Back to Authors

Ross, Andrew

https://orcid.org/0000-0003-2523-5431

Mayo Clinic

Virginia Mason Medical Center

Citations 3

Effectiveness and Safety of EUS Rendezvous After Failed Biliary Cannulation With ERCP
Klair, Jagpal S. , Zafar, Yousaf , Ashat, Munish , Bomman, Shivanand , Jayaraj, Mahendran , Law, Joanna K. , Larsen, Michael , Singh, Dhruv P. , Rustagi, Tarun , Irani, Shayan , Ross, Andrew , Kozarek, Richard A. , Krishnamoorthi, Rajesh , Murali, Arvind R.

Journal of Clinical Gastroenterology | April 9, 2021 | Volume: 57 | Issue: 2 | Pages: 211-217

10.1097/mcg.0000000000001543 Get It

Background: Endoscopic ultrasound–guided rendezvous (EUS-RV) endoscopic retrograde cholangiopancreatography (ERCP) is an alternative to interventional radiology–guided rendezvous ERCP in patients who failed biliary cannulation with conventional ERCP. However, there is significant variation in reported rates of success and adverse events associated with EUS-RV-assisted ERCP. We performed a systematic review and a proportion meta-analysis to reliably assess the effectiveness and safety of the EUS-RV-assisted ERCP. Materials and Methods: We conducted a comprehensive search of multiple electronic databases and conference proceedings (from inception through August 2020) to identify studies reporting EUS-RV-assisted ERCP in patients who failed biliary cannulation with conventional ERCP techniques. Using the random-effects model described by DerSimonian and Laird, we calculated the pooled rates of technical success, clinical success, and adverse events of EUS-RV-assisted ERCP. Results: Twelve studies reporting a total of 342 patients were included in the meta-analysis. The pooled rate of technical success (12 studies reporting a total of 342 patients) was 86.1% [95% confidence interval (CI): 78.4-91.3]. The pooled rate of clinical success (4 studies reporting a total of 94 patients) was 80.8% (95% CI: 64.1-90.8). The pooled rate of overall adverse events (12 studies; 42 events in 342 patients) was 14% (95% CI: 10.5-18.4). Low to moderate heterogeneity was noted in the analyses. Conclusions: EUS-RV-assisted ERCP appears to be effective and safe in patients who failed biliary cannulation with conventional ERCP. Given the risk of adverse events, it should be performed in centers with expertise in therapeutic endoscopic ultrasound.
Acute Pancreatitis Task Force on Quality: Development of Quality Indicators for Acute Pancreatitis Management
Vivian, Elaina , Cler, Leslie, Conwell, Darwin L. , Coté, Gregory A. , Dickerman, Richard, Freeman, Martin L. , Gardner, Timothy B. , Hawes, Robert H. , Kedia, Prashant , Krishnamoorthi, Rajesh , Oduor, Hellen , Ross, Andrew , Sethi, Amrita , Varadarajulu, Shyam , Vege, Santhi Swaroop , Wassef, Wahid , Wilcox, C. Mel, Yadav, Dhiraj , Ellison, Ashton , Habash, Samar, Rastegari, Sheila , Reddy, Rathan , Yen, Timothy , Tarnasky, Paul R., Pandol, Stephen J. , Papachristou, Georgios I. , Whitcomb, David C. , Wu, Bechien U. , Brooks, Mary Rachel

American Journal of Gastroenterology | June 14, 2019 | Volume: 114 | Issue: 8 | Pages: 1322-1342

10.14309/ajg.0000000000000264 Get It

INTRODUCTION: Detailed recommendations and guidelines for acute pancreatitis (AP) management currently exist. However, quality indicators (QIs) are required to measure performance in health care. The goal of the Acute Pancreatitis Task Force on Quality was to formally develop QIs for the management of patients with known or suspected AP using a modified version of the RAND/UCLA Appropriateness Methodology. METHODS: A multidisciplinary expert panel composed of physicians (gastroenterologists, hospitalists, and surgeons) who are acknowledged leaders in their specialties and who represent geographic and practice setting diversity was convened. A literature review was conducted, and a list of proposed QIs was developed. In 3 rounds, panelists reviewed literature, modified QIs, and rated them on the basis of scientific evidence, bias, interpretability, validity, necessity, and proposed performance targets. RESULTS: Supporting literature and a list of 71 proposed QIs across 10 AP domains (Diagnosis, Etiology, Initial Assessment and Risk Stratification, etc.) were sent to the expert panel to review and independently rate in round 1 (95% of panelists participated). Based on a round 2 face-to-face discussion of QIs (75% participation), 41 QIs were classified as valid. During round 3 (90% participation), panelists rated the 41 valid QIs for necessity and proposed performance thresholds. The final classification determined that 40 QIs were both valid and necessary. DISCUSSION: Hospitals and providers managing patients with known or suspected AP should ensure that patients receive high-quality care and desired outcomes according to current evidence-based best practices. This physician-led initiative formally developed 40 QIs and performance threshold targets for AP management. Validated QIs provide a dependable quantitative framework for health systems to monitor the quality of care provided to patients with known or suspected AP.
Endoscopic treatment of nonstricture-related benign biliary diseases using covered self-expandable metal stents
Irani, Shayan , Baron, Todd H. , Law, Ryan , Akbar, Ali, Ross, Andrew , Glück, Michael , Gan, S. Ian , Kozarek, Richard A. , Akbar, Ali

Endoscopy | December 19, 2014 | Volume: 47 | Issue: 04 | Pages: 315-321

10.1055/s-0034-1391093 Get It