Recent guidelines on biliary cannulation are lacking. This guideline is an initiative of the World Endoscopy Organization (WEO) with the involvement of a panel of experts from Asia, Europe, and America. Relevant clinical questions on four areas (post‐endoscopic retrograde cholangiopancreatography [ERCP] pancreatitis [PEP] prophylaxis, biliary cannulation techniques, sphincterotomy/papillary balloon dilation, and biliary cannulation in special circumstances) were developed and answered after systematic reviews of the literature and using the Grading of Recommendations Assessment, Development, and Evaluation methodology. Successful biliary cannulation and sphincterotomy are cornerstones of ERCP and are indispensable for almost all therapeutic and advanced diagnostic procedures. However, adverse events, particularly PEP, may commonly occur and impair patients' outcomes. A high cannulation rate and a low rate of PEP are quality indicators for ERCP and should be the goal of all endoscopists. With this guideline we aimed to provide clinical practice advice applicable worldwide, regardless of resources and expertise availability. The main recommendations focus on specific aspects of ERCP, including pre‐, intra‐, and postprocedural measures to reduce the risk of PEP, the technique for an initial biliary cannulation attempt, options for cannulation in cases of difficult biliary access, alternatives to ERCP in case of failure (percutaneous‐ and endoscopic ultrasound‐guided), and biliary access in altered anatomy (periampullary diverticulum and postsurgical anatomy) and in the presence of duodenal stenosis.
Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
Pure cut vs. Endocut in endoscopic biliary sphincterotomy: Systematic review and meta-analysis of randomized clinical trials
Abstract Background and study aims Biliary sphincterotomy is a crucial step in endoscopic retrograde cholangiopancreatography (ERCP), a procedure known to carry a 5% to 10% risk of complications. The relationship between Pure cut, Endocut, post-ERCP pancreatitis (PEP) and bleeding is unclear. This systematic review and meta-analysis compared these two current types and their relationships with adverse events. Patients and methods This systematic review involved searching articles in multiple databases until August 2023 comparing pure cut versus Endocut in biliary sphincterotomy. The meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Results A total of 987 patients from four randomized controlled trials were included. Overall pancreatitis: A higher risk of pancreatitis was found in the Endocut group than in the Pure cut group (P=0.001, RD=0.04 [range, 0.01 to 0.06]; I2=29%). Overall immediate bleeding: Statistical significance was found to favor Endocut, (P=0.05; RD=–0.15 [range, –0.29 to –0.00]; I2=93%). No statistical significance between current modes was found in immediate bleeding without endoscopic intervention (P=0.10; RD=–0.13 [range, –0.29 to 0.02]; I2=88%), immediate bleeding with endoscopic intervention (P=0.06; RD=–0.07 [range, –0.14 to 0.00]; I2=76%), delayed bleeding (P=0.40; RD=0.01 [range, –0.02 to 0.05]; I2=72%), zipper cut (P=0.58; RD=–0.03 [range, –0.16 to 0.09]; I2=97%), perforation (P=1.00; RD=0.00 [range, –0.01 to 0.01]; I2=0%) and cholangitis (P=0.77; RD=0.00 [range, –0.01 to 0.02]; I2=29%). Conclusions The available data in the literature show that Endocut carries an increased risk for PEP and does not prevent delayed or clinically significant bleeding, although it prevents intraprocedural bleeding. Based on such findings, Pure cut should be the preferred electric current mode for biliary sphincterotomy.
Endoscopic transoral outlet reduction induces enterohormonal changes in patients with weight regain after Roux-en-Y gastric bypass
Abstract Background and study aims Transoral outlet reduction (TORe) has long been employed in treating weight regain after Roux-en-Y gastric bypass. However, its impact on gut hormones and their relationship with weight loss remains unknown. Patients and methods This was a substudy of a previous randomized clinical trial. Adults with significant weight regain and dilated gastrojejunostomy underwent TORe with argon plasma coagulation (APC) alone or APC plus endoscopic suturing (APC-suture). Serum levels of ghrelin, GLP-1, and PYY were assessed at fasting, 30, 60, 90, and 120 minutes after a standardized liquid meal. Results were compared according to allocation group, clinical success, and history of cholecystectomy. Results Thirty-six patients (19 APC vs. 17 APC-suture) were enrolled. There were no significant baseline differences between groups. In all analyses, the typical postprandial decrease in ghrelin levels was delayed by 30 minutes, but no other changes were noted. GLP-1 levels significantly decreased at 12 months in both allocation groups. Similar findings were noted after dividing groups according to the history of cholecystectomy and clinical success. The APC cohort presented an increase in PYY levels at 90 minutes, while the APC-suture group did not. Naïve patients had significantly lower PYY levels at baseline (P = 0.01) compared with cholecystectomized individuals. This latter group experienced a significant increase in area under the curve (AUC) for PYY levels, while naïve patients did not, leading to a higher AUC at 12 months (P = 0.0001). Conclusions TORe interferes with the dynamics of gut hormones. APC triggers a more pronounced enteroendocrine response than APC-suture, especially in cholecystectomized patients.
Establishing Standards for Gastrointestinal Endoscopic-Related Fluoroscopy: An International Expert Consensus Using a Modified Delphi Process
Abstract Background and study aims Significant weight regain affects up to one-third of patients after Roux-en-Y gastric bypass (RYGB) and demands treatment. Transoral outlet reduction (TORe) with argon plasma coagulation (APC) alone or APC plus full-thickness suturing TORe (APC-FTS) is effective in the short term. However, no study has investigated the course of gastrojejunostomy (GJ) or quality of life (QOL) data after the first post-procedure year. Patients and methods Patients eligible for a 36-month follow-up visit after TORe underwent upper gastrointestinal endoscopy with measurement of the GJ and answered QOL questionnaires (RAND-36). The primary aim was to evaluate the long-term outcomes of TORe, including weight loss, QOL, and GJ anastomosis (GJA) size. Comparisons between APC and APC-FTS TORe were a secondary aim. Results Among 39 eligible patients, 29 returned for the 3-year follow-up visit. There were no significant differences in demographics between APC and APC-FTS TORe groups. At 3 years, patients from both groups regained all the weight lost at 12 months, and the GJ diameter was similar to the pre-procedure assessment. As to QOL, most improvements seen at 12 months were lost at 3 years, returning to pre-procedure levels. Only the energy/fatigue domain improvement was kept between the 1- and 3-year visits. Conclusions Obesity is a chronic relapsing disease. Most effects of TORe are lost at 3 years, and redilation of the GJA occurs. Therefore, TORe should be considered iterative rather than a one-off procedure.
Recovery of endoscopy services in the era of COVID-19: recommendations from an international Delphi consensus
The COVID-19 pandemic has had a profound impact on provision of endoscopy services globally as staff and real estate were repurposed. As we begin to recover from the pandemic, a cohesive international approach is needed, and guidance on how to resume endoscopy services safely to avoid unintended harm from diagnostic delays. The aim of these guidelines is to provide consensus recommendations that clinicians can use to facilitate the swift and safe resumption of endoscopy services. An evidence-based literature review was carried out on the various strategies used globally to manage endoscopy during the COVID-19 pandemic and control infection. A modified Delphi process involving international endoscopy experts was used to agree on the consensus statements. A threshold of 80% agreement was used to establish consensus for each statement. 27 of 30 statements achieved consensus after two rounds of voting by 34 experts. The statements were categorised as pre-endoscopy, during endoscopy and postendoscopy addressing relevant areas of practice, such as screening, personal protective equipment, appropriate environments for endoscopy and infection control precautions, particularly in areas of high disease prevalence. Recommendations for testing of patients and for healthcare workers, appropriate locations of donning and doffing areas and social distancing measures before endoscopy are unique and not dealt with by any other guidelines. This international consensus using a modified Delphi method to produce a series of best practice recommendations to aid the safe resumption of endoscopy services globally in the era of COVID-19.