). On multivariable analysis (MVA), acalculous cholecystitis (odds ratio [OR] 15.93, 95% confidence interval [CI] 1.22–208.52, P = 0.04) and the occurrence of a LAMS-specific AE (OR 63.60, 95% CI 5.08–799.29, P <0.01) were associated with RAC. AEs occurred in 38 of 109 patients (34.9%) at any time, and in 10 of 109 (9.17%) > 30 days from the index procedure. Most long-term AEs (7 of 109; 6.42%) were LAMS-specific. No technical or clinical factors were associated with occurrence of AEs. LAMS were removed in 24 of 109 patients (22%). There was no difference in RAC or AEs whether LAMS was removed or not.EUS-GBD with LAMS has a high rate of long-term clinical success and modest AE rates in patients with AC and is a reasonable destination therapy for high-risk surgical candidates.
Volumetric laser endomicroscopy and its application to Barrett's esophagus: results from a 1,000 patient registry
SUMMARY Volumetric laser endomicroscopy (VLE) uses optical coherence tomography (OCT) for real-time, microscopic cross-sectional imaging. A US-based multi-center registry was constructed to prospectively collect data on patients undergoing upper endoscopy during which a VLE scan was performed. The objective of this registry was to determine usage patterns of VLE in clinical practice and to estimate quantitative and qualitative performance metrics as they are applied to Barrett's esophagus (BE) management. All procedures utilized the NvisionVLE Imaging System (NinePoint Medical, Bedford, MA) which was used by investigators to identify the tissue types present, along with focal areas of concern. Following the VLE procedure, investigators were asked to answer six key questions regarding how VLE impacted each case. Statistical analyses including neoplasia diagnostic yield improvement using VLE was performed. One thousand patients were enrolled across 18 US trial sites from August 2014 through April 2016. In patients with previously diagnosed or suspected BE (894/1000), investigators used VLE and identified areas of concern not seen on white light endoscopy (WLE) in 59% of the procedures. VLE imaging also guided tissue acquisition and treatment in 71% and 54% of procedures, respectively. VLE as an adjunct modality improved the neoplasia diagnostic yield by 55% beyond the standard of care practice. In patients with no prior history of therapy, and without visual findings from other technologies, VLE-guided tissue acquisition increased neoplasia detection over random biopsies by 700%. Registry investigators reported that VLE improved the BE management process when used as an adjunct tissue acquisition and treatment guidance tool. The ability of VLE to image large segments of the esophagus with microscopic cross-sectional detail may provide additional benefits including higher yield biopsies and more efficient tissue acquisition. Clinicaltrials.gov NCT02215291