Back to Authors

Kahaleh, Michel

https://orcid.org/0000-0003-0836-6114

Mayo Clinic

Rutgers, The State University of New Jersey

Citations 9

Computer‐aided detection for esophageal achalasia (with video)
Shiwaku, Hironari , Misawa, Masashi , Inoue, Haruhiro , Boškoski, Ivo , Shimamura, Yuto , Ikebuchi, Yuichiro , Ominami, Masaki , Htet, Hein , Messmann, H, Colosso, Bianca Maria Quarta , Repici, Alessandro , Stavropoulos, Stavros N. , Bechara, Robert , Sethi, Amrita, Beyna, Torsten , Santi, Esperanza Grace , Sharma, Prateek , Eleftheriadis, Nikolas, Minami, Hitomi, Haber, Gregory , Seewald, Stefan , Shiwaku, Akio, Shiwaku, Yoshiyuki, Mori, Kensaku, Costamagna, Guido , Shimamura, Yuto , Ikebuchi, Yuichiro , Iwaya, Yugo , Htet, Hein Myat Thu , Colosso, Bianca Maria Quarta , Bechara, Robert , Kahaleh, Michel , Beyna, Torsten , Jiang, Kai, Oda, Masahiro , Familiari, Pietro , Hayee, Bu , Ho, Khek Yu , So, Jimmy Bok Yan , Bhandari, Pradeep , Grimes, Kevin L. , Maselli, Roberta , Hassan, Cesare , Fukami, Norio , Kahaleh, Michel , Sethi, Amrita , Neuhaus, Horst Ekkehard , Chiu, Philip Wai Yan , Eleftheriadis, Nikolas, Draganov, Peter V. , Mori, Kensaku , Kudo, Shin‐ei , Hasegawa, Suguru

Digestive Endoscopy | June 12, 2025 | Volume: 37 | Issue: 8 | Pages: 851-861

10.1111/den.15028 Get It

ObjectivesAchalasia is an esophageal motility disorder that impairs quality of life and is often missed (20–50%) on endoscopy. A newly developed computer‐aided detection (CAD) software has shown high accuracy for achalasia diagnosis in preclinical settings. However, its benefit in a clinical setting remains unclear.MethodsBetween February and August 2023, 83 endoscopists from 27 centers assessed 50 randomized endoscopic videos (25 achalasia, 25 nonachalasia) without and with CAD. Endoscopists assessed videos without CAD, then with CAD after 2 months. The primary end‐point was improvement in sensitivity for nonexperienced endoscopists (no endoscopic experience of achalasia). Sensitivity, specificity, and accuracy with and without CAD were compared using the McNemar test.ResultsSensitivity for diagnosing achalasia increased significantly with CAD, rising from 74.2% (95% confidence interval [CI] 72.2–76.0%) to 91.2% (95% CI 89.9–92.4%) for all readers, showing a difference of 17.1% (95% CI 15.1–19.0%). Specifically, sensitivity improved from 66.9% (95% CI 63.6–70.0%) to 91.9% (95% CI 89.9–93.6%) among nonexperienced endoscopists, resulting in a difference of 25.0% (95% CI 21.7–28.4%), and from 79.5% (95% CI 77.1–81.8%) to 90.8% (95% CI 89.0–92.3%) among experienced endoscopists (endoscopic experience of at least one achalasia case), with a difference of 11.3% (95% CI 8.9–13.6%). Accuracy and specificity improved significantly with CAD assistance, regardless of reader's experience.ConclusionCAD improves achalasia detection by 17%, confirming preclinical results. The benefit was higher for nonexperienced endoscopists. CAD assistance may lead to prompt and effective treatment, minimizing the risk of false‐negative diagnosis in clinical practice.Trial registrationThis study was registered in the University Hospital Medical Information Network Clinical Trial Registry (https://www.umin.ac.jp/ctr/) number: UMIN000053047.
Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Khalaf, Kareem , Pawlak, Katarzyna M. , Alkandari, Asma , Baron, Todd H. , Bechara, Robert , Binda, Cecilia , Chen, Yen‐I , Moura, Eduardo Guimarães Hourneaux de , Forbes, Nauzer , James, Paul, Martin, Harry , May, Gary R. , Mosko, Jeffrey D. , Oyeleke, Ganiyat K. , Petersen, Bret T. , Saxena, Payal , Sethi, Amrita , Sharaiha, Reem Z. , Tang, Raymond S. , Villarroel, Mariano , Hooft, Jeanin E. van , Renteln, Daniel von , Walsh, Catharine M. , Aberin, Tricia, Banavage, Dawn, Chen, Jowell Akina, Clancy, James, Drake, Heather, Im, Melanie, Low, Chooi Peng, Myszko, Alexandra, Navarro, Krista, Redman, Jessica, Reyes, Wayne, Weinstein, Faina, Na, Caleb, Tham, Daniel , He, Tony , Malipatil, Sharan B., Gimpaya, Nikko , Kundra, Arjun , Grover, Samir C. , Barkun, Alan N , Bechara, Robert , Binda, Cecilia , de Moura, Eduardo , Hassan, Cesare , Kahaleh, Michel , Sharaiha, Reem Z , Villarroel, Mariano , van Hooft, Jeanin E , Voermans, Rogier P , von Renteln, Daniel , Walsh, Catharine M , Gupta, Sunil , Fujiyoshi, Yusuke , Grover, Samir C , Causada Calo, Natalia S , Pawlak, Katarzyna M , Adler, Douglas G. , Barkun, Alan , Berzin, Tyler M. , Cai, Ming‐Yan , Carrara, Silvia , Fugazza, Alessandro , Hassan, Cesare , James, Paul D., Kahaleh, Michel , Maselli, Roberta , Repici, Alessandro , Spadaccini, Marco , Teshima, Christopher , Voermans, Rogier P. , Clancy, James, Reyes, Wayne, Gupta, Sunil , Mokhtar, Ahmed H., Gholami, Reza

Endoscopy International Open | October 7, 2024 | Volume: 12 | Issue: 11 | Pages: E1315-E1325

10.1055/a-2427-3893 Get It

Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
First interobserver agreement of optical coherence tomography in the bile duct: A multicenter collaborative study
Tyberg, Amy , Raijman, Isaac , Sarkar, Avik , Samarasena, Jason , Andalib, Iman , Diehl, David L. , Pleskow, Douglas K. , Woods, Kevin E. , Gordon, Stuart R. , Pannala, Rahul , Kedia, Prashant , Tarnasky, Paul R., Sejpal, Divyesh V., Kumta, Nikhil A. , Parasher, Gulshan , Adler, Douglas G., Patel, Kalpesh, Siddiqui, Uzma D. , Joshi, Viren, Pleskow, Douglas , Gaidhane, Monica , Trindade, Arvind J. , Shahid, Haroon M. , Draganov, Peter V. , Adler, Douglas G. , Yang, Dennis J. , Kahaleh, Michel , Joshi, Viren

Endoscopy International Open | March 23, 2022 | Volume: 10 | Issue: 08 | Pages: E1065-E1072

10.1055/a-1779-5027 Get It

Abstract Background and study aims Optical coherence tomography (OCT) is a new technology available for evaluation of indeterminate biliary strictures. It allows under-the-surface visualization and preliminary studies have confirmed standardized characteristics associated with malignancy. The aim of this study is to evaluate the first interobserver agreement in identifying previously agreed upon OCT criteria and diagnosing of malignant versus benign disease. Patients and methods Fourteen endoscopists were asked to review an atlas of reference clips and images of eight criteria derived from expert consensus A total of 35 de-identified video clips were then evaluated for presence of the eight criteria and for final diagnosis of malignant versus benign using the atlas as reference Intraclass correlation (ICC) analysis was done to evaluate interrater agreement. Results Clips of 23 malignant lesions and 12 benign lesions were scored. Excellent interobserver agreement was seen with dilated hypo-reflective structures (0.85) and layering effacement (0.89); hyper-glandular mucosa (0.76), intact layering (0.81), and onion-skin layering (0.77); fair agreement was seen with scalloping (0.58), and thickened epithelium (0.4); poor agreement was seen with hyper-reflective surface (0.36). The diagnostic ICC for both neoplastic (0.8) and non-neoplastic (0.8) was excellent interobserver agreement. The overall diagnostic accuracy was 51 %, ranging from 43 % to 60 %. Conclusions Biliary OCT is a promising new modality for evaluation of indeterminate biliary strictures. Interobserver agreement ranged from fair to almost perfect on eight previously identified criteria. Interobserver agreement for malignancy diagnosis was substantial (0.8). Further studies are needed to validate this data.
Volumetric laser endomicroscopy and its application to Barrett's esophagus: results from a 1,000 patient registry
Smith, Michael S. , Konda, Vani J. , Gordon, Stuart R. , DeMeester, Steven R. , Joshi, Vivek , Ganguly, Eric K. , Mashimo, Hiroshi , Jobe, Blair A. , McKinley, Matthew , Wallace, Michael B. , Thakkar, Shyam , Schnoll‐Sussman, Felice , Sharaiha, Reem Z. , Tarnasky, P, Wolfsen, Herbert C. , Hawes, Robert H. , Lipham, John C. , Khara, Harshit S. , Navaneethan, U, Kedia, Prashant , Hasan, Muhammad K. , Sethi, Amrita , Samarasena, Jason , Siddiqui, Uzma D. , Gress, Frank G., Rodríguez, Reynaldo , Lee, C, Gonda, Tamas A. , Waxman, Irving , Hyder, S., Poneros, John M., Sharzehi, Kaveh , Palma, Jack A. Di, Sejpal, Divyesh V., Hagen, J. A., Rothstein, Richard, Sawhney, Mandeep , Malik, Zubair , Chang, Kenneth J. , Fichera, Alessandro , Gaidhane, Monica , Wallace, Michael B , Cash, Brooks D. , Trindade, Arvind J. , Diehl, David L. , Singh, Satish K. , Komatsu, Y, Kahaleh, Michel , Pleskow, Douglas K. , Hyder, S, Oh, Daniel S. , Berzin, Tyler M.

Diseases of the Esophagus | April 30, 2019 | Volume: 32 | Issue: 9 | Pages: No page available

10.1093/dote/doz029 Get It

SUMMARY Volumetric laser endomicroscopy (VLE) uses optical coherence tomography (OCT) for real-time, microscopic cross-sectional imaging. A US-based multi-center registry was constructed to prospectively collect data on patients undergoing upper endoscopy during which a VLE scan was performed. The objective of this registry was to determine usage patterns of VLE in clinical practice and to estimate quantitative and qualitative performance metrics as they are applied to Barrett's esophagus (BE) management. All procedures utilized the NvisionVLE Imaging System (NinePoint Medical, Bedford, MA) which was used by investigators to identify the tissue types present, along with focal areas of concern. Following the VLE procedure, investigators were asked to answer six key questions regarding how VLE impacted each case. Statistical analyses including neoplasia diagnostic yield improvement using VLE was performed. One thousand patients were enrolled across 18 US trial sites from August 2014 through April 2016. In patients with previously diagnosed or suspected BE (894/1000), investigators used VLE and identified areas of concern not seen on white light endoscopy (WLE) in 59% of the procedures. VLE imaging also guided tissue acquisition and treatment in 71% and 54% of procedures, respectively. VLE as an adjunct modality improved the neoplasia diagnostic yield by 55% beyond the standard of care practice. In patients with no prior history of therapy, and without visual findings from other technologies, VLE-guided tissue acquisition increased neoplasia detection over random biopsies by 700%. Registry investigators reported that VLE improved the BE management process when used as an adjunct tissue acquisition and treatment guidance tool. The ability of VLE to image large segments of the esophagus with microscopic cross-sectional detail may provide additional benefits including higher yield biopsies and more efficient tissue acquisition. Clinicaltrials.gov NCT02215291
Use of volumetric laser endomicroscopy for determining candidates for endoscopic therapy in superficial esophageal squamous cell carcinoma
Trindade, Arvind J. , Benias, Petros C. , Inamdar, Sumant , Fan, Cathy, Sethi, Amrita , Fukami, Norio , Andalib, Iman , Sejpal, Divyesh V., Rishi, Arvind , Kahn, Allon , Trindade, Arvind J , Fukami, Norio , Kahaleh, Michel

United European Gastroenterology Journal | February 23, 2018 | Volume: 6 | Issue: 6 | Pages: 838-845

10.1177/2050640618761701 Get It

BackgroundAccurate staging of superficial esophageal squamous cell cancer (ESCC) for endoscopic therapy is challenging. Optical coherence tomography (OCT) has been shown to be superior to high‐resolution endoscopic ultrasound (EUS). Volumetric Laser Endomicroscopy (VLE), a second‐generation OCT, has recently become commercially available.ObjectiveTo assess if VLE can determine which patients with superficial ESSC can undergo endoscopic therapy.MethodsThis is a multi‐center retrospective study. Patients were included if (a) they had visible ESCC, (b) they underwent VLE and EUS for staging, and c) if superficial disease was suspected then endoscopic resection had to be performed to have accurate histology to compare the VLE scan to. VLE scans were then compared to the gold standard: histology for superficial disease and EUS for disease T1b and greater.ResultsSeventeen patients were included with the following disease: squamous intraepithelial neoplasia (4 patients), T1a disease (6 patients), T1b (2 patients), T2 disease (2 patients) and T3 disease (3 patients). VLE was able to distinguish superficial disease, defined as disease limited up to the lamina propria, from non‐superficial disease in all cases.ConclusionsVLE may be able to determine which ESCC patients are candidates for endoscopic therapy. Prospective studies are needed to confirm this.
Use of probe‐based confocal laser endomicroscopy (pCLE) in gastrointestinal applications. A consensus report based on clinical evidence
Wang, Kenneth K. , Carr‐Locke, David L. , Singh, Satish K. , Neumann, Helmut , Bertani, Helga , Galmiche, Jean-Paul, Arsenescu, Razvan, Caillol, Fabrice , Chang, Kenneth J. , Chaussade, Stanislas, Coron, Emmanuel , Dlugosz, Aldona , Gan, S. Ian , Giovannini, Marc, Gress, Frank G., Haluszka, Oleh, Kahaleh, Michel , Konda, Vani J. , Prat, Frédéric, Sharma, Prateek , Slivka, Adam, Wolfsen, Herbert C. , Zfass, Alvin M., Costamagna, Guido , Ho, Khek Yu , Shah, Raj J. , Kahaleh, Michel

United European Gastroenterology Journal | January 14, 2015 | Volume: 3 | Issue: 3 | Pages: 230-254

10.1177/2050640614566066 Get It

Background Probe‐based confocal laser endomicroscopy (pCLE) provides microscopic imaging during an endoscopic procedure. Its introduction as a standard modality in gastroenterology has brought significant progress in management strategies, affecting many aspects of clinical care and requiring standardisation of practice and training. Objective This study aimed to provide guidance on the standardisation of its practice and training in Barrett's oesophagus, biliary strictures, colorectal lesions and inflammatory bowel diseases. Methods Initial statements were developed by five group leaders, based on the available clinical evidence. These statements were then voted and edited by the 26 participants, using a modified Delphi approach. After two rounds of votes, statements were validated if the threshold of agreement was higher than 75%. Results Twenty‐six experts participated and, among a total of 77 statements, 61 were adopted (79%) and 16 were rejected (21%). The adoption of each statement was justified by the grade of evidence. Conclusion pCLE should be used to enhance the diagnostic arsenal in the evaluation of these indications, by providing microscopic information which improves the diagnostic performance of the physician. In order actually to implement this technology in the clinical routine, and to ensure good practice, standardised initial and continuing institutional training programmes should be established.
Interobserver Agreement for Single Operator Choledochoscopy Imaging: Can We Do Better?
Sethi, Amrita , Doukides, Theodore , Sejpal, Divyesh V., Pleskow, Douglas K. , Slivka, Adam, Itoi, Takao , Petersen, Bret T. , Gress, Frank G., Gaidhane, Monica , Kahaleh, Michel , Kahaleh, Michel , Adler, Douglas G. , Shah, Raj J. , Edmundowicz, Steven A. , Petersen, Bret T. , Pleskow, Douglas

Diagnostic and Therapeutic Endoscopy | October 8, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-4

10.1155/2014/730731 Get It

Background. The SpyGlass Direct Visualization System (Boston Scientific, Natick, MA) is routinely used during single operator choledochoscopy (SOC) to identify biliary lesions or strictures with a diagnostic accuracy up to 88%. The objective of this study was to determine the interobserver agreement (IOA) of modified scoring criteria for diagnosing biliary lesions/strictures. Methods. 27 SPY SOC video clips were reviewed and scored by 9 interventional endoscopists based on published criteria that included the presence and severity of surface structure, vasculature visualization, lesions, and findings. Results. Overall IOA was “slight” for all variables. The K statistics are as follows: surface (K=0.12, SE = 0.02); vessels (K=0.14, SE = 0.02); lesions (K=0.11, SE = 0.02); findings (K=0.08, SE = 0.03); and final diagnosis (K=0.08, SE = 0.02). The IOA for “findings” and “final diagnosis” was also only “slight.” The final diagnosis was malignant (11), benign (11), and indeterminate (5). Conclusion. IOA using the modified criteria of SOC images was slight to almost poor. The average accuracy was less than 50%. These findings reaffirm that imaging criteria for benign and malignant biliary pathology need to be formally established and validated.
A Multicenter, Prospective Study of a New Fully Covered Expandable Metal Biliary Stent for the Palliative Treatment of Malignant Bile Duct Obstruction
Petersen, Bret T. , Kahaleh, Michel , Kozarek, Richard A. , Loren, David E. , Gupta, Kapil , Kowalski, Thomas E., Freeman, Martin L. , Chen, Yang K., Branch, M. Stanley, Edmundowicz, Steven A. , Glück, Michael , Binmoeller, Kenneth F., Baron, Todd H. , Kinney, Timothy P., Ross, William A., Jowell, Paul S., Carr‐Locke, David L. , Shah, Raj J. , Kahaleh, Michel , Edmundowicz, Steven A

Gastroenterology Research and Practice | March 27, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-7

10.1155/2013/642428 Get It

Background and Study Aims. Endoscopic placement of self-expanding metal stents (SEMSs) is indicated for palliation of inoperable malignant biliary obstruction. A fully covered biliary SEMS (WallFlex Biliary RX Boston Scientific, Natick, USA) was assessed for palliation of extrahepatic malignant biliary obstruction.Patients and Methods. 58 patients were included in this prospective, multicenter series conducted under an FDA-approved IDE. Main outcome measurements included (1) absence of stent occlusion within six months or until death, whichever occurred first and (2) technical success, need for reintervention, bilirubin levels, stent patency, time to stent occlusion, and adverse events.Results. Technical success was achieved in 98% (57/58), with demonstrated acute removability in two patients. Adequate clinical palliation until completion of followup was achievedin 98% (54/55) ofevaluablepatients, with 1 reintervention due to stent obstruction after 142 days. Mean total bilirubin decreased from 8.9 mg/dL to 1.2 mg/dL at 1 month. Device-related adverse events were limited and included 2 cases of cholecystitis. One stent migrated following radiation therapy.Conclusions. The WallFlex Biliary fully covered stent yielded technically successful placement with uncomplicated acute removal where required, appropriate reduction in bilirubin levels, and low rates of stent migration and occlusion. This SEMS allows successful palliation of malignant extrahepatic biliary obstruction.