Back to Authors

Muthusamy, V. Raman

https://orcid.org/0000-0003-1602-1335

Mayo Clinic

University of California, Los Angeles

Citations 5

S702 Risk-Aligned Management Guided by the Tissue Systems Pathology Test Can Improve Health Outcomes in Barrett’s Esophagus and Reduce Healthcare-Associated Costs
Das, Ananya , Kamboj, Amrit K. , Smolko, Christian , Gorospe, Emmanuel C., Critchley-Thorne, Rebecca J. , Muthusamy, V. Raman, Leggett, Cadman L. , Arora, Meenakshi, Muthusamy, V. Raman

American Journal of Gastroenterology | October 24, 2024 | Volume: 119 | Issue: 10S | Pages: S486-S487

10.14309/01.ajg.0001032176.13634.ab Get It

Global prospective case series of ERCPs using a single-use duodenoscope
Bruno, Marco J. , Beyna, Torsten , Carr‐Locke, David L. , Chahal, Prabhleen , Costamagna, Guido , Devereaux, Benedict , Giovannini, Marc, Khor, Christopher , Lau, James Y., May, Gary R. , Muthusamy, V. Raman , Petersen, Bret T. , Raijman, Isaac , Reddy, D. Nageshwar , Ross, Andrew S., Sejpal, Divyesh V., Sherman, Stuart , Siddiqui, Uzma D. , Ziady, Christopher, Peetermans, Joyce , Rousseau, Matthew , Slivka, Adam, Group, EXALT Single-use Duodenoscope Study, Fichera, Alessandro , Pleskow, Douglas , Goenka, Mahesh Kumar , Patel, Sandeep , Petersen, Bret T. , Pleskow, Douglas K. , Repici, Alessandro , Group, EXALT Single-use Duodenoscope Study

Endoscopy | July 18, 2023 | Volume: 55 | Issue: 12 | Pages: 1103-1114

10.1055/a-2131-7180 Get It

Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3–4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.
The American Foregut Society White Paper on the Endoscopic Classification of Esophagogastric Junction Integrity
Nguyen, Ninh T. , Chang, Kenneth J. , Lipham, John C. , Dayyeh, Barham Abu, Wilson, Erik B., Muthusamy, V. Raman, Bell, Reginald , Janu, Peter , Runge, Ava , Thosani, Nirav C , Canto, Marcia Irene , Muthusamy, V. Raman , Clarke, John O. , Swanström, Lee L. , Kahrilas, Peter J.

Foregut: The Journal of the American Foregut Society | September 29, 2022 | Volume: 2 | Issue: 4 | Pages: 339-348

10.1177/26345161221126961 Get It

Background: The American Foregut Society (AFS) is dedicated to advancing patient care and digestive health within the realm of foregut disease. One of the most common and debilitating esophageal conditions is gastroesophageal reflux disease (GERD). The Hill grade is an endoscopic classification of the esophagogastric junction (EGJ) based on the appearance of the gastroesophageal flap valve from a retroflexed view of the hiatus. This endoscopic classification provides insight into the anatomic disruption of the EGJ which has been shown to correlate with GERD. However, clinical utilization of this classification by endoscopists has been limited due to the perceived relevance and subjectivity of the classification. With the advent of endoscopic treatment options for GERD, there is renewed enthusiasm to develop a grading system of the EGJ that can objectively define anatomical impairment and reduce interobserver grading variability. Methods: The AFS convened a 13-member working group tasked with reviewing the Hill grade classification and formulating a proposal for its revision utilizing a modified Delphi method. This white paper summarizes the output from this working group. Results: The working group concluded that all components of the antireflux barrier—the lower esophageal sphincter and its sling fibers, the crural diaphragm, and the gastroesophageal flap valve—contribute to EGJ integrity. Using defined objective parameters of extent of hiatal axial herniation and crural disruption and presence or absence of a flap valve, the new AFS classification stratifies EGJ integrity from normal (grade 1) to increasing degrees of EGJ disruption (grade 2-4) beginning with loss of the flap valve and progressing to increasing degrees of crural disruption and hiatus hernia. This AFS classification also stipulates appropriate endoscopic methodology to utilize in making the assessment and provides a basic nomenclature for communication among endoscopists. Conclusions: The AFS endoscopic classification of the EGJ expands on the Hill classification by including assessment of axial hiatal hernia length (L), hiatal aperture diameter (D), and presence or absence of the flap valve (F) making it more comprehensive - LDF components. Future directions include validation studies correlating the ability of the AFS classification in predicting the presence and severity of GERD.
Recovery of endoscopy services in the era of COVID-19: recommendations from an international Delphi consensus
Bhandari, Pradeep , Subramaniam, Sharmila , Bourke, Michael J. , Alkandari, Asma , Brown, J F , Keswani, Rajesh N. , Bisschops, Raf , Hassan, Cesare , Raju, Gottumukkala S. , Muthusamy, V. Raman , Sethi, Amrita , May, Gary R. , Bruno, Marco J. , Alkhatry, Maryam, Almadi, Majid A. , Ibrahim, Mostafa , Moura, Eduardo Guimarães Hourneaux de , Navarrete, Claudio , Wulfson, Adolfo, Khor, Christopher , Ponnudurai, Ryan , Inoue, Haruhiro , Yahagi, Naohisa , Yu, Honggang , Maydeo, Amit , Reddy, D. Nageshwar , Wallace, Michael B. , Pochapin, Mark , Repici, Alessandro , Chiu, Philip Wai Yan , Hassan, Cesare , Yu, Honggang , Rösch, Thomas , Bisschops, Raf , Wallace, Michael B , de Moura, Eduardo , Albéniz, Eduardo , Kaminski, Michal Filip , Emura, Fabian , Saito, Yutaka , Kashin, Sergey V. , Nikonov, Evgeniy L. , Sharma, Prateek

Gut | August 14, 2020 | Volume: 69 | Issue: 11 | Pages: 1915-1924

10.1136/gutjnl-2020-322329 Get It

The COVID-19 pandemic has had a profound impact on provision of endoscopy services globally as staff and real estate were repurposed. As we begin to recover from the pandemic, a cohesive international approach is needed, and guidance on how to resume endoscopy services safely to avoid unintended harm from diagnostic delays. The aim of these guidelines is to provide consensus recommendations that clinicians can use to facilitate the swift and safe resumption of endoscopy services. An evidence-based literature review was carried out on the various strategies used globally to manage endoscopy during the COVID-19 pandemic and control infection. A modified Delphi process involving international endoscopy experts was used to agree on the consensus statements. A threshold of 80% agreement was used to establish consensus for each statement. 27 of 30 statements achieved consensus after two rounds of voting by 34 experts. The statements were categorised as pre-endoscopy, during endoscopy and postendoscopy addressing relevant areas of practice, such as screening, personal protective equipment, appropriate environments for endoscopy and infection control precautions, particularly in areas of high disease prevalence. Recommendations for testing of patients and for healthcare workers, appropriate locations of donning and doffing areas and social distancing measures before endoscopy are unique and not dealt with by any other guidelines. This international consensus using a modified Delphi method to produce a series of best practice recommendations to aid the safe resumption of endoscopy services globally in the era of COVID-19.
863 Single-Use Duodenoscope for Endoscopic Retrograde Cholangiopancreatography: Performance Ratings From a Case Series of 60 Patients
Muthusamy, V. Raman , Bruno, Marco J. , Petersen, Bret T. , Sejpal, Divyesh V., Slivka, Adam, Peetermans, Joyce , Rousseau, Matthew , Tirrell, Gregory Philip, Ross, Andrew S., Kozarek, Richard A. , Petersen, Bret T. , Pleskow, Douglas K.

American Journal of Gastroenterology | October 8, 2019 | Volume: 114 | Issue: 1 | Pages: S501-S501

10.14309/01.ajg.0000592988.58172.47 Get It

INTRODUCTION: Exogenous transmission of infection via duodenoscope cross-contamination after failed disinfection is a preventable risk. Inadequate reprocessing of reusable duodenoscopes can occur. Given this possibility, a new single-use duodenoscope was recently developed. It had comparable performance to reusable duodenoscopes when tested by expert endoscopists in a comparative bench model for endoscopic retrograde cholangiopancreatography (ERCP). We subsequently aimed to assess the performance of this disposable duodenoscope in a series of human cases. METHODS: Six academic medical centers enrolled consecutive adults 18 years or older without altered pancreaticobiliary anatomy scheduled for an ERCP. Seven ERCP experts rated the new EXALT single-use Model D duodenoscope (Boston Scientific, Marlborough, MA; ClinicalTrials.gov NCT03701958) in ERCP procedures for Overall Satisfaction on a scale of 1 (unsatisfied) to 10 (very satisfied), “Not preferred/Neutral/Preferred” compared to reusable duodenoscopes on 23 ERCP maneuvers, and Qualitative Comparison of 17 performance characteristics on a scale of 1 (not preferred) to 5 (comparable to reusable duodenoscopes). RESULTS: Sixty consecutive patients had an ERCP using the first-generation single-use duodenoscope in April and May 2019. Thirty-seven (61.7%) were male, mean age was 64.4 years, and 44 (73.3%) had a prior ERCP at baseline. All 60 ERCP procedures were successfully performed, 58 (96.7%) with the single-use duodenoscope alone and 2 (3.3%) with crossover to a reusable duodenoscope. Median overall satisfaction with the single-use duodenoscope was rated 9.0 (range 1-10). The overall satisfaction rating was ≥ 7 in 56 (93.3%) ERCPs. All three ratings were at or above midpoint (Overall satisfaction ≥ 5, Comparative ERCP maneuver “Neutral/Preferred,” Qualitative Comparative rating of performance characteristic 3-5) in 47 (78.3%) cases. Four ERCPs had low (≤4) overall satisfaction ratings attributed to inadequate pushability of instruments due to suboptimal positioning of the duodenoscope in front of the papilla; these ERCPs were a subset in which biliary or pancreatic duct strictures were dilated and/or stented. CONCLUSION: Expert endoscopists reported good overall performance of a new single-use duodenoscope in a broad array of cases. Low ratings occurred rarely and were associated with particular ERCP maneuvers. Detailed design improvements to the single-use duodenoscope are underway.