Back to Authors

Sejpal, Divyesh V.

Mayo Clinic

Creighton University

Citations 10

Global prospective case series of ERCPs using a single-use duodenoscope
Bruno, Marco J. , Beyna, Torsten , Carr‐Locke, David L. , Chahal, Prabhleen , Costamagna, Guido , Devereaux, Benedict , Giovannini, Marc, Khor, Christopher , Lau, James Y., May, Gary R. , Muthusamy, V. Raman , Petersen, Bret T. , Raijman, Isaac , Reddy, D. Nageshwar , Ross, Andrew S., Sejpal, Divyesh V., Sherman, Stuart , Siddiqui, Uzma D. , Ziady, Christopher, Peetermans, Joyce , Rousseau, Matthew , Slivka, Adam, Group, EXALT Single-use Duodenoscope Study, Fichera, Alessandro , Pleskow, Douglas , Goenka, Mahesh Kumar , Patel, Sandeep , Petersen, Bret T. , Pleskow, Douglas K. , Repici, Alessandro , Group, EXALT Single-use Duodenoscope Study

Endoscopy | July 18, 2023 | Volume: 55 | Issue: 12 | Pages: 1103-1114

10.1055/a-2131-7180 Get It

Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3–4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.
First interobserver agreement of optical coherence tomography in the bile duct: A multicenter collaborative study
Tyberg, Amy , Raijman, Isaac , Sarkar, Avik , Samarasena, Jason , Andalib, Iman , Diehl, David L. , Pleskow, Douglas K. , Woods, Kevin E. , Gordon, Stuart R. , Pannala, Rahul , Kedia, Prashant , Tarnasky, Paul R., Sejpal, Divyesh V., Kumta, Nikhil A. , Parasher, Gulshan , Adler, Douglas G., Patel, Kalpesh, Siddiqui, Uzma D. , Joshi, Viren, Pleskow, Douglas , Gaidhane, Monica , Trindade, Arvind J. , Shahid, Haroon M. , Draganov, Peter V. , Adler, Douglas G. , Yang, Dennis J. , Kahaleh, Michel , Joshi, Viren

Endoscopy International Open | March 23, 2022 | Volume: 10 | Issue: 08 | Pages: E1065-E1072

10.1055/a-1779-5027 Get It

Abstract Background and study aims Optical coherence tomography (OCT) is a new technology available for evaluation of indeterminate biliary strictures. It allows under-the-surface visualization and preliminary studies have confirmed standardized characteristics associated with malignancy. The aim of this study is to evaluate the first interobserver agreement in identifying previously agreed upon OCT criteria and diagnosing of malignant versus benign disease. Patients and methods Fourteen endoscopists were asked to review an atlas of reference clips and images of eight criteria derived from expert consensus A total of 35 de-identified video clips were then evaluated for presence of the eight criteria and for final diagnosis of malignant versus benign using the atlas as reference Intraclass correlation (ICC) analysis was done to evaluate interrater agreement. Results Clips of 23 malignant lesions and 12 benign lesions were scored. Excellent interobserver agreement was seen with dilated hypo-reflective structures (0.85) and layering effacement (0.89); hyper-glandular mucosa (0.76), intact layering (0.81), and onion-skin layering (0.77); fair agreement was seen with scalloping (0.58), and thickened epithelium (0.4); poor agreement was seen with hyper-reflective surface (0.36). The diagnostic ICC for both neoplastic (0.8) and non-neoplastic (0.8) was excellent interobserver agreement. The overall diagnostic accuracy was 51 %, ranging from 43 % to 60 %. Conclusions Biliary OCT is a promising new modality for evaluation of indeterminate biliary strictures. Interobserver agreement ranged from fair to almost perfect on eight previously identified criteria. Interobserver agreement for malignancy diagnosis was substantial (0.8). Further studies are needed to validate this data.
Endoscopic resection outcomes and predictors of failed en bloc endoscopic mucosal resection of colorectal polyps ≤ 20 mm among advanced endoscopy trainees
King, William , Draganov, Peter V. , Uppal, Dushant, Rumman, Amir , Kumta, Nikhil A. , DiMaio, Christopher J. , Sejpal, Divyesh V., Bucobo, Juan Carlos , Gómez, Victoria , Wallace, Michael B. , Pohl, Heiko , Wallace, Michael B , Wang, Andrew Y. , Trindade, Arvind J. , D'Souza, Lionel S. , Yang, Dennis J.

Endoscopy International Open | November 12, 2021 | Volume: 09 | Issue: 11 | Pages: E1820-E1826

10.1055/a-1578-1965 Get It

Abstract Background and study aims En bloc endoscopic mucosal resection (EMR) is preferred over piecemeal resection for polyps ≤ 20 mm. Data on colorectal EMR training are limited. We aimed to evaluate the en bloc EMR rate of polyps ≤ 20 mm among advanced endoscopy trainees and to identify predictors of failed en bloc EMR. Methods This was a multicenter prospective study evaluating trainee performance in EMR during advanced endoscopy fellowship. A logistic regression model was used to identify the number of procedures and lesion cut-off size associated with an en bloc EMR rate of ≥ 80 %. Multivariate analysis was performed to identify predictors of failed en bloc EMR. Results Six trainees from six centers performed 189 colorectal EMRs, of which 104 (55 %) were for polyps ≤ 20 mm. Of these, 57.7 % (60/104) were resected en bloc. Trainees with ≥ 30 EMRs (OR 6.80; 95 % CI: 2.80–16.50; P = 0.00001) and lesions ≤ 17 mm (OR 4.56;95 CI:1.23–16.88; P = 0.02) were more likely to be associated with an en bloc EMR rate of ≥ 80 %. Independent predictors of failed en bloc EMR on multivariate analysis included: larger polyp size (OR:6.83;95 % CI:2.55–18.4; P = 0.0001), right colon location (OR:7.15; 95 % CI:1.31–38.9; P = 0.02), increased procedural difficulty (OR 2.99; 95 % CI:1.13–7.91; P = 0.03), and having performed < 30 EMRs (OR: 4.87; 95 %CI: 1.05–22.61; P = 0.04). Conclusions In this pilot study, we demonstrated that a relatively low proportion of trainees achieved en bloc EMR for polyps ≤ 20 mm and identified procedure volume and lesion size thresholds for successful en bloc EMR and independent predictors for failed en bloc resection. These preliminary results support the need for future efforts to define EMR procedure competence thresholds during training.
Volumetric laser endomicroscopy features of dysplasia at the gastric cardia in Barrett’s oesophagus: results from an observational cohort study
Trindade, Arvind J. , Raphael, Kara L. , Inamdar, Sumant , Stewart, Molly , Berkowitz, Joshua, Vegesna, Anil K. , McKinley, Matthew , Benias, Petros C. , Leggett, Cadman L. , Lee, Calvin , Sejpal, Divyesh V., Rishi, Arvind , Kahn, Allon , Trindade, Arvind J , Leggett, Cadman L

BMJ Open Gastroenterology | October 24, 2019 | Volume: 6 | Issue: 1 | Pages: e000340

10.1136/bmjgast-2019-000340 Get It

Objective Volumetric laser endomicroscopy (VLE) is an advanced imaging modality used in Barrett’s oesophagus (BE) to help identify dysplasia in the oesophagus. VLE criteria exist for oesophageal dysplasia but not for dysplasia in the gastric cardia. The aim of this study was to determine if there are in vivo VLE features that can predict gastric cardia dysplasia in BE. Design This was a single-centre observational cohort study from August 2016 to August 2018. Patients were included if they had BE, were undergoing a VLE exam as standard of care, and had a suspicious target laser marked at the gastric cardia. The following VLE features were correlated to histology to determine if an association existed between histology subtype and VLE feature: wide crypts, irregular surface, one large isolated gland, multiple glands, and complex glands. Results A total of 110 in vivo gastric cardia targets in 77 patients with BE were analysed. The following abnormalities were identified: 61 wide crypts, 34 isolated glands, 16 irregular surfaces, 15 multiple glands, and 11 complex glands. Complex glands were the only VLE feature that correlated to any histology subtype. They were present in 71% of targets with high-grade dysplasia (HGD), T1a cancer or T1b cancer and had a sensitivity, specificity, and accuracy of 71%, 99%, and 85%, respectively. Of the 10 patients with complex glands on VLE and HGD/cancer on histology, 4 had a normal-appearing mucosa (40%) on endoscopy. Conclusion Identification of complex glands on VLE may aid in detection of HGD or early cancer in the gastric cardia in BE. This is particularly important, as dysplasia at the gastric cardia can be difficult to see endoscopically.
863 Single-Use Duodenoscope for Endoscopic Retrograde Cholangiopancreatography: Performance Ratings From a Case Series of 60 Patients
Muthusamy, V. Raman , Bruno, Marco J. , Petersen, Bret T. , Sejpal, Divyesh V., Slivka, Adam, Peetermans, Joyce , Rousseau, Matthew , Tirrell, Gregory Philip, Ross, Andrew S., Kozarek, Richard A. , Petersen, Bret T. , Pleskow, Douglas K.

American Journal of Gastroenterology | October 8, 2019 | Volume: 114 | Issue: 1 | Pages: S501-S501

10.14309/01.ajg.0000592988.58172.47 Get It

INTRODUCTION: Exogenous transmission of infection via duodenoscope cross-contamination after failed disinfection is a preventable risk. Inadequate reprocessing of reusable duodenoscopes can occur. Given this possibility, a new single-use duodenoscope was recently developed. It had comparable performance to reusable duodenoscopes when tested by expert endoscopists in a comparative bench model for endoscopic retrograde cholangiopancreatography (ERCP). We subsequently aimed to assess the performance of this disposable duodenoscope in a series of human cases. METHODS: Six academic medical centers enrolled consecutive adults 18 years or older without altered pancreaticobiliary anatomy scheduled for an ERCP. Seven ERCP experts rated the new EXALT single-use Model D duodenoscope (Boston Scientific, Marlborough, MA; ClinicalTrials.gov NCT03701958) in ERCP procedures for Overall Satisfaction on a scale of 1 (unsatisfied) to 10 (very satisfied), “Not preferred/Neutral/Preferred” compared to reusable duodenoscopes on 23 ERCP maneuvers, and Qualitative Comparison of 17 performance characteristics on a scale of 1 (not preferred) to 5 (comparable to reusable duodenoscopes). RESULTS: Sixty consecutive patients had an ERCP using the first-generation single-use duodenoscope in April and May 2019. Thirty-seven (61.7%) were male, mean age was 64.4 years, and 44 (73.3%) had a prior ERCP at baseline. All 60 ERCP procedures were successfully performed, 58 (96.7%) with the single-use duodenoscope alone and 2 (3.3%) with crossover to a reusable duodenoscope. Median overall satisfaction with the single-use duodenoscope was rated 9.0 (range 1-10). The overall satisfaction rating was ≥ 7 in 56 (93.3%) ERCPs. All three ratings were at or above midpoint (Overall satisfaction ≥ 5, Comparative ERCP maneuver “Neutral/Preferred,” Qualitative Comparative rating of performance characteristic 3-5) in 47 (78.3%) cases. Four ERCPs had low (≤4) overall satisfaction ratings attributed to inadequate pushability of instruments due to suboptimal positioning of the duodenoscope in front of the papilla; these ERCPs were a subset in which biliary or pancreatic duct strictures were dilated and/or stented. CONCLUSION: Expert endoscopists reported good overall performance of a new single-use duodenoscope in a broad array of cases. Low ratings occurred rarely and were associated with particular ERCP maneuvers. Detailed design improvements to the single-use duodenoscope are underway.
Volumetric laser endomicroscopy and its application to Barrett's esophagus: results from a 1,000 patient registry
Smith, Michael S. , Konda, Vani J. , Gordon, Stuart R. , DeMeester, Steven R. , Joshi, Vivek , Ganguly, Eric K. , Mashimo, Hiroshi , Jobe, Blair A. , McKinley, Matthew , Wallace, Michael B. , Thakkar, Shyam , Schnoll‐Sussman, Felice , Sharaiha, Reem Z. , Tarnasky, P, Wolfsen, Herbert C. , Hawes, Robert H. , Lipham, John C. , Khara, Harshit S. , Navaneethan, U, Kedia, Prashant , Hasan, Muhammad K. , Sethi, Amrita , Samarasena, Jason , Siddiqui, Uzma D. , Gress, Frank G., Rodríguez, Reynaldo , Lee, C, Gonda, Tamas A. , Waxman, Irving , Hyder, S., Poneros, John M., Sharzehi, Kaveh , Palma, Jack A. Di, Sejpal, Divyesh V., Hagen, J. A., Rothstein, Richard, Sawhney, Mandeep , Malik, Zubair , Chang, Kenneth J. , Fichera, Alessandro , Gaidhane, Monica , Wallace, Michael B , Cash, Brooks D. , Trindade, Arvind J. , Diehl, David L. , Singh, Satish K. , Komatsu, Y, Kahaleh, Michel , Pleskow, Douglas K. , Hyder, S, Oh, Daniel S. , Berzin, Tyler M.

Diseases of the Esophagus | April 30, 2019 | Volume: 32 | Issue: 9 | Pages: No page available

10.1093/dote/doz029 Get It

SUMMARY Volumetric laser endomicroscopy (VLE) uses optical coherence tomography (OCT) for real-time, microscopic cross-sectional imaging. A US-based multi-center registry was constructed to prospectively collect data on patients undergoing upper endoscopy during which a VLE scan was performed. The objective of this registry was to determine usage patterns of VLE in clinical practice and to estimate quantitative and qualitative performance metrics as they are applied to Barrett's esophagus (BE) management. All procedures utilized the NvisionVLE Imaging System (NinePoint Medical, Bedford, MA) which was used by investigators to identify the tissue types present, along with focal areas of concern. Following the VLE procedure, investigators were asked to answer six key questions regarding how VLE impacted each case. Statistical analyses including neoplasia diagnostic yield improvement using VLE was performed. One thousand patients were enrolled across 18 US trial sites from August 2014 through April 2016. In patients with previously diagnosed or suspected BE (894/1000), investigators used VLE and identified areas of concern not seen on white light endoscopy (WLE) in 59% of the procedures. VLE imaging also guided tissue acquisition and treatment in 71% and 54% of procedures, respectively. VLE as an adjunct modality improved the neoplasia diagnostic yield by 55% beyond the standard of care practice. In patients with no prior history of therapy, and without visual findings from other technologies, VLE-guided tissue acquisition increased neoplasia detection over random biopsies by 700%. Registry investigators reported that VLE improved the BE management process when used as an adjunct tissue acquisition and treatment guidance tool. The ability of VLE to image large segments of the esophagus with microscopic cross-sectional detail may provide additional benefits including higher yield biopsies and more efficient tissue acquisition. Clinicaltrials.gov NCT02215291
Correction: Learning curve and competence for volumetric laser endomicroscopy in Barrett’s esophagus using cumulative sum analysis
Inamdar, Sumant , Smith, Michael S. , Rosen, Lisa, Han, Dennis , Chang, Kenneth J. , Leggett, Cadman, Lightdale, Charles J. , Sejpal, Divyesh V., Tearney, Guillermo J. , Thomas, Rebecca, Wallace, Michael B. , Leggett, Cadman L. , Wallace, Michael B , Leggett, Cadman L , Trindade, Arvind J. , Pleskow, Douglas K.

Endoscopy | July 27, 2018 | Volume: 50 | Issue: 05 | Pages: C10-C10

10.1055/a-0658-2867 Get It

Use of volumetric laser endomicroscopy for determining candidates for endoscopic therapy in superficial esophageal squamous cell carcinoma
Trindade, Arvind J. , Benias, Petros C. , Inamdar, Sumant , Fan, Cathy, Sethi, Amrita , Fukami, Norio , Andalib, Iman , Sejpal, Divyesh V., Rishi, Arvind , Kahn, Allon , Trindade, Arvind J , Fukami, Norio , Kahaleh, Michel

United European Gastroenterology Journal | February 23, 2018 | Volume: 6 | Issue: 6 | Pages: 838-845

10.1177/2050640618761701 Get It

BackgroundAccurate staging of superficial esophageal squamous cell cancer (ESCC) for endoscopic therapy is challenging. Optical coherence tomography (OCT) has been shown to be superior to high‐resolution endoscopic ultrasound (EUS). Volumetric Laser Endomicroscopy (VLE), a second‐generation OCT, has recently become commercially available.ObjectiveTo assess if VLE can determine which patients with superficial ESSC can undergo endoscopic therapy.MethodsThis is a multi‐center retrospective study. Patients were included if (a) they had visible ESCC, (b) they underwent VLE and EUS for staging, and c) if superficial disease was suspected then endoscopic resection had to be performed to have accurate histology to compare the VLE scan to. VLE scans were then compared to the gold standard: histology for superficial disease and EUS for disease T1b and greater.ResultsSeventeen patients were included with the following disease: squamous intraepithelial neoplasia (4 patients), T1a disease (6 patients), T1b (2 patients), T2 disease (2 patients) and T3 disease (3 patients). VLE was able to distinguish superficial disease, defined as disease limited up to the lamina propria, from non‐superficial disease in all cases.ConclusionsVLE may be able to determine which ESCC patients are candidates for endoscopic therapy. Prospective studies are needed to confirm this.
Learning curve and competence for volumetric laser endomicroscopy in Barrett’s esophagus using cumulative sum analysis
Inamdar, Sumant , Smith, Michael S. , Rosen, Lisa, Han, Dennis , Chang, Kenneth J. , Leggett, Cadman, Lightdale, Charles J. , Sejpal, Divyesh V., Tearney, Guillermo J. , Thomas, Rebecca, Wallace, Michael B. , Leggett, Cadman L. , Wallace, Michael B , Trindade, Arvind J. , Pleskow, Douglas K. , Leggett, Cadman L

Endoscopy | November 27, 2017 | Volume: 50 | Issue: 05 | Pages: 471-478

10.1055/s-0043-121569 Get It

Abstract Background and study aims Little is known about the learning curve for image interpretation in volumetric laser endomicroscopy (VLE) in Barrett’s esophagus (BE). The goal of this study was to calculate the learning curve, competence of image interpretation, sensitivity, specificity, and accuracy of VLE among novice users. Methods 31 novice users viewed 96 VLE images electronically at three academic institutions after a brief training session. There were 24 images of each histologic type: normal gastric cardia, normal esophageal squamous epithelium, non-neoplastic BE, and neoplastic BE. The users were asked to identify the correct tissue type and level of confidence. The cumulative summation (CUSUM) technique was used to construct a learning curve. Results 22 (71 %) of the physicians achieved VLE interpretation competency during their 96-slide review. Half of the physicians achieved competency at 65 images (95 % confidence interval [CI] 45 – 85). There was a statistically significant association between confidence in diagnosis and selecting the correct histologic tissue type (P < 0.001). The median accuracy for esophageal squamous epithelium, normal gastric cardia, non-neoplastic BE, and neoplastic BE was 96 % (95 %CI 95 % – 96 %), 95 % (95 %CI 94 % – 96 %), 90 % (95 %CI 88 % – 91 %), 96 % (95 %CI 95 % – 96 %). The overall accuracy was 95 % (95 %CI 93 % – 95 %). Conclusion The majority of novice users achieved competence in image interpretation of VLE for BE, using a pre-selected image set, with a favorable learning curve after a brief training session. An electronic review of VLE images, prior to real-time use of VLE, is encouraged.
Interobserver Agreement for Single Operator Choledochoscopy Imaging: Can We Do Better?
Sethi, Amrita , Doukides, Theodore , Sejpal, Divyesh V., Pleskow, Douglas K. , Slivka, Adam, Itoi, Takao , Petersen, Bret T. , Gress, Frank G., Gaidhane, Monica , Kahaleh, Michel , Kahaleh, Michel , Adler, Douglas G. , Shah, Raj J. , Edmundowicz, Steven A. , Petersen, Bret T. , Pleskow, Douglas

Diagnostic and Therapeutic Endoscopy | October 8, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-4

10.1155/2014/730731 Get It

Background. The SpyGlass Direct Visualization System (Boston Scientific, Natick, MA) is routinely used during single operator choledochoscopy (SOC) to identify biliary lesions or strictures with a diagnostic accuracy up to 88%. The objective of this study was to determine the interobserver agreement (IOA) of modified scoring criteria for diagnosing biliary lesions/strictures. Methods. 27 SPY SOC video clips were reviewed and scored by 9 interventional endoscopists based on published criteria that included the presence and severity of surface structure, vasculature visualization, lesions, and findings. Results. Overall IOA was “slight” for all variables. The K statistics are as follows: surface (K=0.12, SE = 0.02); vessels (K=0.14, SE = 0.02); lesions (K=0.11, SE = 0.02); findings (K=0.08, SE = 0.03); and final diagnosis (K=0.08, SE = 0.02). The IOA for “findings” and “final diagnosis” was also only “slight.” The final diagnosis was malignant (11), benign (11), and indeterminate (5). Conclusion. IOA using the modified criteria of SOC images was slight to almost poor. The average accuracy was less than 50%. These findings reaffirm that imaging criteria for benign and malignant biliary pathology need to be formally established and validated.