Back to Authors

Seewald, Stefan

https://orcid.org/0000-0001-8520-5918

Mayo Clinic

Klinik Hirslanden

Citations 3

Computer‐aided detection for esophageal achalasia (with video)
Shiwaku, Hironari , Misawa, Masashi , Inoue, Haruhiro , Boškoski, Ivo , Shimamura, Yuto , Ikebuchi, Yuichiro , Ominami, Masaki , Htet, Hein , Messmann, H, Colosso, Bianca Maria Quarta , Repici, Alessandro , Stavropoulos, Stavros N. , Bechara, Robert , Sethi, Amrita, Beyna, Torsten , Santi, Esperanza Grace , Sharma, Prateek , Eleftheriadis, Nikolas, Minami, Hitomi, Haber, Gregory , Seewald, Stefan , Shiwaku, Akio, Shiwaku, Yoshiyuki, Mori, Kensaku, Costamagna, Guido , Shimamura, Yuto , Ikebuchi, Yuichiro , Iwaya, Yugo , Htet, Hein Myat Thu , Colosso, Bianca Maria Quarta , Bechara, Robert , Kahaleh, Michel , Beyna, Torsten , Jiang, Kai, Oda, Masahiro , Familiari, Pietro , Hayee, Bu , Ho, Khek Yu , So, Jimmy Bok Yan , Bhandari, Pradeep , Grimes, Kevin L. , Maselli, Roberta , Hassan, Cesare , Fukami, Norio , Kahaleh, Michel , Sethi, Amrita , Neuhaus, Horst Ekkehard , Chiu, Philip Wai Yan , Eleftheriadis, Nikolas, Draganov, Peter V. , Mori, Kensaku , Kudo, Shin‐ei , Hasegawa, Suguru

Digestive Endoscopy | June 12, 2025 | Volume: 37 | Issue: 8 | Pages: 851-861

10.1111/den.15028 Get It

ObjectivesAchalasia is an esophageal motility disorder that impairs quality of life and is often missed (20–50%) on endoscopy. A newly developed computer‐aided detection (CAD) software has shown high accuracy for achalasia diagnosis in preclinical settings. However, its benefit in a clinical setting remains unclear.MethodsBetween February and August 2023, 83 endoscopists from 27 centers assessed 50 randomized endoscopic videos (25 achalasia, 25 nonachalasia) without and with CAD. Endoscopists assessed videos without CAD, then with CAD after 2 months. The primary end‐point was improvement in sensitivity for nonexperienced endoscopists (no endoscopic experience of achalasia). Sensitivity, specificity, and accuracy with and without CAD were compared using the McNemar test.ResultsSensitivity for diagnosing achalasia increased significantly with CAD, rising from 74.2% (95% confidence interval [CI] 72.2–76.0%) to 91.2% (95% CI 89.9–92.4%) for all readers, showing a difference of 17.1% (95% CI 15.1–19.0%). Specifically, sensitivity improved from 66.9% (95% CI 63.6–70.0%) to 91.9% (95% CI 89.9–93.6%) among nonexperienced endoscopists, resulting in a difference of 25.0% (95% CI 21.7–28.4%), and from 79.5% (95% CI 77.1–81.8%) to 90.8% (95% CI 89.0–92.3%) among experienced endoscopists (endoscopic experience of at least one achalasia case), with a difference of 11.3% (95% CI 8.9–13.6%). Accuracy and specificity improved significantly with CAD assistance, regardless of reader's experience.ConclusionCAD improves achalasia detection by 17%, confirming preclinical results. The benefit was higher for nonexperienced endoscopists. CAD assistance may lead to prompt and effective treatment, minimizing the risk of false‐negative diagnosis in clinical practice.Trial registrationThis study was registered in the University Hospital Medical Information Network Clinical Trial Registry (https://www.umin.ac.jp/ctr/) number: UMIN000053047.
Full-thickness resection device (FTRD) for treatment of upper gastrointestinal tract lesions: the first international experience
Khashab, Mouen A., Sharaiha, Reem Z. , Hajifathalian, Kaveh , Ichkhanian, Yervant , Dawod, Qais, Schmidt, Arthur , Glaser, Nicholas, Vosoughi, Kia , Templeton, Adam W. , Samarasena, Jason , Chehade, Nabil El Hage , Lee, John G., Chang, Kenneth J. , Mizrahi, Meir, Barawi, Mohammed, Irani, Shayan , Friedland, Shai , Korc, Paul , Aadam, A. Aziz , Kowalski, Thomas E., Smallfield, George , Ginsberg, Gregory G. , Kumta, Nikhil A. , Tang, Shou-jiang, Naga, Yehia M. , Amateau, Stuart K. , Kasmin, Franklin, Goetz, Martin , Seewald, Stefan , Kumbhari, Vivek , Ngamruengphong, Saowanee , Mahdev, Srihari, Mukewar, Saurabh , Sampath, Kartik, Carr‐Locke, David L. , Khashab, Mouen A. , Meining, Alexander , Diehl, David L. , Grimm, Ian S. , James, Theodore , Al‐Haddad, Mohammad , Fukami, Norio , Lajin, Michael

Endoscopy International Open | September 22, 2020 | Volume: 08 | Issue: 10 | Pages: E1291-E1301

10.1055/a-1216-1439 Get It

Abstract Background and study aims The Full-Thickness Resection Device (FTRD) provides a novel treatment option for lesions not amenable to conventional endoscopic resection techniques. There are limited data on the efficacy and safety of FTRD for resection of upper gastrointestinal tract (GIT) lesions. Patients and methods This was an international multicenter retrospective study, including patients who had an endoscopic resection of an upper GIT lesion using the FTRD between January 2017 and February 2019. Results Fifty-six patients from 13 centers were included. The most common lesions were mesenchymal neoplasms (n = 23, 41 %), adenomas (n = 7, 13 %), and hamartomas (n = 6, 11 %). Eighty-four percent of lesions were located in the stomach, and 14 % in the duodenum. The average size of lesions was 14 mm (range 3 to 33 mm). Deployment of the FTRD was technically successful in 93 % of patients (n = 52) leading to complete and partial resection in 43 (77 %) and 9 (16 %) patients, respectively. Overall, the FTRD led to negative histological margins (R0 resection) in 38 (68 %) of patients. A total of 12 (21 %) mild or moderate adverse events (AEs) were reported. Follow-up endoscopy was performed in 31 patients (55 %), on average 88 days after the procedure (IQR 68–138 days). Of these, 30 patients (97 %) did not have any residual or recurrent lesion on endoscopic examination and biopsy, with residual adenoma in one patient (3 %). Conclusions Our results suggest a high technical success rate and an acceptable histologically complete resection rate, with a low risk of AEs and early recurrence for FTRD resection of upper GIT lesions.