Acute cholecystitis affects ∼200,000 individuals annually in the United States, with laparoscopic cholecystectomy as the gold standard treatment. However, in high-risk surgical candidates, alternative drainage methods are necessary. Percutaneous transhepatic gallbladder drainage (PT-GBD) has traditionally served as the primary alternative intervention, offering rapid decompression, but is limited by a negative impact on the patient’s quality of life, the risk of long-term or even permanent tube placement, adverse events, and high recurrence rates. Endoscopic approaches, such as endoscopic transpapillary gallbladder drainage (ET-GBD) and, more recently, endoscopic ultrasound-guided gallbladder drainage (EUS-GBD), have emerged as viable alternatives to PT-GBD. EUS-GBD, first introduced in 2007, offers technical and clinical outcomes comparable to PT-GBD with fewer adverse events, shorter hospital stays, and lower rates of recurrence. The introduction of lumen-apposing metal stents (LAMS) has revolutionized EUS-GBD, simplifying deployment and enabling subsequent internal gallbladder access, which allows additional interventions such as cholecystoscopy and stone removal. EUS-GBD is now supported by international guidelines, and 1 device has achieved FDA approval for the management of acute cholecystitis in nonsurgical candidates. Proper patient selection is essential, guided by multidisciplinary evaluation, with EUS-GBD contraindicated in specific scenarios such as gallbladder perforation, coagulopathy, and large-volume ascites. Technical considerations include choice of access site (transgastric versus transduodenal), stent type, and procedural route [direct (freehand) or wire-guided]. Postprocedural care and stent management remain variable and nonstandardized. Emerging data suggest that interval cholecystectomy can still be performed safely after EUS-GBD. As adoption of EUS-GBD with LAMS expands, structured training and standardization of practice are crucial to optimizing outcomes.
Endoscopic Ultrasound-guided Transluminal Gallbladder Drainage in Patients With Acute Cholecystitis
Objective: To evaluate the safety and efficacy of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) using a lumen-apposing metal stent (LAMS). Background: For patients with acute cholecystitis who are poor surgical candidates, EUS-GBD using a LAMS is an important treatment alternative to percutaneous gallbladder drainage. Methods: We conducted a regulatory-compliant, prospective multicenter trial at 7 tertiary referral centers in the United States of America and Belgium. Thirty consecutive patients with mild or moderate acute cholecystitis who were not candidates for cholecystectomy were enrolled between September 2019 and August 2021. Eligible patients had a LAMS placed transmurally with 30 to 60-day indwell if removal was clinically indicated, and 30-day follow-up post-LAMS removal. Endpoints included days until acute cholecystitis resolution, reintervention rate, acute cholecystitis recurrence rate, and procedure-related adverse events (AEs). Results: Technical success was 93.3% (28/30) for LAMS placement and 100% for LAMS removal in 19 patients for whom removal was attempted. Five (16.7%) patients required reintervention. Mean time to acute cholecystitis resolution was 1.6±1.5 days. Acute cholecystitis symptoms recurred in 10.0% (3/30) after LAMS removal. Five (16.7%) patients died from unrelated causes. Procedure-related AEs were reported to the FDA in 30.0% (9/30) of patients, including one fatal event 21 days after LAMS removal; however, no AEs were causally related to the LAMS. Conclusions: For selected patients with acute cholecystitis who are at elevated surgical risk, EUS-GBD with LAMS is an alternative to percutaneous gallbladder drainage. It has high technical and clinical success, with low recurrence and an acceptable AE rate. Clinicaltrials.gov, Number: NCT03767881.
Outcomes of peroral endoscopic myotomy in patients with achalasia and prior bariatric surgery: A multicenter experience
Summary Peroral endoscopic myotomy (POEM) in patients with achalasia who are status post bariatric surgery may be technically challenging due to postsurgical scarring and altered anatomy. The aim of the study was to assess the efficacy and safety of POEM for achalasia in patients with prior bariatric surgery. A review of prospectively maintained databases at three tertiary referral centers from January 2015 to January 2021 was performed. The primary outcome of interest was clinical success, defined as a post-treatment Eckardt score ≤ 3 or improvement in Eckardt score by ≥ 1 when the baseline score was <3, and improvement of symptoms. Secondary outcomes were adverse event rates and symptom recurrence. Sixteen patients status post Roux-en-Y gastric bypass (n = 14) and sleeve gastrectomy (n = 2) met inclusion criteria. Indications for POEM were achalasia type I (n = 2), type II (n = 9), and type III (n = 5). POEM was performed either by anterior or posterior approach. The pre-POEM mean integrated relaxation pressure was 26.2 ± 7.6 mm Hg. The mean total myotomy length was 10.2 ± 2.7 cm. The mean length of hospitalization was 1.4 ± 0.7 days. Pre- and postprocedure Eckardt scores were 6.1 ± 2.1 and 1.7 ± 1.8, respectively. The overall clinical success rate was 93.8% (15/16) with mean follow-up duration of 15.5 months. One patient had esophageal leak on postprocedure esophagram and managed endoscopically. Dysphagia recurred in two patients, which was successfully managed with pneumatic dilation with or without botulinum toxin injection. POEM appears to be safe and effective in the management of patients with achalasia who have undergone prior bariatric surgery.
Effectiveness and Safety of EUS Rendezvous After Failed Biliary Cannulation With ERCP
Background: Endoscopic ultrasound–guided rendezvous (EUS-RV) endoscopic retrograde cholangiopancreatography (ERCP) is an alternative to interventional radiology–guided rendezvous ERCP in patients who failed biliary cannulation with conventional ERCP. However, there is significant variation in reported rates of success and adverse events associated with EUS-RV-assisted ERCP. We performed a systematic review and a proportion meta-analysis to reliably assess the effectiveness and safety of the EUS-RV-assisted ERCP. Materials and Methods: We conducted a comprehensive search of multiple electronic databases and conference proceedings (from inception through August 2020) to identify studies reporting EUS-RV-assisted ERCP in patients who failed biliary cannulation with conventional ERCP techniques. Using the random-effects model described by DerSimonian and Laird, we calculated the pooled rates of technical success, clinical success, and adverse events of EUS-RV-assisted ERCP. Results: Twelve studies reporting a total of 342 patients were included in the meta-analysis. The pooled rate of technical success (12 studies reporting a total of 342 patients) was 86.1% [95% confidence interval (CI): 78.4-91.3]. The pooled rate of clinical success (4 studies reporting a total of 94 patients) was 80.8% (95% CI: 64.1-90.8). The pooled rate of overall adverse events (12 studies; 42 events in 342 patients) was 14% (95% CI: 10.5-18.4). Low to moderate heterogeneity was noted in the analyses. Conclusions: EUS-RV-assisted ERCP appears to be effective and safe in patients who failed biliary cannulation with conventional ERCP. Given the risk of adverse events, it should be performed in centers with expertise in therapeutic endoscopic ultrasound.
Full-thickness resection device (FTRD) for treatment of upper gastrointestinal tract lesions: the first international experience
Abstract Background and study aims The Full-Thickness Resection Device (FTRD) provides a novel treatment option for lesions not amenable to conventional endoscopic resection techniques. There are limited data on the efficacy and safety of FTRD for resection of upper gastrointestinal tract (GIT) lesions. Patients and methods This was an international multicenter retrospective study, including patients who had an endoscopic resection of an upper GIT lesion using the FTRD between January 2017 and February 2019. Results Fifty-six patients from 13 centers were included. The most common lesions were mesenchymal neoplasms (n = 23, 41 %), adenomas (n = 7, 13 %), and hamartomas (n = 6, 11 %). Eighty-four percent of lesions were located in the stomach, and 14 % in the duodenum. The average size of lesions was 14 mm (range 3 to 33 mm). Deployment of the FTRD was technically successful in 93 % of patients (n = 52) leading to complete and partial resection in 43 (77 %) and 9 (16 %) patients, respectively. Overall, the FTRD led to negative histological margins (R0 resection) in 38 (68 %) of patients. A total of 12 (21 %) mild or moderate adverse events (AEs) were reported. Follow-up endoscopy was performed in 31 patients (55 %), on average 88 days after the procedure (IQR 68–138 days). Of these, 30 patients (97 %) did not have any residual or recurrent lesion on endoscopic examination and biopsy, with residual adenoma in one patient (3 %). Conclusions Our results suggest a high technical success rate and an acceptable histologically complete resection rate, with a low risk of AEs and early recurrence for FTRD resection of upper GIT lesions.
ERCP with overtube-assisted enteroscopy in patients with Roux-en-Y gastric bypass anatomy: a systematic review and meta-analysis
AbstractBackground Endoscopic retrograde cholangiopancreatography (ERCP) in patients with Roux-en-Y gastric bypass (RYGB) anatomy is challenging. Overtube-assisted enteroscopy (OAE) is usually needed to perform ERCP in these patients. There is significant variation in the reported rates of success and adverse events across published studies. We performed a systematic review and meta-analysis to reliably estimate the pooled rates of success and adverse events.Methods We performed a systematic search of multiple electronic databases through February 2020 to identify studies reporting outcomes of OAE-ERCP in post-RYGB patients. The pooled rates of enteroscopy success, technical success, and adverse events were estimated for OAE-ERCP. The pooled rates of success and adverse events were also estimated for ERCP using double-balloon enteroscopes (DBE) alone.Results 10 studies reporting a total of 398 procedures were included in the meta-analysis. The pooled rates of enteroscopy and technical success of OAE-ERCP were 75.3 % (95 % confidence interval [CI] 64.5 – 83.6) and 64.8 % (95 %CI 53.1 – 74.9) respectively. The pooled rate of adverse events was 8.0 % (95 %CI 5.2 – 12.2). The pooled rates of enteroscopy and technical success of DBE-ERCP (four studies) were 83.5 % (95 %CI 68.3 – 92.2) and 72.5 % (95 %CI 52.3 – 86.4), respectively. The pooled rate of adverse events with DBE-ERCP was 9.0 % (95 %CI 5.4 – 14.5). Substantial heterogeneity was noted.Conclusions OAE-ERCP appears to be effective and safe in post-RYGB patients. Among the currently available techniques, OAE-ERCP is the least invasive approach in this challenging group of patients. Future studies comparing the effectiveness and safety of alternative novel techniques, such as endosonography-directed transgastric ERCP, with OAE-ERCP are needed.
Endoscopic treatment of nonstricture-related benign biliary diseases using covered self-expandable metal stents